––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– Wilcox Associates, Inc. PC–DMIS® Version 4.2 Enterprise Metrology Solutions Installation Notes: ––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– 1) General System Requirements 2) Information about this release 3) New Product Information 4) Release Notes ****************************************************************************************************** ****************************************************************************************************** 1) General System Requirements Minimum Requirements: - PC-DMIS® 4.2 operates under 32-bit Windows2000 or WindowsXP and the 64-bit (x64) WindowsXP systems. No other operating systems are supported. - Pentium-IV or higher processor is suggested. - 1 GHZ or higher Intel processor. - 512MB of RAM is recommended but significantly more may be required if working with large CAD models. - 500MB of free hard drive space minimum for the application. - SVGA capable monitor. - CD-ROM drive. - USB port available. - The computer must have a graphics card that supports OpenGL shading. We cannot specify an exact graphics card since every user has varying needs. However, nVidia is the preferred graphics vendor for PC-DMIS. - Nvidia GeForce video cards are not recommended for use with PC-DMIS. This is defined as a "gaming" card according to Nvidia Engineering. - Supports a screen resolution of 1280 x 1024 or higher. - RTF file output requires Microsoft Word to be viewed. Recommended Minimums: - 32-bit Windows2000 or WindowsXP and the 64-bit (x64) WindowsXP systems. - 2 GHZ or higher Intel processor for improved performance. - 1GB of RAM or higher. More RAM may be required if working with large CAD models. You should have RAM equal to 8 times the size of the largest CAD file you will use. (For example, if you use an IGES model of 250 MB, then 2 GB RAM is recommended.) - 1GB of free hard drive space plus allocated Virtual Memory of 8 times the largest CAD file used. - SVGA graphics card that supports OpenGL shading and that has WHQL certified drivers. On board video card memory should be based on the size of CAD file being used. - For small CAD files (less than 50 MB), 32MB video memory. - For medium CAD files (50-100 MB), 64MB video memory. - For large CAD files (> 100 MB), 128MB+ video memory. WHQL (Microsoft Windows Hardware Quality Labs) video drivers can be downloaded automatically when using the Windows Update software. - SVGA capable monitor. - CD-ROM drive. - USB port available. - Supports a screen resolution of 1280 x 1024. - NOTE: Depending on your specific needs, the recommended system specifications for this version of PC-DMIS may be much higher. A more substantial computer system may be required to accommodate part programs using Automation or complex Reporting objects. Be sure to consult with your PC-DMIS distributor to find out the type of computer system you will need in order to run this software at its optimum capability. - IMPORTANT: When using 3rd-party drivers you should contact your local Hexagon representative to ensure Operating Sytem compatibility. ****************************************************************************************************** ****************************************************************************************************** 2) Information about this release. We at Wilcox Associates are proud to bring you this new version of PC-DMIS® 4.2 This Enterprise Metrology Solutions platform brings together new aspects of PC-DMIS® for the development of a complete manufacturing process control solution. Available in this release are variations of PC-DMIS® designed to assist with every aspect of the fabrication and quality control process. The newly created packages include PC-DMIS® Laser, PC-DMIS® NC, as well as the established PC-DMIS® Pro, PC-DMIS® CAD, and PC-DMIS® CAD++ platforms. Also included with this release is PC-DMIS® ONE, a simplified shop-floor DCC inspection package developed in cooperation with Brown & Sharpe. The testing of this version has been significant. We’d like to take a moment to discuss this process and also make you aware of the various components of testing. Testing is comprised of two parts. These can be described as functional testing and integration testing. The vast majority of testing effort goes on in the functional area. This is the testing that determines that specific functions that are core to the software, regardless of what type of machine is used, are working correctly. The integration testing is essentially a testing of the interface with a particular type of machine. In the ideal scenario, WAI would have access to at least one of every piece of hardware that is operating in the field running PC-DMIS®. However, in practical terms, this is impossible. This integration test plan is then performed on as many types of machines as we have available. Unfortunately, there will inevitably be machines to which we do not have access and that cannot be fully tested in this manner. To this end we have made an effort at closing this gap by partnering with our customers through the Beta Test Program. On the following pages you will find an application for this program. We urge you to consider signing up for the program as it provides the mutual benefit of helping us create the best product possible for you, our customer. Should you experience problems with your system after installation of PC-DMIS® 4.2, it could possibly be an integration problem. If it is a problem of this nature, it will probably be evident immediately upon first use of the possibly untested configuration. Should such a problem materialize, you will be given the highest priority for correcting these problems. Please call Tech Support immediately to report any integration problems. For existing users of PC-DMIS who currently have earlier versions of PC-DMIS® installed, it is advised that PC-DMIS 4.2® be installed into a new directory. In this way, you can be assured of continuous use of the existing version should problems arise with this newer version. ****************************************************************************************************** ****************************************************************************************************** 3) New Product Information (Note: EMS products remain in Early Adopter stage until formal release of each is announced.) PC–DMIS® NCI – This product an Interactive version of PC–DMIS NC. It enables interactive connection between the core PC–DMIS product and a machine tool similar to that used with a CMM controller. –––––––––––––––––––––––––––––––––––––––Major Enhancements––––––––––––––––––––––––––––––––––––––––––––– >>>PC–DMIS Reporting<<< • New Custom reports that are created based on the part program and stored in that part program. • Drag and Drop capability of Summary Mode Edit Window with Custom Report. • Ability to open custom reports stored in part programs. • Conversion of legacy reports to custom reports. >>>PC–DMIS Graphics Display<<< • Graphic Item Toolbar - Allows you to toggle the display of the different label types within the Graphics Display Window (102556). • New Dimension Color Window - Displays the dimension tolerance colors and their associated values for quick comparison (102602). >>>PC–DMIS Portable<<< • New Leica Machine Interface tools - This includes new menu items, Bundle alignment, Tracker environmental