Wilcox Associates, Inc. PC-DMIS® Version 3.7 Enterprise Metrology Solutions Installation Notes: 1) General System Requirements 2) Information about this release 3) Beta Test Site Agreement Form 4) New Product Information 5) Release Notes ****************************************************************************************************** ****************************************************************************************************** 1) General System Requirements Minimum Requirements: - PC-DMIS® 3.7 operates on computer workstations using the WindowsNT® 4.0, Windows2000®, or WindowsXP® operating system. No other operating systems are supported. - 300 MHz or higher Intel processor. - 128MB of RAM plus any requirements for the operating system requirements. (192 MB RAM if you use Windows2000® or XP®, 160MB RAM if you use WindowsNT® 4.0.) - 500MB of free hard drive space minimum for the application. - SVGA graphics card capable of open GL shading and with at least 16 MB of on board memory. We cannot specify an exact graphics card since every user has varying needs. - SVGA capable monitor. - CD-ROM drive. Recommended Minimums: - Windows2000® or WindowsXP® Operating System. - 1 Ghz or higher Intel processor for improved performance. - 256MB of RAM or higher. More RAM may be required if working with large CAD models. You should have RAM equal to 8 times the size of the largest CAD file you will use. (For example, if you use an IGES model of 250 MB, then 2 GB RAM is recommended.) - 500MB of free hard drive space plus allocated Virtual Memory of 8 times the largest CAD file used. - SVGA graphics card that supports OpenGL shading and that has WHQL certified drivers. On board video card memory should be based on the size of CAD file being used. - For small CAD files (less than 50 MB), 16 MB video memory. - For medium CAD files (50-100 MB), 32MB video memory. - For large CAD files (> 100 MB), 64MB video memory. WHQL (Microsoft Windows Hardware Quality Labs) video drivers can be downloaded automatically when using the Windows Update software. - SVGA capable monitor. - CD-ROM drive. - NOTE: Depending on your specific needs, the recommended system specifications for this version of PC-DMIS may be much higher. Be sure to consult with your PC-DMIS distributor to find out the type of computer system you will need in order to run this software at its optimum capability. ****************************************************************************************************** ****************************************************************************************************** 2) Information about this release. We at Wilcox Associates are proud to bring you this new version of PC-DMIS® 3.7. This Enterprise Metrology Solutions platform brings together new aspects of PC-DMIS® for the development of a complete manufacturing process control solution. Available in this release are variations of PC-DMIS® designed to assist with every aspect of the fabrication and quality control process. The newly created packages include PC-DMIS® Vision, PC-DMIS® NC, as well as the established PC-DMIS® Pro, PC-DMIS® CAD, and PC-DMIS® CAD++ platforms. Also included with this release is PC-DMIS® ONE, a simplified shop-floor DCC inspection package developed in cooperation with Brown & Sharpe. The testing of this version has been significant. We’d like to take a moment to discuss this process and also make you aware of the various components of testing. Testing is comprised of two parts. These can be described as functional testing and integration testing. The vast majority of testing effort goes on in the functional area. This is the testing that determines that specific functions that are core to the software, regardless of what type of machine is used, are working correctly. The integration testing is essentially a testing of the interface with a particular type of machine. In the ideal scenario, WAI would have access to at least one of every piece of hardware that is operating in the field running PC-DMIS®. However, in practical terms, this is impossible. This integration test plan is then performed on as many types of machines as we have available. Unfortunately, there will inevitably be machines to which we do not have access and that cannot be fully tested in this manner. To this end we have made an effort at closing this gap by partnering with our customers through the Beta Test Program. On the following pages you will find an application for this program. We urge you to consider signing up for the program as it provides the mutual benefit of helping us create the best product possible for you, our customer. Should you experience problems with your system after installation of PC-DMIS® 3.6, it could possibly be an integration problem. If it is a problem of this nature, it will probably be evident immediately upon first use of the possibly untested configuration. Should such a problem materialize, you will be given the highest priority for correcting these problems. Please call Tech Support immediately to report any integration problems. For existing users of PC-DMIS who currently have earlier versions of PC-DMIS® installed, it is advised that PC-DMIS 3.6® be installed into a new directory. In this way, you can be assured of continuous use of the existing version should problems arise with this newer version. ****************************************************************************************************** ****************************************************************************************************** 3) Beta Test Site Agreement Form As part of our ongoing efforts to improve the quality and ease of use of PC-DMIS®, we would like to actively involve our key customers in the development cycle. There are several advantages of being involved in the PC-DMIS® Beta Test Site Program. You will: • Preview cutting-edge PC-DMIS software enhancements • Provide direct input into the development of PC-DMIS • Receive a 25% discount on one PC-DMIS Software Maintenance Agreement (SMA)* To qualify for this program, you must meet and agree to the following requirements: • Have a machine/interface type required by WAI/Brown & Sharpe Manufacturing Company for testing purposes • Be willing and able to download and run Beta versions of PC-DMIS® • Be willing and able to perform specific tests as required by WAI/ Brown & Sharpe Manufacturing Company when necessary. These tests must be performed as outlined and within a mutually agreed upon, reasonable time frame. ________________________________________ _________________________________________ Company Name Contact Name ________________________________________ _________________________________________ Address1 Address2 ________________________________________ _________________________________________ City, State, Zip Phone ________________________________________ _________________________________________ E-mail Address Fax SMA Expiration ___________________ CMM Type ____________________________________________ Manual/DCC __________________________________________ CMM Serial # ________________________________________ Controller Type _____________________________________ Portlock # __________________________________________ Interface Type ______________________________________ Operating System ____________________________________ I have read the PC-DMIS Beta Test Site Program Agreement and agree to all terms stipulated: ________________________________________ _________________________________________ Company Name WAI / Brown & Sharpe Mfg. Company ________________________________________ _________________________________________ Company Representative Name Representative Name _________________ ___________________ Date Date *If any of the terms of this agreement are not met by either party, this agreement will become null and void and any discounts will be immediately revoked by WAI/Brown & Sharpe Manufacturing Company. All technical correspondence should be directed to Tim Wernicke of WAI via E-mail or telephone (262) 338-0887 Please mail, e-mail or Fax this completed form to: Tim Wernicke Wilcox Associates, Inc. 932 Tower Lane West Bend, WI 53090 Phone (262)338-0887 Fax (262)338-8006 e-mail twernicke@wilcoxassoc.com ****************************************************************************************************** ****************************************************************************************************** 4) New Product Information (Note: EMS products remain in Early Adopter stage until formal release of each is announced.) PC-DMIS® Version 3.7 Enterprise Metrology Solutions possible options: PC-DMIS® Vision - Designed specifically for non-contact measuring applications. This product offering is functional on the RAM Onyx, Datastar, TESA VISIO, and OMIS/OMIS II optical CMMS. It is expected that the available options will change rapidly with this product as new interfaces are developed. PC-DMIS® NC - A true measuring package available for use on a computer controlled machining center for initial layout and setup inspections, first piece inspection, and even final inspection of machined