----------------------------------------------------------------------- Wilcox Associates, Inc. PC-DMIS® Version 2010 Enterprise Metrology Solutions Installation Notes: ----------------------------------------------------------------------- 1) General System Requirements 2) Information about this release 3) New Product Information 4) Release Notes **************************************************************************** **************************************************************************** 1) General System Requirements Minimum Requirements:------------------------------------------------------- | | | • PC-DMIS® 2010 operates under 32-bit and 64-bit (x64) WindowsXP®; | | 32-bit and 64-bit Vista; and 32-bit and 64-bit Windows 7. | | No other operating systems are supported. | | • Pentium-IV or higher processor is suggested. | | • 2 GHZ XEON or Intel processor. | | • 2 GB of RAM is recommended but significantly more may be required if | | working with large CAD models. | | • 1 GB of free hard drive space minimum for the application. | | • SVGA capable monitor. | | • DVD drive. | | • USB port available. | | • The computer must have a graphics card that supports OpenGL shading. | | We cannot specify an exact graphics card since every user has varying | | needs. However, nVidia is the preferred graphics vendor for PC-DMIS. | | • Nvidia GeForce video cards are not recommended for use with PC-DMIS. | | This is defined as a "gaming" card according to Nvidia Engineering. | | • Supports a screen resolution of 1280 x 1024 or higher. | | • RTF file output requires Microsoft Word to be viewed. | | • Microsoft® .NET 3.5. | | | --------------------------------------------------------------------------- Recommended Minimums:------------------------------------------------------- | | | • PC-DMIS® 2010 operates under 32-bit and 64-bit (x64) WindowsXP®; | | 32-bit and 64-bit Vista; and 32-bit and 64-bit Windows 7. | | No other operating systems are supported. | | • 2 GHZ or higher Duo-Core processor for improved performance. | | • 4 GB of RAM or higher. More RAM may be required if working with large | | CAD models. You should have RAM equal to 8 times the size of the | | largest CAD file you will use. (For example, if you use an IGES model | | of 250 MB, then 2 GB RAM is recommended.) | | • 2 GB of free hard drive space plus allocated Virtual Memory of 8 times | | the largest CAD file used. | | • SVGA graphics card that supports OpenGL shading and that has WHQL | | certified drivers. On board video card memory should be based on the | | size of CAD file being used. | | • For use without CAD models, 64MB video memory. | | • For small to medium CAD files (50-100 MB), 128 MB video memory. | | • For large CAD files (> 100 MB), 256 MB+ video memory. | | WHQL (Microsoft Windows Hardware Quality Labs) video drivers can be | | downloaded automatically when using the Windows Update software. | | • SVGA capable monitor. | | • DVD drive. | | • 2 USB ports available. | | | --------------------------------------------------------------------------- • NOTE: Depending on your specific needs, the recommended system specifications for this version of PC-DMIS may be much higher. A more substantial computer system may be required to accommodate part programs using Automation or complex Reporting objects. Be sure to consult with your PC-DMIS distributor to find out the type of computer system you will need in order to run this software at its optimum capability. • IMPORTANT: When using 3rd-party drivers you should contact your local Hexagon representative to ensure Operating Sytem compatibility. • ANTI-VIRUS SOFTWARE: The Sophos® Anti-virus tool was used by Wilcox Associates Inc. while testing PC-DMIS. The performance of any other anti-virus tool will need to be confirmed by the user. (http://sophos.com/products/enterprise/endpoint/security-and-control/) • INSPECTION PLANNER: You may need to recreate the IPD file for needed parameters so imported Inspection Plan items are created correctly. **************************************************************************** **************************************************************************** 2) Information about this release. We at Wilcox Associates are proud to bring you this new version of PC-DMIS® 2010. This Enterprise Metrology Solutions platform brings together new aspects of PC-DMIS® for the development of a complete manufacturing process control solution. Available in this release are variations of PC-DMIS® designed to assist with every aspect of the fabrication and quality control process. The newly created packages include PC-DMIS® Laser, PC-DMIS® NC, as well as the established PC-DMIS® Pro, PC-DMIS® CAD, and PC-DMIS® CAD++ platforms. Also included with this release is PC-DMIS® ONE, a simplified shop-floor DCC inspection package developed in cooperation with Brown & Sharpe. The testing of this version has been significant. We’d like to take a moment to discuss