display in status bar. (102710,102559,102562,&102550) >>>PC–DMIS Auto Features<<< • Improved functionality of Auto Feature dialog box. Many Auto Feature options have been moved to the Probe Toolbox which works in conjunction with the Auto Feature dialog box (241405 & 102662). >>>PC–DMIS Edit Window<<< • Improved Edit Window ease-of-use, visibility, and hypertext-like visualization (102621). • Improved capabilities for Edit Window Groups which allow nested groups and ability to collapse groups (102725 & 102618). >>>PC–DMIS Inspection Planner<<< • New stand-alone Inspection Planner application. Currently only supports CATIA V5. ****************************************************************************************************** ****************************************************************************************************** 4) Release Notes Version 4.2 of PC-DMIS is a significant development release of the software. Initial Release Date: October 2, 2006. **** Prior to the release of Version 4.2, Version 4.1 was last official release of PC-DMIS by Wilcox Associates, Inc. and the Brown & Sharpe Metrology Group of Hexagon Metrology. Notice: PC-DMIS Database support for Microsoft Access does not exist in Version 4.2 Miscellaneous enhancements: >>>PC–DMIS Reporting<<< • New feature-based label layout style (102466). • Quickly duplicate report pages (102467). • Ability to Hide labels in the CAD Reporting object (102667). • New Section Cut object based on a plane defined by an X, Y, Z and I, J, K (102468) • Labels can be created without color or border (transparent) (102465). • VB scripts can be added to the rule tree as a second condition (102677). • Customize the display of leader-lines in your report including dimension tolerance information (102631). • Collation of the different sections of the report (102630). • New boundary leader lines for distance and angle dimensions (102470). • New PC-DMIS ActiveX Controls (102471, 102472 & 102462). • Auto Zoom for CAD images in Reports (102475). • Use of Real CAD image in Report Layout window (102564). • Leader Lines can be drawn to the centroid of a feature (102566). • Report template object proprieties are accessible to label object (102477). • Feature data is accessible in dimension label expressions (102535) • View Properties for Form and Form controls (102568). • Ability to create a "Front" page for a report (102537). • Optimized grid property and ability to turn-off the border of Graphical Analysis window (102715, 102459 & 102539). • Rule Tree Editor has been improved for ease of editing rules (102464). • Ability to resize labels (102561). • Predefined page size can be defined for labels (102571) • Automotive deviation letters can be displayed in reports created from the standard report templates (102703). • New custom report command to allow inline insertion of custom reports into the current report (102717). • Ability to add custom reports to the reporting toolbar (102744). • Create templates and labels for the Audi style reports (102469) • Make reporting objects movable by the end user (102461). • Report template command inserted in the part program will take effect only for the commands between the current and the next report template command (102540). • Change properties to toggle fields for report objects (102460). • When the zoom size is small on the report window, layout the pages side by side and then down (102538). • Probing direction in the main direction of the CAD reference should appear as symbol on the feature label (102733). • Turn different scales back on the rulers in the report template editors (239830). • Add custom label to report page on-the-fly; e.g. the label that needs to show statistics (total dimensions, % out of tolerance, % in tolerance) (102675). • Corrected display of histogram objects dimensions. Fix dimension histogram object so that it draws correctly for (bilateral vs. positive only) dimensions • When exiting the Custom Report Editor, user is asked to save if any changes were made. • Opening Custom Report Editor forces Edit window into summary mode (102717). • Changes in the Custom Report Editor are picked up when the Custom Reports are refreshed (102714). • Enhancements in report display of 3D best fit alignment graphical analysis (241750). • Optimization of the grid property of Graphical Analysis window (102459). >>>PC–DMIS Dimensions<<< • Ability to Keep a Dimensions existing Axes values even when switching to a different feature type. • Flatness Dimension can be evaluated per unit area (102025). • Improved Symmetry Dimension (102155). • Ability to display the percent of deviation for dimensions (102676). • Two Direction tolerances can be displayed for Dimensions (102676). • Optimized Profile Tolerancing for Zimmer (102651). • Ensure that users cannot create dimensions from the dialog when no axes are selected (102611). • User configured defaults for dimension axes (102610). >>>PC–DMIS Graphics Display<<< • Ability to click CAD elements through a transparent machine. • Improved CATIA V5 translator. • Verification tool to check accuracy of CAD data (102546). • Ability to check and update CAD Point Nominal Deviations. • Specify Coordinate System by selecting CAD entities (102643). • Outlier removal and/or point highlighting in the graphics display – 102296 • Global update nominals from new CAD model (101898). >>>PC–DMIS Scanning<<< • Ability to control the drop-out distance around a hole for perimeter scans (102292/102622). >>>PC–DMIS Portable<<< • Improved default settings for portable devices, such as large size toolbars, menus, status bar etc (102548). • Sound indicators while scanning with Romer/Cimcore arms (102555). >>>PC–DMIS Auto Features<<< • AutoCylinder: remove Depth affect on Height row (240615). • Ending Depth added to Auto Cones to help prevent collision (240611). • Improved DMIS mode support for Auto Feature types (102613). >>>PC–DMIS Constructed Features<<< • Constructed Features allow you to specify theoretical values (102672). • Ellipse construction from a plane and cylinder intersection (102616). • Construct a Circle inside a triangle or based on a three circles (102620). >>>PC–DMIS Alignments<<< • 6-Point best fit alignment add to Quick Start (102530 & 102214). • Ability to control individual degrees of freedom of Best Fit constraints (102614). • Integrate the leapfrog transform (102615). >>>PC–DMIS Laser<<< • Auto Laser Circles allow you to select the math type used for creation (102655). >>>PC–DMIS DCI<<< • Pro/E DCI - Added support for Wildfire 3. • Added support for DaimlerChrysler’s ETool User Defined Objects (UDOs)through CATIA V5 DCI (102645). • Unigraphics Load Options can be changed from PC-DMIS menu (102633). • Unigraphics DCI – File open errors combined into one dialog (102632). >>>PC–DMIS Vision<<< • TESA Visio 300 DCC Homing DCC model (241928). • TESA Visio 300 Option to read settings from CNC.INI file (236126). • Initial Support has been added for CMM-V type cameras (100252). • PH9 Support added to Vision. • Edge Tracer - Automatic function to trace the perimeter of an object to create a 2D Profile feature (102578). • Target values added to Vision Auto Features to assist in locating a features actual location (226736). • New QVI/OGP Vision interface (102590). • Add Support for new Mycrona Controller/Libraries (251172) >>>PC–DMIS NC<<< • New Wilcox Macro set for Fanuc controllers. • Tosnuc 888 