parts. PC-DMIS® INSPECTION PLANNER - Reduce part programming significantly using automatic programming tools from the IP Measure Module. Add an Inspection Plan from the CAD embedded IP Planner Module to accelerate time savings even further. PC-DMIS® GEAR - A simplified user interface designed for basic gear measurement. This includes the measurement of internal and external spur gears and helical gears. PC-DMIS® STI+ - This is a migrated version of the original Sheffield STI. It provides for an easy to use utility for the creation of a customized front end for program execution, as well as some nifty tools for creating custom 'slideshows' or graphical reports. ---------------------------------------Major Enhancements--------------------------------------------- - A Lighting & Material Dialog (L&M), for textures, transparencies, lighting, and clipping planes was added. - A Preview Image of last Graphics Display Window was added - The user can now hide and show various graphics categories such as Models, Probes, Machine, Tool Changers, and Fixtures. - A Rotation Options Dialog has been added as a result of work that was done on the SpaceBall project. It allows the user to set various options to improve redraw performance when doing 2D or 3D rotations using the mouse. Settings are not used when interacting with the 3D Rotate Dialog. - SpaceBall mice are now supported. - Perceptron Laser scanning is now supported in an early adopter version. - PC-DMIS Gear is now an viable option. - Mouse over highlighting, graphical texturing, and graphical lighting enhancements have been implemented in the graphics window. Mouse Over Highlighting (MOHL) is Activated by the SHIFT key while the mouse is moving. - Preview and Edit capabilities for Auto Features have been implemented. - Custom Colorization by Command Type allows the user to set color modes (Marked, Unmarked, Step Mode, Error) by command type or command group (Alignments, Features, Dimension, Comments, etc.) and also re-organizes the Edit Window Color dialog. - A new registry setting controls the under buffer size when deleting commands. - The Equate Alignment dialog was clarified by adding “Old” and “New” to the combo box captions. - Machine coordinates can now be shown in the Probe Readouts window. - Multiple columns can be displayed in the Probe Readouts window for showing information about more than 1 arm at once. - A comment with the command mode text of commands that don’t exist in previous versions was added for when saving to a previous version. - A Data Field Edit Wizard for editing common data fields (SHOW_HITS from Yes to No) all at once was implemented. - Separate entries in the pop-up menu for showing or hiding dimensions and point info boxes has been added instead of controlling all of them through the Feature ID's when in text box mode. - Iterative Alignments now have the ability to specify a maximum number of iterations to perform in cases where alignments do not converge. - The Form Feed Command implementation has been improved. - Column Tracking was added to the edit window for when cursoring up or down so that the user doesn’t always end up at lowest column. - An ability to Jump to a Reference ID and Back was added through a the right-click menu in the edit window. - The Right and Left cursor arrows on the keyboard can now be used for expanding or collapsing items in the Summary Mode tree view. - Edit boxes in Summary Mode no longer limit the number of characters a user can type when editing a field. - A “Cancel” button was added to the “Ok to rotate Dialog” during program execution. - An Offline Execute mode was added that doesn’t overwrite previously measured values. - A Skip Button was added to the Execution Mode Options Dialog. - A warning was added to indicate that a user must exit PC-DMIS for changes to take effect when making changes in the Multiple Arm Setup dialog. - The Calibrate button in the Multiple Arm Calibration dialog is now disabled until all needed parameters for calibration have been selected. - The default button for jogbox Done button operation now connects to the to the Read Position button in the Multiple Arm Calibration dialog. - Circle construction at cone height no longer requires the top of cone to be oriented in the ZPLUS direction. - Auto Feature paths can now be modified in the Graphics Display Window. A graphical representation of hits and path lines can be clicked and dragged for the needed change. The number of hits as well as other path parameters can be modified in this manner. - Void Detection – Methods have been added to accurately detect voids in a CAD surface and then position the dcc hits accordingly. For example, a plane may have a holes in it, and the hits will not be taken in those areas. – PC-DMIS has the ability to calibrate just a few tip angles on a probe head and have all 720 tip angles calibrated. - An accelerated method has been added to allow for changing of Global variables within PC-DMIS. Quick changing of values can be facilited through user created Automation scripts. - Auto Create Dimensions options uses Auto Form. For planes it creates an Auto Flatness, with lines it creates Auto Straightness, with circles it creates Auto Roundness, etc. - Improved Wheel Mouse Functionality: Scrolling the wheel back or forth makes use the Zoom in/Zoom out function. Depressing and holding the wheel down activates the 3D dynamic rotate function. - Interface support added for the Zeiss VAST tool changer ****************************************************************************************************** ****************************************************************************************************** 5) Release Notes PC-DMIS® Version 3.7 is a significant development release of the software. Initial Release Date: December 10, 2004. **** Prior to the release of Version 3.7, Version 3.6 was last official release of PC-DMIS® by Wilcox Associates, Inc. and the Brown & Sharpe Metrology Group of Hexagon Metrology. ----------------------------- ENHANCEMENTS AND NEW FEATURES IN VERSION 3.7 --------------------------- Miscellaneous enhancements: 226049 Clipping planes were added to see sections of a part. 226784 PC-DMIS would hang when changing CONSTR/CONE to CONSTR/CYLINDER. 226684 Stats count was not a property of the PartProgram object as it should have been. 226679 When creating a part program via automation, the title bars for the edit window and the graphics display window were incorrect. 226687 The PartName was not being set when creating a new part program via automation. 226677 Parts.Add did not put in the SetActiveTip command. 226675 CurrentUserDirectory returned . 226637 UV scan created hits in midair and inside part in the graphics window. 226491 Cmd.count was returning the wrong value when using loops. 226288 Marked Sets were getting destroyed during execution. 226261 Changing alignment offsets multiple times was not always automatically updating the Edit Window features. 225927 New Leitz PMM controllers were blocking some PC-DMIS communications. 225906 Quick Fix fixtures have been added as modelling components. 225770 Crashes when I try to create a filter set from a circle. 225782 'A unknown attempt was made to pass …' message when the open their existing pp's. 225775 If the number of the comments overpass the number of visible lines in the Readout a scroll down is needed each time a new comment goes in the readout. 225393 Start points are not exactly at the feature thatis just been meaured. 224930 basic1.h use 224916 autofeature dlg synchronization issues with multiple loaded programs: file->exit enable? 223867 DCI flip based on in/out of material 223413 Why the change of the measure (by F9 command) doesn't produce the message of updating? 225601 Multiple Arm Calibration is broken (from Operation | Multiple Arm Calibration) 225553 Speed up the display of point deviations dot/needle/text color maps 225511 Add automation access to MAN-DCC and DCC-DCC, which are used in wrist mapping. 225329 Is there a way in automation to loop through the T deviation in a scan or profile dimension? 223686 Enhance Qualification Check Results to display at least six decimal places 221666 Please remove "Calibrate button" from operator mode "marled sets" layout. With Krypton it has no function 220204 CADObjectBoundaryDrop returns the tangent vector but not the edge normal vector. 219972 It is now possible to interrupt the search function on the SMX tracker. 219441 It is now possible to left-click and hide either the feature ID or DimInfo ID from the graphics window. 219412 PROF16 is OUT of Tolerance after a DMIS import - without having been executed? 218562 A new graphics toolbar has been added. 217015 Add a default label shadow setting 214824 A symbol to indicate in the Dimension Info dialog if a DimInfo or a Label was already created was added. 214270 A master defined path scan option was added. 213935 If a basic scan is created without measure checked, hits will be generated. 213438 Hits for basic scans are now generated automatically. 