this process and also make you aware of the various components of testing. Testing is comprised of two parts. These can be described as functional testing and integration testing. The vast majority of testing effort goes on in the functional area. This is the testing that determines that specific functions that are core to the software, regardless of what type of machine is used, are working correctly. The integration testing is essentially a testing of the interface with a particular type of machine. In the ideal scenario, WAI would have access to at least one of every piece of hardware that is operating in the field running PC-DMIS®. However, in practical terms, this is impossible. This integration test plan is then performed on as many types of machines as we have available. Unfortunately, there will inevitably be machines to which we do not have access and that cannot be fully tested in this manner. To this end we have made an effort at closing this gap by partnering with our customers through the Beta Test Program. On our web site you will find an application for this program here: http://www.wilcoxassoc.com/usersarea/beta_test_application.php We urge you to consider signing up for the program as it provides the mutual benefit of helping us create the best product possible for you, our customer. Should you experience problems with your system after installation of PC-DMIS® 2010, it could possibly be an integration problem. If it is a problem of this nature, it will probably be evident immediately upon first use of the possibly untested configuration. Should such a problem materialize, you will be given the highest priority for correcting these problems. Please call Tech Support immediately to report any integration problems. For existing users of PC-DMIS who currently have earlier versions of PC-DMIS® installed, it is advised that PC-DMIS® 2010 be installed into a new directory. In this way, you can be assured of continuous use of the existing version should problems arise with this newer version. **************************************************************************** **************************************************************************** 3) New Product Information (Note: EMS products remain in Early Adopter stage until formal release of each is announced.) • WAI Toolkit - Allows for the creation of custom commands in PC-DMIS Important 2D Distance Change: In PC-DMIS v2010 and later the 2D Distance dimension and the DIST2D expression have changed somewhat; they no longer use the workplane as part of the calculation when the third argument is set to a plane and the distance is being calculated perpendicular to the third argument (“perpendicular to” is always used by the DIST2D expression). See the "2D Distance" topic and the "Pointer Expressions" topic in the help file for more information. ---------------------------------------Major Enhancements--------------------------------------------- 1) Comments support media files 2) Clear Point Move 3) MOVE/POINT in 1 or 2 Axes 4) User Interface Improvements 5) XML Export 6) Reset Tips 7) Clip laser data horizontally and vertically (Laser) 8) CAD Groups 9) Image Capture (Vision) 10) Total Station Support (Portable) 11) Fast Probe Mode 12) Y14.5 2009 GD&T Support: - Bidirectional Positional Tolerancing - Unequal Tolerance Zones - Square Area Symbol 13) ScanShark V4i and V5 Scanner Support on Romer (Cimcore) Infinite Series Arms ****************************************************************************************************** ****************************************************************************************************** ****************************************************************************************************** ****************************************************************************************************** 4) Release Notes Version 2010 of PC-DMIS is a significant development release of the software. Initial Release Date: March 03, 2010 **** Prior to the release of Version 2010, Version 2009 was last official release of PC-DMIS by Wilcox Associates, Inc. and the Brown & Sharpe Metrology Group of Hexagon Metrology. **** NOTE: Enhancements listed below are listed with the most recent set of changes on top. ------------------- Technical Preview 3 Updates (March 02, 2010) ------------------- 104694 - Upgrade Datakit to new version v6.1. 