Control • Ability to receive machine corrective feedback during replay of a journal file • Ability to pass commands to the NC controller as a string. >>>PC–DMIS Gear<<< • Add Gear package to the PC–DMIS install set (102627). • For Gear package in production line, have an automatic report at end of the part program execution (102626). • Measure a Gear without any teeth (102625). • Be able to set the number of profile teeth to more than 4 (102624). >>>PC–DMIS Other Enhancements<<< • Cause the Part Sensor Number to be machine specific and not dependent on the part program (102617). • Message boxes are placed to avoid interference with execution (102619). • Make the Any Order Execution tolerances a variable which can be modified programmatically or disabled altogether at various points within a part program’s execution (102639). • Access added to the total number of pages to reporting expression and scripting languages (102601). • Tracefields can be imported from DMIS files into User-defined tracefields. • New measured slots (Square or Round) for PC–DMIS and Quick Start (102558). • Improved support for PS(label) statements in DMIS via Trace Fields (102612). • Boundary checking/detection for step size vs. sphere radius (102745). • Support for the TP200 and TP20 Tool changers with 3 slots (101984). –––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– Known corrections and improvements from Versions 4.0 & 4.1 that have been resolved: 211323 – Add RMeas to all Autofeatures 224915 - Creating/Executing multiple AutoFeatures consecutively with the Edit Window undocked casues it to grow 235617 – AutoRoundSlot: FindNoms mode not solving correctly when in Curve Select Mode (Online Leitz) 235934 – Sheffield Customer GE states spherical boundary conditions with scans do not stop with changes to radius or # of passes but always terminate scans at the center point of the boundary location. 236197 – Disable scan type - Rotary if its not supported in the Sheffield interface. 236362 – There is no CAD control available to the form template 236764 - Paste with pattern not adding all the cad IDs 236886 – Prima single arm machine has master/slave commands for some programs 237074 – Serialization error: No error occurred / the application crashes when shading the model 238118 - COPOPER select circle IJK cannot be edited. 238161 - Need Software Fence disable option to be able to calibrate stage 238181 - Extreme slowness during import and translation of IP file when using the UG DCI 238251 - Calibration XYZ - Need to calculate average error of multi-runs to minimize measuring uncertainty 238936 - Scanning: CAD Comp is OFF by default on programs migrated FROM: 3.5 -3.7MR1 TO: 3.7MR2/MR3 and 4.0, Results have probe comp errors on 3d analog scans (SP600/SP25) 238962 - Edit window never gets created with this program, application error when trying to execute without it 238978 – AutoCircle: Hang during create 239103 – Several labels are splitted between pages and the last one is partly off the last page of TextOnly 239119 – All vision circle features created using box select on cad view has the same feature name 239131 - improper tooltip and status bar prompt for Undo and Redo icons of the Layout Bar toolbar 239372 – AutoCornerPt: Incorrect path when surfaces aren't perpendicular 239599 – Mycrona Dual Z display not working in inch 239698 – Need to execute a COPOPER/EXPORT command to get the output, Apply does nothing 239714 – Vision probe offset processing corrupts the part program 239721 – Very unusual focus graph. 239758 – Several auto features are missing the Display Hits and Show Details options in summary mode. 239764 – The report dimension colors do not match the edit window colors 239792 – Sheffield controller with Tesa Star M auto Sphere out of memory error message 240126 – AutoRoundSlot: Laser: Array not large enough causing crash 240146 – AutoEdgePt: doesn't show thickness or edge thickness value in summary mode 240234 – Printing to an RTF file does not support append 240288 – boundary points for section scan don't stick to surface, but snap to edge instead 240353 - Customer is seeing two CAD models in the graphics display. It seems that it displays both ABS and WCS simultaneously. 240679 – Existing commands can't get grouped by automation 240781 – If a part program contains a load contact probe after a vision one, the contact probe is not animated on the cad during execution 240872 – AutoCone: dragging hits problem 240908 – Some problem with the list of the features in the FCF dialog box. 240946 – AutoRoundSlots: Can drag hits off the surface 241013 – AutoCircle: Single–Click selection of arcs, AngleVector causing problems 241112 - Toggling for constructed sets is broken 241193 - PCDMIS drives machine into the probe changer after CTRL-E the Load Probe of a vision probe 241210 – RunTime Debug – using uninitialized variable if you change illumination following a bad calibration 241313 – AutoLines: Void detection not working 241343 – AutoNotch: feature dialog: ‘0’ is missing as item in the combo boxes for the sample hits 241497 – Planar zone problems with FCF true position. 241506 – CAD detection within Find Nominals tolerance fails when no CAD is imported 241540 – Radial auto plane – the users can't select 1 as row number in the 'row' control of the probe toolbox 241704 – AutoSurfacePt: Copy/Paste, thickness value lost 241722 – Marking and block executing a constructed Cop offset point results in an empty pointcloud 241818 – Ctrl+E doen't work for COP and COPOPER commands 241898 - pcdmis constantly independently closes when the preview Window and Probe_readouts are open. 241904 – Add support for more than three cad element types for the autofeatures 241913 – Readouts window is defaulting to only having two fields on by default – Mag and Hits 241928 - TESA VISIO 300 Home position variance 241936 – Animated path lines disappear when the user executes the pp 241964 – With touch probe on TESAVISIO, collision error are not detected. 242192 - Vector Point or Surface Point with Cad using Find Noms and joysticking to learn feature finds incorrect nominal. 242449 - AutoRoundSlot: Void Detection of sample hits on round slot MLOPA2003_LDDB is incorrect 242510 – Can not create autofeatures with 1 click 242561 - Once a label template is created, all the subsequent changes cannot be updated unless the PC-DMIS application is closed. 242578 - There is a problem in the DCI after re-connecting to a model 242587 – Circle edge polarity backwards for vision tip offset cal with a sphere 242651 - Scan Filter and profile dimension problem 242690 – AutoNotch: Crash in best_fit_notch 242709 – Non calibration verify only run deletes the volcomp file 242751 - PCDMIS changes the touch probe when laser probe was used. 242759 – AutoSphere: isn't allowing edit of nominal diameter in command mode. 242822 - Auto Round Laser Slot is not measuring correctly. 242835 – Segmented Linear cal... Machine moves in Y when doing Xcal 242840 – AutoPlane: avoidance move functionality has changed from v4.1 to v4.2. 242865 - labels are displayed bigger with V3.7 than with in V 3.25 242894 - Graphical editing of pathlines has become much more difficult. 242929 - AutoCircle: Single Click - always selects stud at top, but also needs to select bottom when clicking near bottom 242974 – CADReportObject AutoZoom does not appear to work 243040 - Tolerances for datums not available in Advanced page of Line Profile 243051 - When changing tools from a TP2 to an LSPX3, there is no Prbtyp Nul command sent to the controller. 