208140, 223091 Spaceball and SpaceMouse support were added. ------------------------------------------------------------------------------------------------------ Known corrections and improvements from Version 3.5 MR 2 and Version 3.6 that have been resolved: 226845 Quick start circles measured in the wrong workplane resulting with incorrect vectors. 226659 Unchecking the Probe Position option in the Readouts Setup Dialog caused an application error. 226502 Auto circle sample hits were sometimes being taken in voids. 226485 The settings editor forced administrator privledges even when the permission on the keys allowed that specific account to change the keys. 226409 Executing a scan after selecting To Points in F9 edit mode caused application errors. 226387 When clicking generate or filling the THEO list from the spline option the drawing of the points was slow. 226381 Hits were not equally spaced around a circle due to void detection. 226341 Cancelled scan execution was leaving the red interrupt arrow on the FORMAT command. 226366 Scans generated and executed offline were having their nominals corrupted during online execution. 226356 Opening some v3.5 programs in v3.6 could cause serialization errors. 226352 Deleting CAD surfaces from models was taking too long. 226301 Reading in a Catia 5 CATproduct file was causing assertion errors. 226273 V3.6 was much slower at importing UniGraphics files than v3.5. 226268 Negative form values were being output to Datapage. 226243 Best fit alignment error messages weren't displaying properly. 226242 Deleting a CAD surface that was underneath a previously deleted surface caused and application error. 226217 Some very large part programs could not be opened. 226211 Deleting a block of scans was causing application errors. 226188 Features could not be deleted from a Catia V5 inspection plan. 226179 Multiple rotations of the probe head were causing errors with a Sheffield controller. 226162 The readouts window would could show an incorrect number of arms on a multi-arm system. 226154 Clearance planes were not working when used inside of UV scans. 226152 When the print button was pressed with a scan dialog window open, PC-DMIS closed the dialog window. 226125 "CmmAccuracy" was missing from the Leitz section of the registry. 226108 Status window messages were updating to quickly when a dimension followed a point feature. 226102 The Print Report index was being set to 0 after import from Tutor. 226101 SP25 calibration was not working if the axis assignments were not normal. 226099 Manual spheres were not translating correctly when imported from Tutor. 226095 The correct auto features were not displaying on initial program creation depending on portlock configuration. 226091 Tesselation was not working well with some IGES and STEP files. 226087 When using the ToPoints button of a UV scan, only the first point got a label. 226084 Issues with skipping commands from the Remote Panel were improved. 226069 Executing some patch scans was causing application errors. 226068 A master scan would not find nominals consistanly when not using Cad. 226063 The functionality of the Draw Surfaces button was improved. 226060 Emergency errors could happen during wrist rotation 226059 Start pointers for Arm2 were sometimes pointing to Arm1 commands after a cancelled partial execution. 226051 Importing tutor programs to PC-DMIS was not always keeping the correct projection plane. 226022 Features were not displaying in the same color as their T axis deviations. 226014 Uppercase letters were not handled well in basic script format strings for time and date. 225992 The dragging of an element changed the ID sequence or it produced an Application Error. 225987 Toop tip text was missing from some buttons in the toolbars. 225947 Probe calibrations were not working well on some LK machines. 225935 Drawing points in the graphics window was slow compared to v3.5. 225932 BFRE planes and lines could not be saved to previous versions. 225931 When pressing F9 to edit and Auto Circle, it changed the Angle Vector back to the default for that workplane. 225930 TRACE commands were flagged as MASTER and SLAVE. 225920 An auto move on a second sequential auto sphere was not being executed. 225912 An imported Chorus program with branching was having the wrong alignment recalled. 225908 Extremely large part programs had memory allocation problems. 225905 The symbol of the dimension profile with form and position with both MIN and MAX positive was wrong. 225900 Menu options were not always remaining grey until a CMM finished initializing. 225899 The DMIS OUTPUT/R(day) statement wasn't imported but was commented during import. 225896 The cursor was moving to the Start Point after a cancelled execution. 225888 Would not find nominals when scanning over multiple surfaces using perimeter scan. 225879 Editing an Edge Point to have an actual thickness not equal to 0 would change the target value. 225861 After Best fit alignment, the correct profile couldn't be evaluated. 225854 Auto Feature with Actual Thickness not equal to 0 would not be measured with an NC-100. 225847 Application errors happened when using combinations of the Preview Window, Quick Start feature and auto feature. 225841 Option Dimension Text without Dimension Options was formatting incorrectly. 225838 DCC mode aimed to the next hit after each beam re-capture and did not allow measurement on the Leica interface. 225837 Application errors happened at end of execution when 'Press End Key' was disabled on the Leica interace. 225830 A Generic Feature Actual X2 line would be missing in Summary Mode. 225814 Importing an IP file returned a Runtime error on line: 561 - Overflow error... 225810 Several errors returned when selecting the external sphere in the hexagon_block.sldprt. 225785 Some ProE surface files could not be imported. 225781 'Unknown Probe for Auto/Sphere' message on Arm2 after an Auto/Calibrate Multiple Arm Command was executed. 225775 When the number of the comments surpassed the number of visible lines in the Readout, a scroll down was added for each time a new comment goes in the readout. 225774 Wrong arm assignment happened when using the distance relation from Quick-Start. 225770 Application errors happened when constructing a filter set from a circle. 225757 IP files could not be parsed. 225755 The Readout Window wouldn't update if there was no active probe or tip. 225754 Importing CAD with an alternate coordinate system imported in the incorrect location. 225751 TEXT/OUTFIL ''Has double quotes'' - This ded not DMIS conform. 225749 Application Error happened when pressing ACCEPT button in PREVIEW WINDOW. 225748 Erred management of the sequence of the label LOCATION when inserting dimensions from the Quick Start menu. 225746 DMIS 'OUTPUT/' commandd were commented out in the PC-DMIS part programs. 225745 The vector of intersected lines was changing during the part program execution. 225739 The gbarstate.dat file kept growing and slowing down program execution. 225734 A VB script that called printing would cause an application 225731 Dimensions formatted with Min/Max seemed to get corrupt in the report in Print preview. 225729 Label field was emptied when switching from RoundSlot to SquareSlot in the feature dialog in learn mode. 225727 There is a different behavior changing the sequence of opening Quick Start Construction window and the Preview window. 225726 The Nominals Changed with closing and opening of the part program 225720 NCSensor code related crash (access violation) when trying to execute non-NCSENSOR setup. 225718 The Readouts Window left a ghost on screen after execution was cancelled. 225710 Unhandled exceptions when opening a dual arm part program. 225694 Outlier removal for the constructed filter was slightly wrong. 225693 Opening the quick start point construction and having preview window open, when, after input feature selection, the Accept button is pressed on preview window an application error occurs. 225686 PC-DMIS was crashing when deleting certain blocks of commands. 225685 Planes with illegal DMIS parameters were generating ambiguous error messages on import. 225684 It was not possible to merge imported CAD files. 225683 Customized toolbars changed if the language was changed. 225679 Application Error during the selction of the 2nd element in the construction list. 225672 CATIA 5 DCT now supports up to R13 files. 225670 DMIS import fails (PC-DMIS dies) during 2nd pass after 12-15 messages "2D distance requires 2 or more features" 225666 Bad Angle points were being created from wireframe selections. 225665 Clicking FIND in the Angle Point dialog produced bad surface 2 vectors. 225636 Learned Notch opened in the wrong direction - not controlled by 'outside' click. 225634 When creating a custom toolbar and docking it on the menu bar, custom icons could change their icons. 225627 Probe crashed into the sphere between scans 3 and 4 with a beta build during ISO 10360-4 scanning. 225617 The circle target hits in the graphics window couldn't be moved. 225613 SolidWorks Inspection Planner exited when clicking on the Delete menu item without an inspection plan. 225605 SolidWorks died after opening a file which had a programmed inspection plan. 225604 Auto Planes generated by inspection planner were not representative of actual planes. 