105100 - Implement Tip Size Averaging option for Probe Setup 105786 - Need to expose some settings through the product UI in probe setup 105992 - Draw Leader Lines for each point on graphical analysis with Point Info Label at End. 106036 - Create the F9 dialog to go with thse new command 106165 - Enable snap grid when grid is hidden 106250 - Add ability to make the graphical analysis view back ground transparent 106409 - GA of profile analyses needs additional modifications and support 106458 - MMB, LMB (Maximum material boundary and Least material boundary) of datums for true position and profile 106459 - New Y14.5 flatness per unit 106460 - New Y14.5 (1994-2009) new circle-U symbol 106468 - Add Bidirectional True Position, Polar Coordinate Method (also 1994 standard) 106485 - PCDMIS interface for new UJB (Universal Jog Box) 106521 - ER 505915: Add Magnification and Illumination buttons to LIV toolbar 106522 - TESA - Add support for new Visio Jogbox on the VISIO 300GL 106547 - Need full support for FASTPRB (related to Enh# 502013) for standard (non-SP25) analog probes 106548 - Calibration enhancements to do used tips (Enh# 505485) 106549 - Need tip reset exposed to UI (Enh# 505483) 106561 - Snap to Grid changes per Audi 106566 - Implement the algrithm Audi provided to calculate point to insert. 106577 - Create a log file from the change manager 106579 - Add nominal line for graphical analysis reporting control 106587 - ER# 505498 : A move command to the safe (probe change) position. 106590 - When saving backwards insert unsupported commands inside a Comment command 106598 - Ford Europe: Offset for the point info label is required 106606 - MMB LMB (Maximum material boundary and Least material boundary) of datums for profile 106623 - Add Generic Feature support to change manager 106624 - Add new warning for eTOOL import 106625 - Add support to allow planner best fit construction features use in alignments 106627 - Add ability to highlight/unhighlight CAD features from the Edit Window 106658 - Support PEM extensions for ACR3 (Enh# 506048) 106663 - Add MeasBallCenter and TheoBallCenter properties to IContactPoint interface 106680 - Add Generic XML Output Function to PC-DMIS 106681 - Add XML .NET support into PC-DMIS 106689 - Add the custom command to the install and modify the resources/layouts to accomodate it 106690 - Make individual Perimeter Points and vectors visible even when the perimeter point dialog is closed 106710 - Need to allow access to reporting "Mods" via automation 106715 - Create a 35.16.20 horizontal machine with rotary table from the 3000_30-16-24 106726 - Create an icon for the menu item "Auto Insert" 106736 - Consolidate the find noms utilities into one 106743 - Add CAD select capabilites to the generic feature dialog 106752 - Remove the Option Password dialog if not needed 106753 - Implement the qualification procedure proposed by HMH 106785 - All vendor s'vision tips are shown in probe utility dlg when a vendor probe is selected. 106786 - Add support for IDS falcon and eagle framegrabbers 106787 - Reflex Vision: When starting PC-DMIS a new part program should be created 106794 - Turn CMS sphere qualification back on 106818 - Improve 8bit interface with analogue probe head (MPH) 106820 - Improve Contact probe toolbox pages for localization 106848 - Add to the ignore list the files that are automatically generated by building the NCPorojects 106860 - Support constructed features in PC-DMIS Change Manager 106864 - Installation at Husqvarna - Aycliffe UK 106870 - Add Move Coordinate Information to the Edit Window 106877 - Reflex Vision: Auto select LIV/CAD tabs based on gage window selection 106885 - Update calibration sequence for SCP600 changer type to allow them to be close together (Enh# 502733) 106916 - Add Toolkit DLLs to PC-DMIS installer 106917 - Add 2009 Traditional Chinese Help File into 2010 Install 106919 - NIST Enhancments 106922 - Add the 2009 Italian Core Help File into 2010 Install 106972 - Update TotalStationUIFiles 106973 - Add MeteoStation driver to TrackerUIFiles directory 106974 - Change tipdata strategy for I++ 106975 - Update LK-Direct interface according to the latest 106993 - Create UJB Install to be added to PC-DMIS install 106994 - Create Watchdog in UJB Utility 107068 - Debug manager for PCDMIS 2010 107085 - Add new TesastarMP_US component definitions to PROBE.DAT 107122 - Add the Czech 2009 Core Help File into 2010 Install 107127 - Add the 2009 Simplified Chinese Core Help File into 2010 Install 107128 - Add the German 2009 Core Help File into 2010 Install 107144 - Add Non-core Localized Helps into PC-DMIS 2010 Installs 107162 - Add the Portuguese 2009 Core Help File into 2010 Install 107168 - Add 2009 Swedish Core Help into 2010 Install 107179 - Upgrade Datakit libraries to v6.2 in 2010 258353 - Problems of precision with a double arm machine and long probe extensions. 