243083 – Profile 2d cad select in profile mode producing unusable targets 243088 - Selecting a different coordinate system after importing a model will reset all layers back to on 243117 – Autoshutter halo is off of roi if parcentral calibration is applied. 243174 - Stage Calibration does not consider the toggle "Limits enabled" 243175 - Verifying vision stage calibration without creating new cal 243196 – AutoEllipse: Can't toggle Cartesian/Polar in Summary mode. Works in V42b, but not V42r 243220 – AutoVectorPt & AutoSurfacePoint: ProbeComping in manual mode causes Theo/Meas mismatch 243236 – When the user cancels a collision detection all path lines and feature labels gets redrawn 243259 – AutoCone: theoretical length in summary mode doesn't carry to measured length, and other issues. 243294 - Laser Patch Scan path generation is not working properly. 243327 - CADReportObject not handling labels correctly 243331 – AutoMove available in EW, but not in PTB, when in Manual mode... that's an inconsistency... but what do we want? 243337 – AnglePoint: Created point with no sample hits 243364 – Focus Depth value on define ring gauge dialog is not remembered 243403 – Section cut Object is incorrect when it was applied on the duplicated page. 243415 – CMM-V at AB angles not allowing anchor points to be placed 243433 - wireframe and point are missed after change of the surface color 243444 - AFDlg vectors are normalizing when keying in values. 243447 - Tolerance display on the report is different from the specified tolerance. 243507 - Creating a runout FCF allows only the selection of a single datum. Customer has a callout with 2 datums. 243526 - Minus tols show Negitive is effecting True position 243537 - Multi-digit sample hits enter in reverse order. 243538 - Keyboard "End" causes feature execution with Probe Toolbox active. 243587 – AutoSquareSlot: Laser cannot be selected in CAD. 243588 – Laser Flush & Gap shifts off of the feature on every other execution. 243590 – PC-DMIS application error creating symmetry dimension on a cone. 243620 - Attached file can not be imported via Catia v5 translator in v4.1, Works fine in v3.7 243628 – Laser calibration with Perceptron and portable does not give accurate results. 243631 – The laser probe was loaded on the perceptron and then we switched to the 6MM ball and the software did not recognize the switch. 243666 – Using Feature Control Frame in the True Position dialog to enter plus and minus tolerance on a diameter is ignored when you build a FCF 243679 – Can't toggle the arm association of the second hit of a line 243687 – RMEAS/EDGEPT - RMEAS features are not being set 243702 – After saving program the True Position results are no longer valid 243723 – Stage calibration - Doesnt report max error corrected (BNS Method) 243724 – Switching between line or angle point and any other feature type cause incorrect surface vector 243735 – AutoLine: Line goes is created off of part 243786 – Edge Trace continuous run 243809 – AutoCircle: Can't drag hits, etc. 243827 – Pathlines disappears when the user toggle the feature type in the auto feature dialog 243866 – AutoCornerPt: Single-Click cad selection 243873 – AutoFeatures: FindHole setting is being changed during execution 243877 – Trying to save COPOPER commands back to 4.1 Release creates a serialization error 243884 – Patten holes create the wrong target coordinate of hole centers 243913 - AutoVectorPt: Point only mode - incorrect vector results in incorrect location 243936 – AutoNotch: does opposite of FindHole results 243975 - Trying to create surface profile FCF with datum at MMC which is a set of holes causes strange problems. 244039 – AutoCone: Stud - sample hits taken on opposite side of measurement hits 244044 – AutoLine: Difficult to be normal enough to drag depth, also casting issue 244046 – Delete Rows only reduces number of hits per row for some AutoFeatures 244060 - Opening the circle construction dialog with the Preview Window sets the Algorithm field to null. 244093 – Crash trying to use location for circle using Optical comparitor or gage hit target. 244108 - Cannot import attached CATIA DCT files , but DCI works fine 244132 – Print the report to RTF file problem 244146 - Vector Point Nominals are incorrect using the Catia ver 4 DCT 244160 – Feature ID from Adjust Filter dialog does not transfer to Edit Window 244190 – Lower Level Matrix not being created 244207 – AutoHighPoint: Rounding error (normalization) in Actual Thickness 244218 – AutoSurfacePt: AutoCornerPt: ACTL_THICKNESS not happening during execution 244262 – MOVE/CLEARPLANE is ignored when creating Auto Features. 244266 – AutoCornerPoint: AutoAnglePoint: 2nd (& 3rd) vectors have perfect measured data - impossible! 244295 – During loop, constructing a point at origin constructs at previous origin 244404 - Application error remeasuring features on an iterative alignment 244423 - Customer finds it diificult to grab the FCF in the graphics window for repositioning. 244451 – GroupCommand: App is crashing when pasting a group command 244470 - Only first page of screen captures are displayed on report 244486 – AutoSphere: Outside Avoidance Move crashes into part 244499 – Auto Feature TARG and MEAS values getting overwritten when F9 edit a feature that has vector with 6 decimal places 244571 - Cad by reference renders point entities as Giant golf balls 244576 – Execution of measured sphere causes application error 244630 - The tab order of AutoFeatures is inconsistent 244652 - Uninstall is deleting all *.dat files. 244714 – AutoPlane: overriding points doesn't work 244740 - Profile dimension not showing the feature id 244774 - Sample Hits=0 becomes non-zero INIT values in legacy versions 244778 – Paste with pattern for a lot of the auto features does not update the target values, just theos 244792 - Trying to insert this simple Legacy Report crashes PC-DMIS 244850 – AutoLine: THICKNESS_NONE not available in AF dialog, changes to THEO_THICKNESS when opened via F9 244906 - Program fails because variables are changed during saving 244910 - AutoEdgePts: no initial sample hits, even when registry "PTPSupportsSampleHitsInit" is on 244914 – CMM-V doesn't work correctly with touch probes and tool changers 244916 – Information in the CAD Assembly dialog and in Graphics window are not in sync 244956 - AutoSurfPt, AutoVectPt, AutoHighPt: In AFDlg, in polar mode, can't enter decimal values 244963 – COPOPER/IMPORT erases existing data from a COP object without prompting if the path is no longer valid or the file is no longer present there 244989 – COP Graphical Analysis is showing points for round Autofeatures being off by ball radius 245033 - Studs should turn on circular moves by default 245035 - AutoNotch: Rotated 90 degrees 245048 - Memory problem when adding laser surface points to pp 245083 - point AutoFeatures: feature created with ACTL <> THEO/TARG when "Show Path" turned off 245092 – Transparency for all dimension labels with 'NIL' background color 245167 – FindHole: Probe crashes into side of circle when using FindHoleType NOCENTER and samplehits 245234 - Feature ATCL and dimension MEAS are not in Sync 245318 – Vision RMeas defaulting to "Default" Mode causes problems 245333 – Midline Vectors flipping from 3.7 part program going into 4.1 245345 – PcDmis crash when save the file on arm1 245443 - Model transparency is not applied in the CadReportingObject 245474 - NO Z compensation beyond measured data zone 245478 – Manaul Mode doesn't work for Laser Surface Points 245485 – AutoCircle: Vision arcs at A90B90 coming out inverted 245533 – The auto moves of auto features are not executed in V37 in pps that have been created by a save as operation in V42 245540 – F9 on a construct feature originaly created using Tangent 2 lines but now been swapped to Tangent 3 lines and F9 change back to Tangent 2 lines results in PCDLRN.exe error 245559 - Deviation symbols 245585 - Cannot import Catia 4 cad model 245602 – No camera rotation or par cen warning for new probe 245654 – Round slots perform underscan when not required/requested. 