225601 Milti-arm calibration was not always working. 225599 PC-DMIS did not indicate a problem if Find Nominals on Priority Surfaces was accidentally checked. 225587 The Icons were not visible on the Alignment QuickStart toolbar. 225585 The wrong dimensions colors were shown for the amount of deviation found in a feature. 225583 gbars were not coming over properly from 3.5 to 3.6. 225582 Can't reduce Initial/Perm values by changing the Initial value. 225578 Part of the fixture does not show up in PC-DMIS, but did in UG. 225572 Point info boxes contained the icon after the second measurement. 225559 Online measured feature would have the wrong probe compensation if an offline program was open during execution with a different probe file. 225548 Some shading problems were seen in the graphics window. 225544 Importing a CATIA 5 R12 model caused application errors. 225541 MOVE/ALL commands assigned to arm2 cause a considerable delay of arm2 respect to arm1 during execution of dual arm part program. 225532 The iterative alignment target radius was not being imported properly from DMIS. 225525 Auto insert moves did not work when auto move was turned on in the features. 225524 Auto insert moves and program optimize has problems when the features are not actually modeled in the part. 225520 The button 'Standard setzen' in the 'Setup-Options' dialog was too small. 225516 Graphics Font ID labels didn't refresh with point size changes. 225515 Hyper CAD object "creeps" if activated and the scroll bars are used. 225493 SolidWorks DCI gave "type mismatch" when trying to open some models. 225486 Auto Circle arc's Angle Vector was not in part coordinates. 225469 Auto features were disappearing from the menus. 225453 PC-DMIS didn't load some SolidWorks DCI sheet body files. 225449 Negative infinite wrist rotation angles were sometimes being sent to Leitz controllers. 225442 The Chorus DMIS CALIB command was not importing properly. 225440 The ReadPos button now greys when the Move Increment option is checked in the Auto Move Point dialog. 225439 The Chorus GOTO/INCR CALIB command was not importing properly. 225437 Edit Preferences, Fixturing caused immediate PCDLRN.exe crash on Japanese OS. 225433 Programs saved to a previous version could not be re-opened. 225431 Inside a subroutine, the change active tip didn't work if the probe name is supplied in a variable. 225426 Attempted overstrike with alignment label highlighted addED characters to end of previous line. 225425 TextBox mode was broken. 225421 Loading a machine was unshading the CAD model. 225416 Memory leaks were repaired in the machine interfaces. 225408 Material thickness was applied wrong when switching types with a thickness value. 225397 Incorect indentation for constructed plane in Edit Window. 225393 Start points were not exactly at the feature that had just been meaured. 225391 The Catia V5 DCT now supports R13 files. 225383 The value of A and B angles didn't always get updated properly. 225376 The status bar is flickering all the time on an Online machine. 225373 Could not construct a BFRECOMP circle from a BasicScan/Circle using OFFLINE. 225359 No FILNAM statement was present in DMIS output file. 225358 .SAT Files imported with the wrong scale. 225357 Several DMIS syntax export problems and a serialization problem were fixed. 225356 Problems were encountered during basic circle scan creation. 225354 The angles A and B of PH10 don't appear in the status BAR. 225350 Slot true position showing the WF and LF didn't report deviation bars in the full report. 225332 Probe head rotations would not always happen on a Mora controller. 225331 Hyper-report last page was displaying oddly. 225321 Customized Toolbar did not retain correct icon image. 225320 Various menu items were missing icons. 225305 Circular motion was added to the Sheffield interface. 225303 The actual value of true position was not exporting to a DMIS file. 225294 True position dimensions were not updating properly. 225277 Application Error using Quick Start and Edit Window. 225266 Imported DMIS diameters were not in the dimensions, even though the dimensions were created in PC-DMIS. 225256 The registry key ARM2CompMode in DEA interface section existed twice. 225215 Init and Perm boxes in Autofeatures are now editable combo boxes. 225214 Auto Features with ReadPos capability would have their XYZ change when switching between Polar and Cartesian. 225202 Tutor strings containing the char " ("") were not being translated with \". 225201 Populating a constructed circle feature with input features using TutorElement ID I get an error message if ID is not defined yet and resulting instruction is incomplete. 225200 The Edit-ID window selected the label of the preceding feature. 225173 Application errors happened when trying to create edge points and other auto features with CatiaV5 files. 225164 Scans programmed in prior versions didn't use clearplanes and causing crashes. 225163 Inserting external alignments at the top of dual-arm program corrupted arm-2 alignments. 225153 Progress bars and status bars now appear at the same location. 225150 Arm2 measured values could be incorrect after an offline execution. 225149 Scans with angle points were not returning the correct vectors. 225133 GOTO statements could point to nothing if the referenced label was cut and then pasted. 225126 Editing ASSIGN/ commands in DMIS mode corrupted the expression. 225118 Couldn't ASSIGN featurename.I or .J, or.K, or .TI, .TJ, or .TK. 225116 RMEAS was not working correctly when used with READPOS. 225107 Collision detection tolerances were no longer taken into account. 225104 CAD views changed during IP import - shaded CAD data got unshaded each time. 225098 Execute Feature was overwriting the Execution Mode layout with the current Learn Mode window layout. 225081 Option toolchanger (MCR20) was not usable on the Metrocom interface. 225083 The Sheffield interface was not checking for the RCU version and sometimes this caused a 022 error. 225075 When using ISO TOLS with multiple features, PC-DMIS assigned tolerances based on the first feature. 225065 Pressing the Finish button too soon while creating a Quick Start Measure feature would cause an application error. 225057 Input of angle nominal and tolerance values were in Deg/Min/Sec format. 225044 Deleting not successive features could cause the edit window to lose track of cursor position. 225042 Double-clicking on Dim. Infos. within a report caused them to disappear. 225031 The dimension for the distances in PC-DMIS was different to the label in the AUDIMESS DMI file. 225013 If excution was cancelled while generating a scan, the cursor would go to the start of the edit window. 224986 Feature hits taken with the Leica interface were not being recognized. 224971 Incorrect Move for AutoSphere when AutoMove=Both and INIT and PERM=1. 224916 Autofeature dialog synchronization problems happened when multiple programs were loaded. 224848 Imported DMIS constructions didn't always include their feature points. 224835 Catia model import was hanging. 224772 Dim info boxes would only display default axes for particular feature. 224768 FEAT/POINT Polar can't hold a value when you hit F9 if you aren't in Z+,,,,X+ 224758 The Font toolbar was missing from the Hyper-view editor. 224747 Y Values returned in this DES file are 2MM different than they were in 3.5. 224746 DES file does not import all data. 224714 The Last Execution Report Mode window wasn't refreshing with the proper data following execution. 224704 Various problems with Auto Lines were corrected. 224684 Auto Vector Points had a CAD selection problem in polar coordinates. 224679 When using Quick Start to measure a circle, changing the feature name in the window did not save to code. 224667 Import of the Chorus DMIS SNSLCT/SA(CHIEF1),FEAT statement did not work. 224635 Import of a Chorus DMIS calibration program was not working. 224599 Projection features were not always correctly validating input features. 224587 Autosave to a file ignoree the text only mode. 224581 Unhandled exception errors could happen when the probe reached the end of the scan. 224575 After keying in xyz values while in polar produces, incorrect probe position, arrows, vector, etc. were observed. 224545 All references to a renamed feature did not make corresponding change in the edit window when the feature was renamed. 224515 Uninstalling the version and restoring the backup version was not working. 224508 Chorus DMIS Import of GETTEXT(155,0,APP_PTR) didn't get resolved. 224361 Editing an AutoLine input wrong values. 224360 Auto planes created online could have different Target and Theo values. 224336 Toolbars did not update when new toolbar buttons were added programatically. 224238 Auto Cone Height worked differently than height on an auto cylinder. 224235 Emergency Error happened while executing a Calibrate/MultipleArm command. 224139 Hit arrows did not adjust to the relative size of the corresponding hole. 224138 The Display Hits function was very erratic when dynamically adjusting the hits. 224085 Some Catia5 files could not be translated. 