259839 - SYSTEMS 4 UI : Report Label Properties dialog looks bad... 260092 - RunTime Error on Line: 770 -wrong number of arguments 261107 - The actual coordinate is wrong when the features have been patterned 261785 - Delete icon is visible when there is nothing to delete 262486 - Trying to multi select features in the new dimensioning/tolleranceing section (location dimensions) causes nominals to change 262509 - Cad window can't display the part model stably 262591 - Generating a DMO file from the attached PP makes PC-DMIS insert a blank space between the Dimension name and the Dimensio Axis 262647 - CADCollFindVectorPoint() incorrectly returning nothing 262663 - Many small problems in QuickStart construct Circle dialog (see picture) 262771 - Customer is not accepting FORM ONLY profile controlling size 262912 - Application is crashing during pp execution 262963 - MYCRONA: Focus during Calibration of Probe Offset on all Targets doesn't work 263383 - In Probe Utilities move speed and touch speed say mm/sec regardless of "Use Absolute Speeds" option under Setup" 263459 - Rotary Table simulation (offline) produces "Move commanded outside travel limits" error 263497 - FS#1866 pcdmis will crash when import the attached catia file 263540 - Wrong translation of SETUP in installation program 263546 - Word wrap on reports created in V37 263825 - Reference to surfaces for datum E doesn't import -> can't plan any of the FCF that references to datum E 263876 - Scanning Find noms operation failing. 263893 - Calculation of True Position involving Composite 263853 - 4.3mr1 shipped interface or latest will not home cmm. 264284 - Get Toggle type working 264311 - PCDMIS closed when I change the color from the CAD and open the View Setup. 264358 - Too much precision displayed on Solidworks DCI distance dimension 264488 - DF Measured results have changed between versions.... 264502 - On a HR template the CAD Object does not hide the Feature ID Labels even thoug they are hidden on th Graphic Window an also in the HR Editor 264516 - Autoexposure seems broken. 264526 - PC-DMIS should only show the list from the CATproduct and not also the list from each CATpart 264557 - When I try do dimension per unit flatness of this line I get an application error. 264683 - Profile and Flatness Dimensions 264685 - Cylinder wrong on import 264754 - If user clicks the Feature Location icon on the dimension toolbar It takes up to 30 seconds to open it 264786 - Rotary scan can not key in the polar angle correctly which is greater than 180 degree 264843 - Auto sphere creates an incorrect "auto move" path 264837 - Best-Fit to a single point not working correctly 264924 - Generic output data is incorrect 264963 - Probe tip variables not recognized in a loop 264968 - Different text file encoding when running a PP using PC-DMIS v 2009 or v4.3 264984 - PC-DMIS crashes importing scan commands 264986 - Angle dimensions are always positive 265036 - AnyOrder Execution on portable devices is broken 265046 - Temperature sensor tool changer Position Update timing on PMM and PARK/ENDPARK fix 265040 - The LED of the Tesa Star probe is not in the front of the probe 265051 - TP can't work correctly when use polar angle and radius 265117 - DMIS Import: strange tip angles being added to the program 265131 - Interpretation off Angles in degr Min sec is wrong in PPAP Report 265136 - Measured Circle hits get corrupt when F9'ing to edit the number of hits.... 265140 - LastProbeFile setting being incorrectly set for offline case when not really offline 265165 - DELTA Slant model is the old one 265167 - Dimension Flatness and Parallelism 265174 - Part program will not execute all the way through stops after the last measured feature. 265176 - Add DisableScanQueuing to Cummins 265190 - Error messages from the ZEISS controller 265260 - With the ShowCadGDT setting set to False I still see GDT symbols on the UG part model. 265262 - When I try to access help topics for "Assembly Support", I get a script error. 265273 - Impossible to open existing part program 265285 - Incorrect import of a STEP file. The CAD model is in Inches. 265306 - The attached models load fine in 4.3 MR1 using Alternate IGES but now fail to load correctly in 2009 MR1 using the standard translator.... 265349 - Pc-dmis crashes when printing the edit window in Chinese resource 265343 - Can Pcdmis support for flatness GD&T callout with MMC condition modifier? 265354 - Patch scan definition can't be managed 265355 - Thickness calculation is incorrect in scanning section 265372 - Flatness per unit 265383 - High point can't capture the new position after you click one time on the same surface 265439 - 3 dimensions get different results (.023mm) in 2009 with SP25 vs.TP200 probe 265449 - Application Error when I perform Inspection Planner after installation. 265472 - Find Noms doesn't always work correctly 265475 - The command Delete produce a duplicate sequence of feature labels in the dialog. 265476 - Create Offset Line. Theoretical gives correct solution. Measured is incorrect 265493 - Probe readout if using LiveReadout (Synchrotrack) is always in mm even if working in inches 265495 - The paper size of the object "The frame" can't be changed 265498 - FCF True Position Error: Repeated feature & possible probe comp error 265505 - Big problems with probes and their diameters 265518 - True position of a circle produces varying results dependant on the active workplane 265530 - High hitspeed bending probes - zeiss old scanhead 265556 - RMEAS broken... again? 265566 - CAD machine model needed for a Scirocco 13.20.10. There is only one model for a Scirocco CMM and it is about 1/3 smaller than the 13.20.10. 