245790 - Spline path does not generate the desired number of hits when the program is in inches. 245834 – Custom Report: ID.lbl leader line does not point to feature 245875 – GraphicalAnalysis.lbl does not clear after each use 245901 - Execution dialog opens during show path operation when a laser probe is used to measure features. 245905 – Auto feature toolbar greys out when the user changes the probe head orientation 245933 – ID.LBL can only handle features with 14 characters or less in the name 245969 – Modifying any Indent value in the EW will cause AutoMoveDistance to be updated to that value as well. 246000 – The ‘Show arrows’ option in the ‘CAD selection’ dialog is not working 246049 - AutoCone: incorrect move after height hit 246050 – AutoCylinder: incorrect AvoidanceMove 246096 - UV scan executes at the wrong position in Z 246174 – AutoCone: not calculating correct results on shallow angle & depth cones. 246198 – When a Tip is not found please collect them all together at the end of the part program with a comment proceeding indicating the problem. 246234 - Application Error when switching between the standard templates 246373 – Application error on execution after editing variable assignments. 246402 – Can't create any kind of feature when the grid lines are enabled 246439 – In vision feature using manual targets, the modified manual targets position are not saved. 246441 - UV scan path can't match the CAD model 246442 - change the "probe toolbox" values then I can't get hit when I take hit with Sheffield 246460 – Relative measurements move to wrong position 246470 – Long program path+name is over the limit (100 characters) for Siemens controller 246472 – Impossible to select label template from rules tree editor 246480 - True Position Feature Control Frames not giving Summary and Datum Shift 246482 – Part program get messed up during executing a script 246485 - closed scan doesn't close 246544 - The FORM command in summary mode is causing trouble. 246644 – Feature label is created twice when creating the cop object and a third time when applying a copoper to it 246656 – Problems importing FEAT/EDGEPT via DMIS 246666 – Needles are not reflecting Dimension Colors settings 246701 – Following Limit must be set to 2mm for X and Y during Homing to avoid any damages to the driving system 246714 – The crossing lines in the reports creates from a report template makes this kind of reporting unusable for Seat 246755 – Application error when specifying "Bring to Front" on report template objects. 246787 – AutoLine: Pathline jumps down (in depth direction) when using the Void button 246843 – Toggling angularity FCF's Use Projected Zone field causes a crash. 246870 – Application Error redrawing reports having more than one analysis object on the same page. 246878 - AutoLine: Hit Dragging problems 246886 – Legacy TextOnly report have any Dims Header bigger than page size 246917 – AutoPlane: angle vector not updated selecting different planes 246918 - AutoPlane: wrong vector for hits 246933 – Nominals and Dev are wrong for TP 246950 – Large Z move after canceling Read Position dialog 247014 – The label color for the audi_point label is incorrect. The color of the label is not in sync with the value of the deviation. 247033 - Update work offset in NCi does not allow for changing base alignment 247034 - Fanuc axes map is not correct if Transform is selected in Update Work Offset 247038 - AutoPlane: Can't delete individual user-defined hits 247107 – Offline DCC mode doesn't work (Metronics) 247119 - IGES Import non functional/IGES ALT very slow w/ Large cad file 247121 – Profile 2d feature only lets you click two points to define 247135 – THEO start and end angles swap randomly when executing a vision circle in a loop with an offset 247143 – AutoCone: Avoidance move after is wrong. 247148 – RTF files are messed up – CAD image is missing 247204 - True position summary table results non consistent when tp is on multiple features. 247217 - Modify feature nominal and answer Yes to "update related dimensions" does not update FCF feature nominals. 247254 - PCDMIS is excruciatingly slow when editing FCF commands 247275 – Calling by automation PartProgram.Close() or PartPrograms.CloseAll will make PC-DMIS crash. 247296 - Laser AutoCircles are created Out by default 247328 - Specific Alignment / Position issue from v3.7 into v4.2 247369 – Graphical point selection not working properly. 247375 - With tertiary circle datum (measured circle), datum constraining is not working. Get erroneous tp results. 247376 - Laser Patch Scan only generate a single path and does not increment to the return path. 247378 - AutoEdge: ‘Save as 37’ operation adds an ACTL THICKNESS to the auto edge points - pps serialized from V42 to V37 can not get executed 247386 - Error of synchronization in the iterative alignment with double arm 247400 - It is impossible to insert 2 consecutive Linear Open laser scans with the Metris sensor. 247441 - On fcf advanced tab for tp, change output alignment then Cancel and dimension nominals are out of sync. 247466 - AutoSlots: Single-Click cad selection not working for this cad 247476 - Unable to calibrate ACR3 247488 - CADSelection: We are still not able to select edge points in V42R like we are able to do it in V37 and V42B 247506 - AutoCircle: Laser diameter is 0 after cad-selection 247518 - Changing label template for a label that includes mods crashes PC-DMIS 247601 - Printing or saving a report (pdf/rtf ) which includes a screen capture crashes software. 247622 - Profile 2D autofeature (vision) : Impossible to measure this profile, the detection target not follow the CAD file 247748 - Changing pixel locator type to FIXED THESHOLD always changes the TRESHOLD value to 40. 247765 - CADSelection: another auto slot they can't click select. 247783 - The latest Release Candidate has an 'Invalid Threshold' message 247785 - An invalid argument was encountered with IP Translator 247828 - Larger files take excessive time to load 247847 - Serialization error on all Laser features opening this 4.1 program after converting it to 4.2 248689 - PC-DMIS crashes when trying to display a report with lkdriver.dll loaded. 248763 - STEP file comes in but cylinder surfaces can not be used to create features 245284 - Concentricity to a datum circle should be a 2D calculation (don't level to datum circle) ----------------------------------------------------------------------------------------------- Version 4.2 Maintenance Release 1 (Additions After May 10, 2007) 225154 - Selecting the feature TEXT from the CAD window does not select in the FCF. 240685 - DMIS imported AutoRoundSlot cannot be measured, bad THEO values 241006 - Crash during Ring-Light calibration 242529 - Angularity dimension for a plane displays unspecified projected tolerance zone in report label. 