224068 Circle's angle vector changed when going back into dialog. 223901 Changes to Initial and Perm values in the dialog via the keyboard did not transfer to the command created in the Edit Window. 223785 T value computation for Edge Points was incorrect. 223737 Summary mode tree icons did not always properly indicate for expanded or collapsed trees. 223652 Some user defined command lines could not be created (ex: "E:\PCDMISW\36\bmwMess.exe /Input") 223633 Blank labels were being allowed for feature names. 223517 Prompting of executing iterative alignment features happened twice when executed from a script. 223428 PC-DMIs is crashing when clicking Undo with the UV scan dialog. 223341 Wrong movement during measurement of hits without the direction of a Chorus DMIS program. 223203 Edge point Trigger Plane problem happened with the Krypton machine. 223156 Bookmarks could have been removed following a program execution. 223101 Probe definitions in DMIS export were incorrect if UsePostOutCode was 1. 223093 Sample hit in Auto Circles are now editable combo boxes. 223084 The Sharpe interface wasn't working correctly if absolute speeds were being used. 223006 Some surfaces could have been lost importing IGES files. 222780 Font and Fontsize for the Analysiswindow Hyperreport wasn't changeable through the object-properties. 222398 Polar Radius result values were not updated to the last execution of part program PDF output. 222203 Wrong code was seen after importing a DMI file if the SNSLCT commands couldn't be resolved. 222190 It was not possible to select square slots with the Unigraphics DCI. 222169 Problems with piercing surfaces with r10-r12 on Catia V5 models were encountered. 221935 Importing a DMIS MEAS/SPHERE in case of MODE/AUTO was creating an autosphere with the incorrect number of hits. 221934 Importing a DMIS MEAS/CYLINDR in case of MODE/AUTO was creating an autocylinder with the incorrect number of hits. 221878 Unmarked scripts were being executed. 221862 It wasn't possible to paste a valid pathname to an assignment or script command as a parameter. 221759 Step Mode execution froze when it reached a DISPLAYPRECISION command. 221671 Recall Viewset menu option had the wrong icon. 221200 Copy and paste of an offset point caused an assertion failure. 221189 DCC Notch went to manual mode when length of slot was less then the probe diameter. A warning was added. 220570 Analysisview screen capture wasn't drawing with the portrait option. 220554 Highlighting one tool in the rotary table calibration dialog, pressing Delete, and it would delete a different tool in list #1. 220441 Leader lines didn't update when a report was serialized in. 220195 Unigraphics feature labels were not being carried over into PC-DMIS. 219881 Basic Scan now generate hits if they are created without measure checked. 219561 Auto feature display hits functions have now been replaced with dragable path lines. 219412 PROF16 was OUT of Tolerance after a DMIS import without having been executed. 219411 If a DMIS file was opened by WORD, when loaded into PC-DMIS, the probe file name would be incorrect. 219262 Save As via automation was not working properly. 218069 DMIS programs were losing dimension format information on reposting to PC-DMIS. 217629 Filter sets could not be constructed from multiple scans. 216802 The SMX laser interface was upgrade to support 3 measurement modes. 216655 Dimension Infos were fixed so that they correctly remember their visibility state when switching viewsets. 215563 The Axila interface was not properly loading previously qualified probe diameters. 214826 If you create a basic scan without measure checked PC-DMIS will now automatically generate the hits. 214356 All scan data can now be sent to Point Cloud objects instead of being stored it in a scan. 226722 Problem with properties having no affect on Hyper-Reporting objects 227098 Ability to resize the Create fixture window 216802 Added measurement modes: interferometer only, interferometer set by ADM, and ADM only 227212 Optimized path success is given in terms of percentage rather than measurement 226273 Importing Unigraphics files is more efficient 226941 Auto Feature ID is displayed correctly with a CMT probe. 226654 Linear open scan was causing error during execution 226354 AutoCircle - First measurement of a 3.5mm hole with a 3mm stylus would come out of the hole and miss the part for the first hit. 227223 Jogbox done would close window rather than read pos while in multiple calibrate arm mode 227400 Clearplane works in conjunction with an autoplane feature. 227180 Autofeature dialog will now open when using ctrl-f when a laser probe is attached 226755 The output of a generic feature was producing wrong dimensions 226128 ADM tab of Machine Options dialog box changed to "Aiming" to aid in finding needed commands 227299 Auto circle and auto cylinder not using sample points to adjust probe hits during execution. 226994 AutoCone: Regenerate path on auto cylinder with user defined hits moves hits down in Z each time. 227369 Unable to select the correct probe in the auotcalibrate dialog in master/slave mode. 227609 Serialization issue with Part program that calls a basic script. Saving and reopening causes error 227276 Execution 'restores' a maximized Graphics Window rather than restoring previous window size 227085 Create features from DES points, depending on certain characters in the DES label. 214983 Machine collides with AutoCircle-Stud after read position 227562 Feature's ID is "0" for all features imported using "Chorus DMIS" (but it's correct using "DMIS") 227474 When using the FIND commands as part of the Auto features dialog, the priority surfaces are now being honored 226789 Recalling default layouts causes toolbars to overlap both 226932 TAB command not moving to correct location in the edit window 227696 Autoline is is measured as a circle when using auto dimensioning 227613 Recall button on true positions: a datum becomes the feature to be dimensioned. 227684 Autofeature: Disable view/hide probe path button when in manual mode. 226860 When using the Loop command, sebsequent iterations of the same command become slower and slower. 226752 During Collision Detection the probe rendering is made in a wrong position and with a wrong orientation. 226954 Double clicking the source file as part of the Operation/Rename process gives an application error. 227608 Error after deleting BASIC script command from the edit window 227690 Autosphere exported to Dmis and back would not execute 227433 After CAD replace, PC-DMIS will not import a part that was merged or replaced earlier in this PC-DMIS instance 227313 Graphics performance seems unusually slow with this model and is drastically slowing part program execution 227620 After importing this file the CPU stays at 100% 226627 The values that are displayed, requesting sample hits are not accurate for AutoEdgePt 226773 Results suddenly change in Perimeter scan when the path direction changes 227784 Page Up/down don't work the same for Summary mode as it does for command mode. Cursor does not stay on command, so EW does not remain live 227683 Autofeature: Disable Parallel/Perp view buttons when there are no probe path lines 227633 Imported DMIS files ignore the Inner/Outer flag for cylinders, circles, cones, ellipses, and spheres. 227787 Application Error with QuickStart + Undo 227533 With The autoslot dialog open, hit Alt - to delete hits. Hits keep returning to 4. 227057 Autofeature: Init Sample hits were not taken 227420 The Leapfrog menu item is disabled when it should be available 228089 AutoCornerPt: The the vector in command mode is different than the vector shown in the dialog 226348 Hide Feature Labels is crashing PC-DMIS 226405 Program executed from VB has pcdmis taking 100% CPU 227981 Autofeature: with ACTL thickness measures at the wrong location 227988 AutoEdgePt: Pathlines: Surface approach seems wrong before creation 227083 Confusing dialog box message in BF Recomp Circle in regards to the IN/OUT options 225817 Wrong measurement of a circular pattern of 8 holes - Chorus Migration 227758 Loading this UG model only shows wireframe data in PC-DMIS but has surface data in UG 227954 If, after a MOVE/ALL execution interruption, you decide to continue the three axes probe will reach a wrong position (very dangerous). 228101 writing data to scan object using basic scripting somehow changes the values 228406 After doing cad equals part, the set active page on the probe tool box was getting called causing instablity 228203 Roundess of Gauss sphere does not update on program execution. 228231 program sits idle after 4th scan during exeuction 228050 While testing w/ 2.16 DLL -- PCDMIS 3.7 rc and UseNewCancel = FALSE on an SMP300 D8 Series I CMM : Error 13 messages occuring and shutting down controller. 228435 SP25 Does Not Calibrate Properly in English unit program 228385 SP25 prbe data saved to v35 format is lost, but probe dialog still thinks it is calibrated 228416 Default executestate.dat file not being used. Not being copied like other .dat files. 