265587 - Probe is not correctly shown in grafics by clicking in Partprogramme between different probes angles. 265588 - Scale the drawing documentation is incorrect. 265593 - Compatibility of edge points between 3.25 MR3 and 2009 using 5 sample hits (Benteler Germany) 265611 - Mistakes in English resources on use of %s 265644 - FCF Labels from migrated programs are 'on' when program is opened in 2009MR1 265646 - Incorrect Toolchanger motion for SCP600 type 265659 - Translation for PowerLock is incorrect 265679 - Gauss filter and Outlier removal don't work in circle scans not located in the XY plane 265668 - Dimensions 3D and 2D Angle was positiv in older Versions in 2009 they are negative 265699 - Toolkit: Gauss filter only works in X-Y plane 265704 - MCR20 toolchanger calibration fails for Premium configuration 265730 - PC-DMIS doesn't find the correct tip for a given shankijk when it is a FIXED HEAD probe. 265783 - Crash when moving the mouse pointer over the LIV if no camera active and the toolbox is on the illum page 265789 - Dual camera system using wrong frame grabber input 265792 - Feature executing in the wrong place on special high magnification system 265794 - On high magnification systems with certain ring gauges the cross probe calibration fails 265798 - Resizing machine does not work 265817 - Positive Reporting is still not correctly looking at the plus and minus tolerance of location dimension 265887 - TESA STAR M roate to an strange angle during the taking hit manually 265942 - Analysis Window's labels are out of the part 265952 - Cannot change probe if TC oriented along Y axis (the same happend with PCDMIS2009) 265961 - Toolkit Extensions should not queue scans ffor the time being 266250 - MYCRONA: calibration data of stacked rotary tables stored in wrong folder 266432 - Graphical Analysis is not displaying correctly for FCF Runout dimensions. 266449 - Rotary table compensation for CNC implementationos is wrong if the table vector is not "pure". 266530 - Invalid error label is in the iterative alignment ------------------- Technical Preview 2 Updates (November 30, 2009) ------------------- 106103 - EN # 505877. Implement a feature extraction library able to work with all the non contact sensors supported by the company. Step 1: Integration of the Cognitens libraries. 106391 - Need ability to turn specific HASP option on/off through executable 106392 - HASP SRM 1 - Create base HTML templates set up login form so that people can log in and out 106393 - HASP SRM 2 Create way for users to update their account info (name email telephone location etc.) 106456 - Update ExtCmmData 106480 - PC-DMIS Icon Cleanup 106522 - ER# 505963 : TESA - Add support for new Visio Jogbox on the VISIO 300GL 106583 - Add 45 degree CNC probe model for Red Bull 106584 - Create Sheffield Apollo RS-220 machine model 106607 - DMIS: Bump m_dmis_version to 5.2 106680 - Add Generic XML Output/Input Function to PC-DMIS 106681 - Add XML .NET support into PC-DMIS 106685 - Make the logger diagnostics files to stay under the same folder 106704 - Add new dual arm machines to packing list 106706 - Need to be able to select Vision for the Basic and Premium configuration 106707 - Integration in PC-DMIS of the CMS toolkit V.2.1 for Ver.3 sensors. Step 1: create a patch in PC-DMIS for installing the previous CMS toolkit v.2.0 for compatibility with the pevious CMS sensors Ver. 1 and 2. 106721 - On CAD import support merge 106747 - Move schema def into implementation so schema bump doesn't require rebuilding so much 106793 - Fix packing list for changes that were transplanted where the associated fiels were not through QA 234275 - Offline: "move commanded outside travel limits" on the initial moves of the pp. 242145 - 2D angle dimensions to features between a line and a plane result is coming out different. 248442 - Why is the DIST2D calculation only reporting the distance in one axis? 255588 - Sometimes the machine will stop after the first DCC hit measurement and the operator has to press DONE twice on the jogbox to continue in DCC. 257115 - step import not working on a fresh program in 4.3 257553 - CRASH : delete dimensions pc-dmis crash 258464 - CAD imported with Step is unusable 261161 - SYSTEMS 4 UI : true position in between get incorrect result in Chinese resource 262773 - The comment command above feature MLBHV1245_UZAA is added twice whenever I run the optimize path operation 262970 - SYSTEMS 4 CONFIG : PC-DMIS Basic & Premium expose CAD functionality if the part program was created in a higher product level.... 263010 - Drop down list next to Set as Default icon in Reporting Toolbar does not function 263098 - Unable to select Auto Features on CAD model (imported as JT model) 263122 - Stupid merges needed for Mercurial 263440 - Feature Calculation Error the first time I've tested this circle 263669 - Point Info shows the values from the previous execution 263797 - The Close button in the CAD-History dialog is not anchored. 