243428 - Illumination set warning when using subroutine call 244029 - AutoLine: difficult to change length field in dialog 245116 - Point Clouds executed on Arm2 are not being drawn in the correct coordinates. 245283 - Parfocality : with high calibration, for each step, the first focus use auto illumination, and not the other and the circle measurement 245445 - Auto Focus in release build crashes 246367 - AutoPlane: User-Defined Hits after we've moved the part, Avoidance movement doesn't work correctly 247106 - Use CAD provided ID's for Feasture 247184 - Unmarked Hyper-report commands are marked when reopening the pp. 247260 - Old version of PCDShellextension.dll installed 247301 - myhasp.dll needs to be copied to the perceptron directory to successfully load contour.dll 247571 - 2D Profile does not show hit targets after first click 247637 - AutoEdgePt: with 0 sample hits on the hexblock. The depth is 2. When I execute the feature the hit is measured at a depth of 0. 247641 - After the alignment translation hits path is out of the Cad model 247724 - The same point have diferent meas. results 247817 - Autocircle Avoidance moves have fixed (large) distance 247822 - Outside Cylinders using negative spacers and Avoidance Moves can cause the probe to crash 247873 - AutoPlane - Laser - Target XYZ location changes when back saving to 4.1 247889 - Auto Feature: the master and Find Noms was confused ( Chinese and English are same) 247920 - Convert a 3.7MR3 Hyperreport with Analysis Window to Customize Report doesn ´t work 247928 - ‘Distance to closest CAD’ overrides ‘Distance to target’ during execution, making ‘Distance to target’ useless. 247939 - After converting their hyper-reports to custom reports the part program executes 1min and 15 sec longer then before. 247941 - When they convert their HRs to CRs the former variables and input comments parameters are not converted to the CR 247955 - Auto insert moves is not working with Heidenhain probes 247981 - Lower tier of composite true position shows large deviations 247999 - PC-DMIS hangs when opening report window on large report 248017 - Measured results are modified each time I F9 on an FCF Position 248042 - Always the whole CAD assembly is visible in the CAD images of the report window 248097 - Error programs sfera85. prg resulted of the sphere non congruent 248107 - The customizations on the tag items in the section cut settings dialog and the resulting image in the report window are out of sync 248207 - ltvideo2.ocx needs to be included in the install set and registered in the application directory. 248262 - hyper report rpt files are distroyed after using the v4.2 248292 - The PDF file doesn't show the correct dimension color 248335 - Template reporting is screen resolution dependent and unusable for them therefore. 248354 - pp with big amount of dimension failed 248367 - AutoCircle - CCW CW combo is blank 248376 - Possible vector problem when RMeas feature has sample hits 248389 - AutoCircle: Studs with > 1 sample hits (with no avoidance moves): Errant circular move causing machine to drive off into space 248403 - Manual Laser scan, with multiple segments, looses data when done button is pressed 248419 - There are some unknown characters when I print the reporting to rtf file 248446 - when I create a new FCF True Position in mm it shows the True position way out, again it looks like it's multiplying the mm dim. by 25.4 to come up with the location. 248459 - Target folder for converted hyper reports 248468 - I get an error indicating "CAD file could not be read. An attempt was made to access an unnamed file past 248479 - AutoRoundSlot's angle vector is being solved 90 degrees to what it should be. 248487 - Application is crashing when deleting commands 248496 - AutoCylinder: Z value is incorporating Length in Dimension 248521 - They can't place fixtures with more than 12 columns 248544 - AutoVectorPt: Snap Problem as reported by James Mannes on user forum 248557 - Change view in analyse Window object crash PC-DMIS 248561 - Print command will not print to PDF and report contains all zeros 248568 - DMIS dual arm pp doesn’t not import correctly. All commands are assigned to Arm1. 248652 - Path optimization sorts the features even when this option is switched off explicitly 248678 - Can't pick points on the cloud 248684 - The optimize path operation doesn’t flip the feature vectors - probe tip errors are the result 248716 - AutoCircle/Cylinder BestFit Math Type not brought in from Legacy programs 248728 - Regardless of new CCW option, starting and ending angles are getting made 0..360 which causes problems 248760 - Inch Units Operation hasa hugh Offsets 248839 - Midplane construction produces undesired plane 248860 - need to hook generic parser to ip measure, not ip planner its end. 248870 - SAVE/ALIGNMENT,ML_PCS,ML_PCS.ALN,MACHINETOPARTS is missing after the Import 249033 - Report Window does not update as dimension commands are executed 249037 - Auto-Sphere doesn't produce the correct diameter, when the hits are manually measured. 249088 - Report Window ... for a productive use this is not usable. 249097 - FOV Cal focus range incorrect 249099 - App is crashing when converting a HR to a custom report 249106 - Measurement target area larger than FOV when measuring manual circle bigger than FOV - On Manual Machine 249137 - Crash when I try to convert a hyper to custom form 249140 - Can not close a report converted from a legacy report 249142 - The reporting permanently causes the computers to hang 249171 - Problems when working with template ‘audi_a4_2a_pw.rtp’ 249197 - T-Deviation is incorrect for features with ACTL thickness 249221 - Unable to perform perimeter scan on part 249237 - The form is always empty ,after i opened an exist form or create a new form 249258 - The overwrite and append options forces an index onto the filename. 249264 - Scans do not have Defined Execution Mode or Boundary Points 249265 - Status window display has changed - line is missing 249300 - Serialization errors related to several scan features 249337 - App is crashing when deleting CAD elements 249361 - COP points are not deleted when the corresponding scan command is re-executed on arm2. 249377 - Bestfit with scan 249382 - The Measured Square slot in QS seems to be broken, it is very unpredictable 249387 - Collision detection freezes half way through the process and hangs indefintely 249418 - PC-DMIS hangs when using a Dtype in the text expression field in the Edit Rule dialog 249439 - Importing a CATPart causes PC-DMIS to Crash 249444 - Probe Readout will not update on PC-DMIS startup without some help 249509 - Crash when reading optical calibration cert file 249521 - Redraw the Report does not work correctly when template includes VARIABLE statement 249541 - Angle evaluation is incompatible with older versions - signs of evaluations change 249550 - Mirrored part programs are not adjusting the AutoCircle Start/End Angles as expected causing machine crashes 249553 - Clicking on targets in probe toolbox changes to the correct illumination, but clicking in the live view doesn't. 249557 - Section Cut profile is missing in the PDF file 249608 - When inserting text with audi_text.lbl the length is limited 249615 - CurPage and NumPages are not working in reporting scripting language 249639 - DoNotUse AmyuniRTF=1 causing color change in Report Window 249648 - Surface selection seems to be random in the UG DCI. 249712 - Multi-page report with Section Cut displays "No Image" 249715 - Progress bar during import of a STEP file 249724 - After pressing cancel in the dialog now a cut section object appears in the report. 