228604 AutoSphere/Cone: Creating one via box select when dialog is open crashes pc-dmis 228584 It takes two clicks to select a CAD element now. 228257 Wireframe; hits created outside circle when I click inside with CATIA DCI 221874 Wrong measurements in POLAR coordinates 224388 Temp Comp sensors cannot be read from the controller 224441 Error during 2nd DMIS Import with REPLACE function. 225140 Saving program with TP dimension after deleting datums from edit window, Reload of program gives serialization error 225573 INITIAL and PERM values shold be to zero for imported DMIS files. 227532 Error when reading in assembly from CATIA 5 227601 application error after executing and then quitting out of nested sub-routine main program 227751 Autocalibrate Multiple arms on the horizontal double arm with cw43L and TP2 228029 AutoVectPt: click on a model, I have to use the END key twice on the keyboard to create feature. 3.5 MR2 only once is needed. 228155 Bad Install for Tesa Visio - Clean install of 3.7beta with new matrox meteor framegrabber 228269 When working with NC-100 sensors, in the Autofeatures windows either the not used or not implemented items are available to the operator. 228332 Inserting a Loc dimension gets a cryptic message. 228447 Select LIN4 graphically in the program results in no highlight, then highlight on second click, but LIN4 gets labelled "2". 221015 Clicking on features in the graphics window is not highlighting in feature list dialogs... 228389 Problem with Rotary Scan 228497 Arm2 opens with a wrong axis orientation. 228539 Contour plots have several issues drawing the profile graphical analysis 228628 Autofeature: Wrong data in the dialogs 228743 Autofeature: Installing Offline (typical demo style portlock) - Auto options are hidden 228235 Bug: Create a line feature, hit test on AF dialog, at end of test, PCDmis crashes. 224795 display a 3D distance from the probe to nearest CAD surface, highlighting the CAD surface used 228404 Cannot open read-only files. 228784 CAD Solid did not come up, after 3D rotation with middle mouse button 228607 Missing LEITZ section in Setting Editor 226680 "File | Quit" does not close part program correctly after creating part program via automation 228342 Layer Informations get lost after closing and reopen the part program 228580 To edit and modify a measured cone will reverse it 228587 "Mark Used" and "User Defined Calibration Order" checked, will cause an Application Error 227443 Create CMT Auto Feature (N+1) after Capturing Auto Feature N 226108 Wrong Message in Status Window, If you have a dimension right after a feature 226151 Probe Readout Windo Frozen 226242 deleting a surface and then deleting another surface under the first causes application error 227007 collision detection has problems with DCI models 227286 Multiple arm management and the probe 228828 Insert Move Point after LOADPROBE\ and before TIP\ will cause an Access Violation. 228934 Iteratove alignments do not work with AF circles and Measure All Always checked 228303 Catia5DCI; Findnoms with autofeatures is not working 228477 FCR25 probe change crashes 228623 Dual Arm Mode, commands assigned to Arm1: execution not performed or hanged up 228696 Autofeature: Polar entry... cursor jumps to begining after decimal point entered. 228713 application error after using ".HITS[1.368] in construction 228950 Cad Camera programming broken in Curve mode 228136 Using the Quick Fixture toolbar icon after the Text Box Mode icon defaults back to Translate Mode 228183 Major delays when trying to load this 3.5 MR2 part program (700% slower) 228680 NC-100 Auto Features don't work correctly if the pp Measurement Unit is Inch 228932 Error "seek failed on an unnamed file" during execution causes pc-dmis to hang 227727 Colors are not working on vector hits in scan 227524 F1=A icon in the Hyper Report Object Bar does not return edit feature text as expected 227308 Application error when Generating Patch Scan on surface data... 226974 AutoSurfPt: AutoMove "AFTER" (only) moves to 0,0,0 228597 DMIS Import corrupts Arm1 Probe File 228848 It is not possible to activate Arm2 228561 Missing leader lines when the print to PDF file with HR inline - PDF printer seems causing this 228986 F3 unmark but doesn't mark 228959 Executing a Qualification Check hangs PC-DMIS. 228616 Learn hit during execution cause "Fatal controller comunication Error" 229029 Application Error on the View Setup Levels. 228955 Active arm changes when going from Command Mode to Summary Mode 229102 Incorrect information in the probe dialog is causing the operators to destroy their calibration data and the parameter sets 226804 During animation path, the inside the loop, Animated probe, label, path lines are moved to a wrong location 229209 Parameter Out Of Tolerance' during partial Arm2 execution 229138 Text in EditWindow changed when switching between summary and commnad mode 228824 'TR_OUTOL Machine Parameter out of tolerance!' error when performing the 'Load active Probe' command, when the unit is set to INCHES 229168 Autofeature: click on DES points + show path lines = application error 227990 AutoAnglePt: new Pathlines incorrect during cad selection. Fine after creation. (Interior/Exterior button) 229154 The app hangs if they press Cancel in an operator comment during execution 228771 Can't assign all dimensions to the correct arm environment 229209 The green buttons Active Arms disappear when the New-Part-Program dialog is open. 229339 Deleting non-contiguous commands in summary mode causes PC-DMIS to crash 228722 The app is crashing when they change the tolerance on a dimension 228733 Missing 'probe confirmation' dialog on Arm2 228897 Can't partially execute a block - the execution starts measuring the features of the iterative alignment 228836 Crash occurs when partially executing a circle with CRTL-E 229164 The 2nd inline HyperReport to a PDF file is always 'broken' 228741 The move speed parameter in absolute mode does not have the expected effect for Mitutoyo Controller 229121 Error indicating "Probe data not available" after switching from SM25-1 to SM25-2 229281 Executing a change cycle with the SP25M requires operator to press Stop/Continue 227373 Auto feature dialog - ComboBox for element selection is losing the focus when pressing UP and DOWN 228062 Support added for the LSP-X3 probe 224575 keying in xyz values while in polar produces incorrect probe position, arrows, vector, etc. 225731 Dimensions formatted with Min/Max become corrupted in the report 224659 The graphical radial outline has been fixed for AutoPlane 228430 Getting a "unable to open ph10mq draw" when I open 3.5 programs. 228443 Insert/change alignment before location dimension, dimension does not update 228612 When alignment is recalled prior to PT89 in the program, and answer NO to update, PC-DMIS still updates the alignment anyways. 228785 Construct plane using auto vector points, doubleclicking feature after cursor position crashes PC-DMIS. 227699 Dual arm pp and Arm2 active: the probes and probes position are shown alternatively (arm1 and arm2) 227458 Clicking start - direction - stop points on a wire does no work 228661 Hyperreport with "use all viewsets" causes crash 229820 Their HyperReports creates always bad PDF files 227710 The GOTO keyword does not implement the ARC and POL minor words 228485 Support added - DCI for CATIA V5 R14 227971 Many DMIS vector functions are mistranslated 226798 Application is crashing when they execute a pp where a comment contains the '%' character. 231179 Creating an iterative alignment from the attached dual-arm program features will hang PC-DMIS. 230835 After the changes in #230635 the calculation of an profile with the setting best fit is wrong 230720 Autofeature: RMeas applies rotation from the relative feature to the feature being measured not just translation 230331 application error using ctrl-X to attempt to re-locate a BASIC script command object 231973 After Dual-arm session, Automation opens single arm part program on arm 2 OFFLINE 231553 Scans created in 3.2063 do not run in 3.7. 231563 External points are not going into the dmo output file 226824 Perimeter scan is too slow to use 231099 cannot find CAD when taking hits on certain surfaces 231993 AutoSphere: AutoCone: app error diameter or angle = 0 230023 CPCDbc_geom::DropTessellation() not reporting when drop is on surface boundary 227623 PC-DMIS crashes when executing a Vector Point in FindNoms mode 234085 Unusable nominal values when I click wireframe slot 235825 An "End of Measurement for" statement is being inserted between the LoadProbe and TIP/T1A0B0 statements in New part programs 235823 "Scale to Fit" doesn't work correctly when using UG Assemblies & the PCDMIS Assebly button 236924 FUNCTION/HEM0 not importing properly from Toyota DMIS Script. 236743 After export of Toyota Part program to DMIS, it export incorrectly with UseToyotaDmisConvention=True ----------------------------------------------------------------------------------------------- Version 3.7 Maintenance Release 1 - March 11, 2005 229645 SP80 probe file is behaving as if it were an articulating wrist 229556 Error when programming from CAD for large features. 