263896 - Load an IGS-File 264026 - Please review the default Increment2 values for Patch scan for the various CMS modes 264027 - Row Overlap does nothing on scans 264053 - Summary Mode and Edit Window are out of sync 264162 - FTA display is not working properly after PART/Machine relation is defined 264210 - 3D distance is initially wrong 264285 - ColorMapSwaps Surfaces 264442 - COPOPER IMPORT xyz file only imports file in metric units 264478 - LongLine filter: can't use the arrows controls are misplaced 264479 - Weighted Average filter: values misplaced in the controls 264530 - Ringband showing up for EdgePoint in Summary Mode 264547 - True postion header no longer word wraps it did just fine from 4.0 to 4.3 why was it stoped 264549 - The FCF Line profile of a prismatic (Circle) feature is defaulting to VECTOR fit. 264564 - Feature naming is wrong if you use Remove Last Feature 264601 - A probe 'reflectorless' is not created 264665 - Starting with cursor at ending of the program Portable Laser Execution isn't working right. 264672 - Scan label displayed in the wrong place on the CAD model 264679 - On TesaVisio 200 Zoom manual illumination is not refresh properly : changing illumination with step less than 0.5% is not sent to the machine controller. 264684 - /interface:TPS switch did not configure installation correctly 264688 - Legacy True Position dialog has some border overlap issues in English... 264689 - Part of the Location Advanced dialog is bleeding over into the Basic dialog... 264695 - Inconsistent confusing and unstructured command syntax for COMMENTS. 264700 - The GeoCOM error numbers need to be be presented as error strings 264757 - Plan dialog: the Cancel button doesn't correctly work. 264780 - OLH documentation can't pull out both English and Chinese 264785 - Calibration Math Error on A45 angles very high errors ( 2mm ) on A30 angles 264793 - Portable Laser Execution doesn't highlight points 264807 - Point comp. to reference feature does not work 264825 - If find noms from CAD is on the system takes not the vector from CAD but always a wrong one (e.g. 0 0 -1) 264826 - RingBand:inconsistent terminology 264856 - Install on TesaVisio 300 GL DCC : setting in registry isn't setting correctly 264857 - On TesaVisio 300 GL DCC speed setting and axis size are not set properly 264868 - Unable to run program with animation when enabling/disabling the loading virtural cmm machine 264880 - Hartzell part scaling error when importing a plan 264882 - Edit Comment dialog remains after location dimension dialog is closed 264884 - When renaming Plan 1 the name is converted to all capital letters 264885 - Comment command placed after location dimension instead of in front of location dimension command 264887 - Display on Report should be unchecked in the document comments 264889 - Problems with IP import comments 264891 - "GD&T symbols displayed inside the part unless ""Show lines over surfaces"" is checked" 264892 - VoidDetection.ipd should have End Offset set to 3 for Auto Cylinder 264897 - execute the 2D profile measurement with rough edges make pc-dmis crash 264898 - vision Stage calibration makes pc-dmis crash 264899 - update changed nominal values into dimensions make pc-dmis crash in Chinese 264926 - 'Towards' and 'Away' radio buttons on QS plane feature disappear after selecting the probe utilities dialog. 264927 - 'Away' should be the default choice in Quickstart on planes after installing PC-DMIS 264948 - Search ID box requires Tab key, not the Enter key to select 264941 - The COPY-PASTE command creates a wrong structure in the list of the elements. (Perimeter Points) 264947 - It misses the control of the duplication of the external and internal features to the Perimeter Points. 264948 - Search ID box requires Tab key not the Enter key to select 264949 - PC-DMIS ((XYZ) Screen Counters) are not functioning correctly and Flashing in the Graphics window. 264957 - Crash on File_Exit if the sensor has been used ( for example to test features ) 264958 - Warmup problems with the attached program 264960 - Crash trying to calibrate a newly created probe existing probes are ok 264961 - probe readout window in polar coo system shows wrong DPA and DPR values 264966 - Creating and selecting new a probe from QS does not enter a new load probe command in the Edit window 264969 - Probe head rotates testing an extracted AF online 264978 - Planner copying process fails to remove older versions from the FTP 264980 - Multi-Capture crash when measuring slots 264982 - The CMS 106Ac probe will not qualify. 264992 - In Cmm interface only TesaVisio 200 is display must be also TesaVisio 300GL 264995 - Nivel/Level TiltReadout has no more TitleBar and can not be moved around or resized! 