249815 - Unable to register DLL: Dim Analysis Activex.ocx LoadLibrary failed. 249894 - STEP imported models are not correct 249963 - VIEWSET functions were never properly implemented 248012 - label count can't increase continuously 248874 - RMeas Their V37 pps does not execute in V42 - features gets measured in space Rmeas 249229 - Auto/Circle with the read position option turned flips the Yaxis to negative Y when you save it as the new target during program execution. 249552 - Pattern two features the labels don't work correctly 249397 - Higher quality cad printout makes 4.2 pdf output large 249190 - Application error occurs during program execution when external video object is set to Print. 248025 - IP translator does not correctly set the IPD defined spacer for auto square slots 249165 - Collect program on Siemens consumes memory when running in NC mode ----------------------------------------------------------------------------------------------- Version 4.2 Maintenance Release 2 (Additions After September 4, 2007) 248881 - 2d Profile target not being drawn correctly on CAD when in inches 250005 - When Focus fails, PCDMIS drives the machine to 0, 0, 0 without asking -> crash 248700 - AutoFeature Report Vector - TRACONSA 250420 - Line can't pierce the curve to generate the point 250488 - Gap Only not functioning correctly 250605 - Blank Cad bitmaps are randomly generated when MS Office Clipboard is active 250600 - Picking points on a pointcloud is not working correctly 248998 - Calibrate Probe Offset : Fail to set top illumination for measuring surface points 250092 - Auto-Focus Failure : Z axis is sometimes moving up out of focus when measuring feature with auto-focus 250774 - New Best-Fit alignments 250799 - Square Slot measurement process has changed from 3.7 MR3 causing machine crashes. 250390 - Arcs created in PC-DMIS V4.1 are displayed as Circles when the part program is opened in PC-DMIS V4.2MR1 250459 - Cancelling the vision probe tip offset and saying to keep partial data creates extremely large tool focus offset 250350 - Draging points inside auto feature will move vectors witch results in crashing your probe 250832 - Legacy part programs with AutoCylinder Studs are not executing in the same manner coming into 4.2 causing a physical crash 250205 - When XY std is elevated, XY verification has Z drift and fails 249599 - Simple switch between solid and wireframe view. 249773 - On Page 2 of the report the labels don’t carry the index of the execution (should be 2) - Verification of 249169 249948 - The termination of the leader lines does not correctly auto scales the label to the content inside the label. 250818 - After reopening the pp whenever we switch to the report window the application is crashing. 250472 - Auto Circle: Pitch is not working correct 250423 - Edge vector in Edge Point mishandling thickness offsets 250927 - Composite true position FCF allows different datums on lower segment than on upper segment 250718 - Collision detection failes if we use a theo thickness 250937 - No Moves are added if we don't check the 'Delete existing moves' check box 250824 - They can't use the offline created reports on the online machines - they open messy 247480 - Probe PH6 head has an offset problem when configured with CMMV 251062 - Serialization error for each command in program followed by program hanging on open 250408 - Multi box selecting with CRTL key is broken 251149 - Pressing 'Print' on joystick doesn't enter a tip command to the pp. 249789 - new Probe Readouts hits counter does not update during execution, shows "0/3" for each hit. 251129 - The leader line does not go with label 250411 - Thickness fields not functioning correctly 250735 - At Origin point not constructing at the origin in a loop 250809 - Installer for V42MR2RC is causing trouble 251017 - COP Oper Select and Section commands change XYZIJK values when a new alignment is performed. 251052 - Software Crash when Measuring a Sqr Slot with Find Hole enabled in Manual Mode 249112 - This is not working on real parts. It seems that the arm2 ignores the fixture completely. 249814 - Report shows red numbers but green bar 251200 - Leaderlines are missing in the AUDI reporting 251289 - Surfaces are missing after the V5 DCT import 251409 - It is impossible to select a point in the cloud when trying to do a cloud alignment 251260 - ACTL square slot length is wrong (up to 2mm) and somehow linked to the corner radius 251057 - Probe path for stud slots is wrong 249419 - Labels blurry when made smaller 248129 - Autofocus for edge point does not give smooth graph 248530 - Need access to Faro Utilities during pp execution 251168 - Mycrona new Controller needs new HSI installing 251147 - Probe Tips is lost in double arm mode 250833 - IP measure is not working on their part (simple prismatic) 251067 - Box selecting vector points from DES data does not use CAD Provided IDs 251357 - Mycrona reporting that fixed lens calibration in V4.2 MR2 RC is asking to zoom to highest mag 251266 - Problem with surface points measured relative to another point. 251250 - Section cut is not visible in the part image of the report. 251036 - Point info not supported in Custom Report 251227 - CncSerialFile data collector utility does not run without Windows MFC dll's installed on XP clean pc's 251262 - The defined Prehit distance value from the pp command auto changes during execution after the measurement of round slots 250771 - Get message "Error 5" when selecting Auto-Feature 242264 - Problems with vision features when the rotary table is set to 90 degrees 251336 - Touchprobe stays turned off after aborting a tool change 245511 - Cone to cylinder runout suspicious 244649 - Distances show in summary mode under settings wrong reference Id's 251492 - Extended Sheet Metal Option: Use PIN 251771 - "Not enough information to construct circle" message comes up way too often and is annoying 251174 - Add support for R18 in the CATIA 5 DCI 247886 - Attempt to move motion during Focus, locks up PCDmis software. 243768 - CncMDI: Skinning Failure when starting CncServer.exe from a shell command 248832 - MYCRONA: PCDMIS moves the machine to a position wrong about the tip offset 251813 - Surface vector on edge points are not mirrored 249400 - Only Arm 1 runs when executing dual arm program. 248647 - TESA: If the contact probe stay opened (probe problem), the machine don't stop, try to measure the part and break the stylus. 250938 - Several errors using the original report templates 243539 - Some edit boxes in the probe toolbox require 2 and only 2 digits after the decimal. 251359 - Instructed to "Please focus on slide" but it's rather unhelpfully turned the lights off for us. 251616 - Edit Custom Report will only work if the report window is not being viewed. 