229512 Equate Alignment does not work 229315 CRASH w/ SP25 in INCH part during tool change 229555 Temp Comp Setup dialog doesn't retain material coefficient, treshold and temp comp enabled check box 229264 Many part programs seem to be loosing their ClearPlane settings even though they have run fine hundreds of times before. 229854 Change needed to support optical configuration of Mycrona 225904 Need to add IsHomed() API call to motion HAL section 229366 Please see attached document and cat part for viewing discrepencies between PC-DMIS and Catia 229415 Clicking Find in the Auto Vector Point dialog after slight edit in X, Y or Z field returns 0,0,0 for all axis? 229313 Cant' control staring angle of Basic Circle Scan 229604 Krypton Interface doesn't work in v37 Release 227274 Add support for probe calibration on 7-axis arms 229903 PC-DMIS crashes when clicking on LIV to program a feature 229821 App is crashing when executing the attached multiple arm pp in step mode 228778 Probe Compensation on a small OD is not correct 229652 TESAVisio Cad File can't select some edges properly 101562 Change Optical Calibration routine to use new Hexagon Glass Slide 229936 A input delay in an operator input dialog on arm2 is crashing the app 229586 Changing Nominal on True Position during offline execution 229708 The options in the ‚Print Options' dialog are changing themselves during pp execution 229803 AutoFeature:Corner PT RMEAS not working correctly. Measuring from RMEAS feature Theoreticals. 229802 RMEAS AF: Line not working correctly 229801 AutoFeature:Plane RMEAS not working correctly. Measuring from RMEAS feature Theoreticals. 229746 RMEAS not functioning correctly 229662 Openning attached program crashes PC_DMIS. 229695 The Arm1 app is crashing when launching the attached pp Online on machine DEA1 (Bravo) 229425 3.7 Release has the wrong version of JOHANSSON.DLL (1.102 instead of 1.103) 229396 Prompt to position probe clear for feature do not appear when doing an iterative alignment with measure all once selected 230048 Wrong probe offsets for the LSP-X5. 230084 A conrol from a different dialog is obscurring the calibration instruction field on the Illuminatin Calibration dialog 229997 Several problems with dimensions during the execution of an AUDIMESS iteration 230120 Reinstalling PC-DMIS overwriting optical calibration files 230129 Cut down menus TOO cut down 229144 AutoLine: edge vector wasn't serialized 230087 Having TESA Custom toolbar installed breaks Add Ins toolbar 229820 Their HyperReports creates always bad PDF files 230150 System hangs after ‚readpoint CRTL-G' operation - must be shutdown with the task manager 230111 AutoLine is fine in original v37R, but in v37b the depth parameter is ignored, it always uses 0 230109 We need connector type "SM25-4" added for probe.dat. 229686 Wrong separator in DMIS Export for PTMEAS lines 230217 Perimeter Scan goes in wrong direction 230233 AutoVectPt: Flip Vector changes coordinates. 229553 AutoVectPt: Targ Vec not equal to normal vec after click on cad 229552 Autofeature: ID disappears in dialog when clicking a XYZ point 230092 A lot of Vision related dialogs/text not translated into Chinese 230239 Automotive deviation letters in the Dimension info boxes does not match the report 229466 Some surfaces lost for UG DCT 229323 When he opens a part program in 3.7, that was created in 3.25, he is getting an Out of Memory error. 229229 Autofeature: No subsequent default ID's after click on DES Point 229713 Some UG PRT file can't create features 229712 UG DCI can't find the tips collision 229966 Using MMC on tertiary results in more deviation rather than less as expected 228576 Bad display of "Edit Window Colors" in French 230340 Their calibration pp doesn't execute in MR1 RC. Arm2 execution stops with 'TR_OUTOL. Machine Parameter out of tolerance'. And besides is calliper at Arm2 defect. 230202 Application error on startup with attached wrist map files. 228434 The Hasp driver fails to load on a Dell Computer 230304 DCT is not importing a very simple assembly correctly 230388 FEAT/ARC in their DMO files - QUIRL can't import these files because the feature type ARC is not supported 230479 Circles constructed from basic circle scans don't have the right diameter 230230 Dimensions shows different values than the related feature after the pp execution 230231 Arm2 execution doesn't start the execution of the PCD iterative alignment 230342 Large Assemblies are displayed in an exploded view...but, they are fine in 3.5 MR2 for example 233610 RECALL/DA(CARCOR) gets resolved to different PC-DMIS commands Merge recent changes for Leitz, Romer, Sharpe and Sheffield interfaces. ----------------------------------------------------------------------------------------------- Version 3.7 Maintenance Release 2 - June 24, 2005 228762 DMIS output created with the DMIS out wizard does not have FILNAM statement 230677 On dimension LAGE1__ the reference feature changes during pp execution 229820 Their HyperReports creates always bad PDF files 230038 operators are getting nominal values from hidden UG-DCI surfaces 230036 Can't pick on some of the surfaces of a UG file imported via the DCI 229269 problems with DES polylines 229608 AutoAnglePt: Graphical black dot in off in CAD by a probe radius after selection (was Selection not working for rounded corners) 230835 After the changes in #230635 the calculation of an profile with the setting best fit is wrong 230635 PCD crash during a partprogram execution 230979 Manual Focus doesn't always return a value and repeatability is poor 101925 Linear error range exceeded Neil Kay 231069 vision stage cal error where old volcomp active during calibration data collecton Bryan Seltzer 231010 AutoLine: Edge Vector not being serialized. Glenn Russell 231068 Standard error code processing shows no messagein message box Bryan Seltzer 231051 using Loop and assigned values to rotate alignment OK in 3.5MR2 Not working in 3.7MR1 ! Steve Barber 230779 PCD doesn't raise the OnEndExecution event Alberto Piolatto 230751 Probe Head orientation changes during measurements Alberto Piolatto 230802 True position dimensions are not correct after execution in 3.7, programmed in 3.5 230418 Midplane XYZ is incorrect. It looks as if the centroid is calculated as the cast center, instead of the actual center. This caused thousands worth of time/effort. Problem exist since 3.5 at least. 231179 Creating an iterative alignment from the attached dual-arm program features will hang PC-DMIS. 230720 Autofeature: RMeas applies rotation from the relative feature to the feature being measured not just translation 230265 Program created in 3.5 is not evaluating True position correctly in 3.7 230246 Bonus tolerance not included in final bonus tolerance when perpendicular to centerline option is checked 230734 error in best fit calculation 230778 Partprogram shows wrong distance values for funktionsmasse. 230866 How to lock Z in TP DRF 229919 When loading a program that has a TP with Graphical Analysis on, the graphics are drawn incorrectly. 231270 After the import, the bestfit alignment seems not to work. 229959 RE: Scans built by scripts that worked in 3.5 MR1 but will not in 3.5MR2, or 3.6MR1, or 3.7RC 231471 Autofeature Pre-Hit don't works with loop 231006 Optical Calibration fails every time to find first target on VISIO 231013 box-select fails with DES polylines 231609 AutoCircle: Find Hole - "Center" plunge too deep 231190 True position problems.... or questions 231563 External points are not going into the dmo output file 231047 How to don´t show the message "Current Probe" 221267 Find Hole: in combination with CENTER for Autofeature Circle/Slot measures related to the NOMINAL hole and the defined Depth 231652 Assign with a set of values generate pcdmis Crash Ok in 3.5 not in 3.7 Mr& or Candidate Mr2 231830 B&S PCI file XNPCI09.dll not up to date in release 231553 Scans created in 3.2063 do not run in 3.7... 231973 After Dual-arm session, Automation opens single arm part program on arm 2 OFFLINE 230331 application error using ctrl-X to attempt to re-locate a BASIC script command object 231875 Ellipse is constructed incorrectly 229775 The system is slowing down during the presentation if GRAPH=ON on dimensions on Scans 231684 Unable to learn features using preview window 230875 The dimensions are not refreshing the latest measured part 231993 AutoSphere: AutoCone: app error diameter or angle = 0 231099 cannot find CAD when taking hits on certain surfaces 232028 Update AP_COMP algorythm 231016 Autofeature: DES ID lost when feature type is changed in the EW 231917 Pcdmis loses sometimes the "CAD Reference" 231529 Probe radius will be used from Offline program 231475 Probe Comp is not working in some areas for this part program... 231101 all parts export to the AS3 file, ignoring the CAD assembly 231626 Measured line does not solve correctly with constrained vector. 231582 Fitting and potential bonus application problems... 