264998 - No clue as to what to measure during portable laser alignment 265002 - COP not referenced by AF's (Not Portable Laser Execution) during execution don't pause and allow for scanning 265024 - Rotary table coordinate system is not handled in the right way - STOP RELEASE 265025 - Create FCF TP with polar coordinates in 4.3 - program loads in 2009 MR1 showing XYZ instead of PR PA 265041 - Pc-dmis crashes if you insert a nominal segment on a 2d profile and then save your PP. 265044 - When executing a measured feature the vectors get messed up 265063 - In some cases blank COP entered for portable laser AF's. 265109 - Auto sphere (and probably cone) behavior broken by recent changes to HIT_HELP.CPP for PR#264693 265111 - execution pauses when toolkit custom commands reference internal commands 265135 - part program created off line with solid works dci once opened on the cmm that does not have the dci 265147 - Checkbox on Asci import dialog saying update features which should needs to go away since it OVERWRITES measurements without warning 265157 - CAD File size increases everytime PP is executed 265159 - Need to Hide in/out on QS if measuring single point circle or two point slots. 265169 - Snap to grid snaps to the wrong axis 265211 - Edit window gets colored permanent when they view the path line. 265216 - Portable Laser execution is highlighting features which aren't marked for execution 265217 - 'Path lines from cursor' is not working correct in multiple arm part programs 265236 - Can't calibrate or get a live view of the laser stripe with my V4i 265237 - Remove RawDataPoints and Ouliers 265244 - Setting "ShowCADGDT" in the settings editor didn't work any longer" 265256 - Exit PC-DMIS with Laser view open crashes PC-DMIS 265261 - When executing a program on a Faro Platinum Arm the arm will stop taking hits. 265263 - Generic machine dialog failing when usermachine.dat has descriptions that use draw files 265294 - IDL file does not know about Perimeter Points 265300 - Crash on first pass of qualification run CMS 108 V2 and V3 265307 - PC-DMIS crashes when change manager starts 265308 - PC-DMIS needs to build insplan 265314 - Feature extraction crashes 265319 - Installation for CMS Installs the wrong old files CMSensor2008.dll and NCSensorModel2008.dll 265325 - Two reference features highlighted in the edit window 265333 - Sensor Hardware Error dropping the contact probe during a change to CMS 265353 - All levels are not available 265368 - Path Lines for Audi Extended Edge Point are incorrect 265388 - They can't copy and paste object from one report tempate to another 265401 - Polar radius deviation tolerance band drawn incorrectly. 265403 - change to RDS_GetErrorMessage in Romer interface as recommended by Brian Frolich 265404 - Progress percent shows when loading .draw files using CADCollCreateFromArchive() 265435 - Leap Flog inverts visual sense of the probe. 265442 - Can't register CMSensor.dll 265459 - The note in the FCF is unintentionally modified after the command F9. 265461 - Change title bar from "2009" to "2010 265512 - Memory leak from CAD levels dialog ------------------- Technical Preview 1 Updates (November 15, 2009) ------------------- 106552 - Allow a Move command that moves in 1 or 2 axes only (instead of all three) 106545 - NIST App Enhancements 106544 - Do MultiGage style 24x24 icons for the Measured features Reflex Page 106543 - Do MultiGage style 24x24 icons for the Constructed features Reflex Page 106542 - Do MultiGage style 24x24 icons for the first Vision Live View Toolbar 106524 - Add alignment controls to the constructed features on the Vision Gauge window 106515 - Add hole pattern to the Sheffield Apollo RS-50 table model 106514 - Implement a feature extraction library able to work with all the non contact sensors supported by the company. Add cloud needs to pass the feature type. 106509 - Add the ability to enter move points in polar coordinates 106507 - UV and grid scan types only show 2 decimals for xyz in path definition page. 106499 - Add a "Help" button to the Settings Editor to make it obvious that there's OLH available... 106495 - Handle warnings as warnings and not errors 106488 - Add constructed features to the Reflex Vision Gauge window 106482 - Integrate of the new CMS Ver. 3 Cad model and geometry into PC-DMIS 106470 - Add feature set handling to task #106251 106457 - Make doc & MOD schema doubles 106450 - WaitOptimization for tool changer on special option 106442 - Change all instances of power lock to the Leica branded version - PowerLock 106429 - Add a 3D construction to hole type features 106383 - Reporting ZEISS controller error messages to PCDMIS 106348 - Fix [Config] option output into the debug file 106249 - Enhance visual aspectsof the custom report graphical analysis lines 106235 - Add the ability to save transforms to be used for later transform operations 106086 - Develop 'probes' to represent different measurement modes of the Total Station 105935 - Add Zeiss Carat machine to the build 105876 - Add Reconnect / Disconnect automation items to support Leitz machine firmware. 