231902 alignment using two nominally parallel cylinders has wrong rotation when meas vector of 2nd cyl has very small i,j compoments 231440 In v37R and v37MR1, using the Hard Probe or manual TESATAR probe, it is NOT possible to scan 230255 Edit window gets undockable to the left of the app window (opens always only maximized in docked view) 230023 CPCDbc_geom::DropTessellation() not reporting when drop is on surface boundary 232410 Iterative alignment - Datum Error reporting all points are to primary axis 230900 Error in the arm2 window " temp comp setup dialog " in modality duble arm 231121 Importing modifiec IGS file, all the hyperreports in partprogram loses the image. 230276 Dimension D168 and others are missing in the protocol (on paper and in the PDF file) 101989 Metronics vision interface needs to be added to the build/install 232667 Bottom light frequently flicking to 0 intensity, even though light itself is not 232776 FindHole Center method not storing values after READPOS crashing the machine... 232622 Variable handling does not work in 3.7 MR2 as before - compatibility problem 232777 Problem calibrating indexable table 232399 They can't find a setting to avoid that their dimensions from the iterativ alignment get printed to the DMO file. 232737 The probe head orientation changes during partprogram execution 232294 The tips it their probe files appears multiple times after executing the pp with the 'supervisor' 230384 The execution of the auto/calibrate probe command creates bad tip offsets - during the qualification check the probe is crashing the sphere therefore 232714 AutoCircle: sign of pitch changed between 3.6 232951 Trying to connect to this model crashes PC-DMIS... 233011 RMEAS/ CIRCLE, F(C1_____R), 4, FA(F1_____R) creates a incorrect PC-DMIS command in V37 231042 Displaying Path lines crashes PC-DMIS 233092 Cannot manual TTP scan with 3.7 233255 Using Quick Starts to align with Romer Arm is calculating incorrect vectors 233835 DMO wizard creates an incorrect output 235777 take the PNT TOL value and apply it to the PNT TARGET RAD of iterative alignments ----------------------------------------------------------------------------------------------- Version 3.7 Maintenance Release 3 - NOv 15, 2005 102222 Optimize DMIS Translator for Toyota Part Programs 102223 Add new methods / command flags to allow ease of tracking missed/unexepected hits 228846 Any effect pressing the buttons SETUP and PARAMS of Quick Start 229027 Nominals mode not working 229078 Autofeature: RMeas: CadSelection not allowed after RMeas Dlg OK 229268 GM is not able to cut-and-paste without having both part programs open at the same time 229465 While looping, the program measured side hole 1, 3, 5 and etc. (Keep skipping the interval 2, 4, 6 and etc,...). 229630 'Scan Probe Compensation FAILED' error at the end of certain patch scans 230387 Won't translate the geometric command 231723 AutoVectorPt, AutoSurfacePt: 'Snap Point' not being remembered 231910 SP600 probe on Arm2 is not enabled - probe crashes the sphere 232043 AutoVectorPt: during learning with "Polar" selected, RAH values incorrect (online) 232294 The tips it their probe files appears multiple times after executing the pp with the 'supervisor' 232752 symmetrie only in workplane z 232853 Multiple labels and features in the graphics window from one feature in the program. 232959 Auto report use an AutoZoom 232965 Last Execution Report Mode 233001 Option -> UseTestPos need the administrator privilege 233043 v3.7R & MR1,,,Graphics image does not get to the printer, but the labels look nice 233255 Using Quick Starts to align with Romer Arm is calculating incorrect vectors 233266 Wrong nominal values 233315 new layouts problem with new function 233316 AutoEdgePt: with shank probe wrong compensated 233350 Profitech Interface 233511 Comments and dimensions is the DMO file are sixes and seventh 233610 RECALL/DA(CARCOR) gets resolved to different PC-DMIS commands 233835 It appearss that the DMO wizard creates an incorrect output 234085 unusable nominal values when I click wireframe slot 234237 Tolerance in dimension is changing itself 234271 True Position results wrong. Diameters for datum features reported incorrectly 234316 3.7 MR2 Crashes on Patch Scan 234422 Changing the feat type in the dialog gives new default label... bad when selected DES 234566 Basic Circle scans fail when HSSDAT disabled 234569 Part Program won't open 234589 Opening a second PP on the Master PC it's not in offline mode but in CMM2 mode 234633 Problem with different measurement results obtain from v35MR2 and v37MR1 and MR2 234679 The diameter of cylinder in True Position callout is giving bogus numbers 234691 PC-DMIS cannot run this part program (and others) for more than 2 hours... 234746 Undo function after CUT is FUBAR 234770 error with OD BasicCircle scans if init-vec is orthogonal 234779 DCI - Cat V5 - pc-dmis will not open up a DCI created prog if DCI is not available. 234784 Getting : Could not Create CAD error. 234855 On-Error in AutoFeature dialog mis-behaving 234915 Import from a DMI File switched to autofeatures circle with the currend values 234938 AutoPlane: changing the Angle Vector does nothing 235029 Unable to delete script, causes program to crash 235100 The diameter of cylinder in True Position callout is giving the wrong nominal value when open a pp 3.5 MR2 235359 AutoAnglePt: PC-DMIS crashes when trying to insert 235467 Incorrect results in their DMO files 235526 T-Deviation at -0.062 is incorrect - this is the wrong for ALL their T-Deviations 235531 F9 on Probe command in the attached program takes 3 to 4 minutes 235533 Midplane construction no longer works as it did in 3.5 MR2. 235537 Alignment part program doesn't iterate as expected 235540 Please add option to the ON-ERROR Function to search down the part program first instead of up. 235569 FARO Interface no comping correctly on anything but the Z (alignemnt) workplane. 235589 True position calculations are wrong in MMC and LMC 235602 Circles not tip comped correctly in quickstart alignment procedure 235604 Can nnot merge UG DCI files on import after deleting CAD elements 235615 Edit window Blank after program execution. Can't close or quit. 235718 Perpendicualrity & parallelism dimension not reporting OOT correct for feature size 235823 Scale to Fit doesn't work correctly when using UG Assemblies & the PCDMIS Assebly button 235869 This part program will not open in any version after 3.5 MR2... 235887 The import of a chorus dmis file is wrong 235929 After an emergency the wrist have to rotate to the current tip 235992 PCDMIS crash executing partprogram 236068 Setting the CAD to a solid wireframe, and then measuring an AUTOSLOT, freezes PCDMIS. 236074 Multiple instances of the same feature in the DMO file is making this file unusable for the later import to AUDIBILD and Oracle 236181 AutoEllipse: Stud - Machine Drives into interior (probe crash) due to poor circular moves 236232 Basic scans not available with the PC-DMIS CAD w/DCC scanning option 236493 Crash selecting features in True position dimmension window 236496 Incomplete dimension display in edit window and hang when deleting it. 236518 Changing the offset values for the translation alignment was shifting the offset twice 236539 Faro Laser Tracker 4500 Interative Alignment Problem 236569 Application Error appears, using a VB program to create a Feature Point. 236574 When they change the tolerance in a dimension the label name of the tolerance remains 236612 PCDMIS crash cancelling partprogram execution 236629 Memory over write in UG DCI 236630 Profile dimension not working for Vision features 236677 Dmis Import for VWSA not converting probe orientations correctly. 236721 Cad Distance To Target indicator often hidden for Vision 236814 A lot of message boxes converting a measured scan to points 236823 WaitUntilExecuted is throwing an exception in this Toyota Script file. 236865 Fixed Distance Scan with Romer Arm 236918 PCDMIS crash changing from command mode to DMIS mode in edit window 236924 FUNCTION/HEM0 not importing properly from Toyota DMIS Script. 236981 PCDMIS crash executing a feature with CNTRL-E and then cancelling execution. 236992 AutoPlane: Pattern not serialized 237026 Commands from previous run of a basic script execute even when basic script is no longer marked 237030 When you copy a script that has all of its commands hidden and then paste, commands pasted in aren't marked as commands belonging to the basic script 237051 Loding Report phase much longer and Graphics slower than previous versions 237059 Bad pagination of PDF reports 237109 The DMO file created with the EXTERNALCOMAND/DMIS_OUT.EXE is not in sync with the part program 237129 need Catia5r16.dll added to v37r, v37, v40, and v41 install sets 237136 Move Sync command is assigned only to the arm2 237139 Alignment command on arm1 feature in the arm1 environment is partially assigned to arm2? 237356 After executing Toyotas part programs with new changes, PC-DMIS crashes often after executing part. 237404 pc-dmis CRASH after executing program and File / Close 237440 Cannot import catia V5 R15 catpart. 237543 Incorrect installation for the Metronics interface