265031 - Cannot create freeform scans on most CAD surfaces 264955 - Zeiss new interface doesn't compile under VC 6 264906 - ManualCMM - wrong read-outs after alignment 264863 - Summary Mode doesn't work for the Toolkit 264827 - Can't measure or extract a Round Slot using a negative Overscan: I always get "Invalid Data" 264791 - "Feature Calculation Error" when executing program on some features but test works fine on same features 264740 - Need ability to add move points to FreeformPlane 264735 - When I do a Qual Check on a SP25 The value of PRBDRV changes. 264693 - AutoCylinder Stud probing path has changed from version 4.1 to 2009 MR1... 264690 - AutoCreate dimensions flag is not staying set... 264661 - Push Probe Version resource changes related to file format conversion 264587 - Volcomp file load leaks a stream handle on exit 264573 - Can't construct a plane using outlier removal and Gauss filter: it crashes 264567 - Reflex Vision - Icon needed not button 264531 - EdgePoint crashes 264476 - Rotary Scan 264472 - I can type negative values for Spacer and Indent in the AF dialog, even if they're invalid 264458 - Opening a program twice causes an application error. 264448 - When selecting cad to create AF's the pathlines are being re-drawn multiple times. 264441 - PDF output not working in Vista x64...or Windows 7 264440 - Some tooltips are wrong. 264436 - Sensor not initialized after probe change from CMS30 to CMS 264312 - ANSI_Y14_5_Dimens_AngleCoaxSymm automated test is reporting a failure 264284 - Get Toggle type working 264283 - Get IDimension working 264282 - RMEAS "default" is broken. Causes a crash. 264245 - Serializing back to previous versions, and then reopening with PC-DMIS 2009, the versions from V3.2 to V3.7 are crashing PC-DMIS 2009. 264240 - PowerUser installation/usage issues at Stadler rail 264224 - Pressing F1 on REPORT/TEMPLATE or its menu item goes to intro help topic 264204 - Siemens NC Read Cnc Var sometimes hangs 264165 - Auto Round Slot measurements with sheetmetal probe are not solving correctly 264154 - "Working with Contact Find Hole Properties" doesn't not exist in 2009 English OLH 264132 - When opening a V4.2 (or V4.3) part program w/ CAD and COPS takes nearly 3 minutes on the same laptop the program used to take a few seconds. 263991 - If they set the reference to a CAD file that has been created previously during a mirror operation, then the original not mirrored CAD file opens. 263984 - Snap = YES will not stay when using Point Only Mode and Find Noms 263983 - PC-DMIS is crashing when mirroring a part program 263981 - Stop prog execution using automation 263925 - When using the iterationalignment wizard, at the 3rd step , the features in the feature list always miss one . 263917 - PC-DMIS crashes, application error, when selecting TEXTANDCAD template in report window 263902 - Can wipe out custom reports without knowing it 263884 - MazakIntegrex creates header line in EIA files that is unreadable by Matrix controls 263770 - When using TEST button with Autofeature Edge Point, you don't see the final points in green like other laser autofeatures. 263706 - Help file for Laser: No explanation of the Auto Clipping function 263693 - Point Info returns a wrong value 263692 - Select Point Info Dialog did not show the FCF 263609 - Best Fit Alignments not updating when using 2D Profile 263474 - The wrist of Arm1 unawares rotates of an angle of the wrist of Arm2 263441 - Crash trying to expand commands in the EW while the AF dialog is open after a feature has been tested 263321 - Can't use Mark Used from probe utilities/Measure dialog whe modifying saved parameter set. 263230 - Path lines of Auto Feature are not correct 263127 - If Abort is pressed in Metrosoft, the server often hangs up. 262579 - Update Nominal feature option should not update feature nominal in some cases 262509 - CAD window can't display this part model stably 261642 - Cannot output Flatness of any constructed set of (2) Measured Planes... 261408 - Absolute speeds between multiple arms 261407 - Scan Speed not sent to ARM2 261406 - Point density not sent to ARM 2 261176 - Value instead of Variables showing in AutoFeature Start/End Angle fields when opening a prior version (e.g. V4.1) PC-DMIS program that uses them - PROGRAM MIGRATION ISSUE 258860 - In French language Help is old 42 version and it is not linked with the active window 258352 - Patch Scan with WLS, last scan always goes to D point 257908 - Problem handling comm port related communications for ACR1 and probably Tesastar-R when used on slave arm of dual arm system 257828 - Incorrect Probe Animation with rotary tables 257257 - The message asking "OK to empty this pointcloud?" should include the Cop object ID 255356 - Settings Editor doesn't start up ****************************************************************************************************** ******************************************************************************************************