248984 - TESA: DCC Homing : Backward speed sometimes switched to nominal speed causing FollowingError 251632 - Create auto feature need to press "End" button twice 250730 - Pcdmis CAD, Linear Open Scan CAD control is greyed out 250948 - Problem with rtf print in standard template after several pages 251862 - Auto polygon selection is not working on the 3 sided slot of the DMIS capability part 251854 - Focus Z result not showing on toolbox, it's gone onto second row but you can't scroll down to see it 251907 - Measuring a Surface Point in manual mode is letting you position the measurement, then it does a DCC move to the theo position 251890 - Reports Touch Trigger Probe is active on Live View when you have the Mycrona laser probe active 251934 - InFOV check not working with rotary table meaning it does move for all 248219 - Perceptron calibration with low accuracy 251724 - When I load the machine profile the probe orientation in the graphics window does not update 251821 - FOV cal focusing not working correctly. 243185 - AF Swapping probe types has crash in EW 251895 - After FOV pixel size calibration, motion via track ball is no longer work. 251828 - Slot Math failed, point on the first edge are too close together. 251922 - Crash after open MoveTo dialog box. 251829 - The collision detection dialog is broken. 252210 - The page magnification in the report window has no effect 252184 - TESA: Missing Laser Toggle ON/OFF in Probe Toolbox 252173 - They can't execute their V37MRS pps that uses RMEAS in V42R 252110 - Untrimmed CAD surfaces when they open their V37 pps in V42 - makes V42 unusable 252128 - Auto polygon selection is not working for the 3 sided polygons (inner/outer) on the polygon capability part 251345 - Calibrate Active Tip behaves differently when executed in main program vs within subroutine. 251954 - Mycrona libraries crash PC-DMIS when they try to shut it down 252038 - WLS doesn't work with Laser Probe toggle button 251765 - TESA: Calibrate Illumination : Ring light not automatically switched off when starting calibration of Coax light and vice versa 252003 - Cad Assembly not shown in Inch program 251900 - Machine Types incomplete on Mycrona and no mention of Optiv 251899 - Add Mycrona Library Version into Machine Interface Setup Dialog 250040 - Heidenhain Work offset update does not properly adjust rotary table 249438 - First hit is not accepted because Station #3 is active, instead of being reset to Station #1 251522 - Message "Do you want to update nominal of related dimensions" is missing 251990 - When they select the CRO on a duplicated page the CRO on the original page gets the focus 251404 - AutoFeature Cylinder Number of Hits Keep Changing Back to 3 248352 - AutoFeature issues when using a Pin Nest 245526 - TESA: XY Calibration : 2D distortion patterns and Y straightness issue 251933 - Live View VCR buttons don't work with rotary table 251240 - Their machine is moving when they partially execute commands from cursor. In the commands below the cursor there is no move command. 252158 - Application is crashing when closing the part program 250275 - Auto Insert Moves on a probe build with Tesa components results in a lot of collisions. 249085 - Lower tier FCF profile doesn't verify datums when "form only" selected 249241 - When they SaveAs their pps from V42 to V37 the CAD model and the pp features are out of sync 249933 - PCDMIS can't get the correct nominals from these CAD Auto Cones 252037 - When they create a custom report and add a CRO it alway shows the part in 'Solid' - This is not use able for them 252371 - Machines w/ Analog probe that does not return deflections the Zeiss algorith is not used 252555 - Exported nominal features do not all match UG prt file in Unigraphics 252150 - The label modifications are not consistent - a black cell appears in the label 252066 - We need to add support for the calculation of the shank tips based on the measured Tips 251802 - Reports fail ....text is scrambled ,,,PDF, RTF,printer, etc,,, 251577 - Polar coordinates does not produce the correct vector 252615 - TESA: RingLight flashing on and off when sliding cursor in Probe Toolbox 249338 - Cut profile object is not accurate enough 252688 - When we duplicate page, labels will be shown disorderly 248726 - MYCRONA: PCDMIS crashes during cross probe calibration with vision probe 243641 - Straightness always shows deviations for vision features on one side or the other, looks strange 252690 - The application is crashing when removing the location modification in a different magnification 252423 - We found a problem in the reporting with the dimension colors for the features. Always if the deviation is at the limits 2 colors are used 252427 - The label modifications are not consistent. Reporting is not usable in the moment for this reason - Blurry labels when making the ID row visible 252420 - Report commands with multiple lines do not write DMIS conform TEXT/OUTFIL statements to a DMO file during pp execution. STATISTIK rejects these DMO files 252471 - Wrong report presentation in report window not matching the report template 252488 - If Marking sets closed about button Filemanager, PCDMIS crashes 252451 - CornerPoint: measurement results are unusable, strange vectors displayed during execution 251287 - A value of 5000000 is set in the registry but the virtual machine is still much too slow 251993 - The grid object based labels have an incorrect column order (in the report window) 250007 - Auto Circle created in 4.1 with negative start angle and negative end angle opens in 4.2 with rotation at CCW 252650 - When duplicate page, label mod around column will be lost 252316 - The information in setup print report dialog are out of sync 252369 - User defined IPD values for distance move on an auto slot are not respected 252383 - When I open the AUDI pps in the current build (21.12.07) the labels for the points in the report window are empty 252600 - Application is crashing in the mirror operation 252573 - During the execution the auto circles becomes broken 252355 - Many features which do not have an output in the pcdmis have output in a dmo-file. Results in dmo error 251582 - During a refresh operation in the report window the customization on the section cut profile gets lost 252574 - In French, Problem creating an autofeature, since Pcdmis adds a space ! and some times not ! 251752 - Reporting Expression =VARIABLE("BD", "TROCKENLAUF") returns incorrect results 252903 - Closing the Setup dialog with button ==> Error message pop up 252751 - X-Axis letter is missing on the label - The DEVATION is displayed instead (in the wrong column) 252763 - Axis column should be visible again after all object modifications have been removed 252093 - At each IF condition there are pp stops and delays for about 10 seconds 251888 - Opening certain programs crashes PCDMIS on some computers, but not others 249602 - Calculation times extremely long 251865 - RMEAS problems with 2 holes 252808 - In the report and in status window the dimensions of the attached part program do not appear in execution order 252861 - Each selection of the CRO followed by a refresh in the report window is shifting the image in the CRO 252832 - Each refresh in the report window changes the scale and the view to the part in the CRO. In most cases it is not visible any longer 252436 - Resizing CAD Reporting objects with PC-DMIS auto scale to fit which damages their reports 252453 - Loading the report window causes the part to change. The modified label is not visible in the current view. 253122 - Changing the probe head oreintation in the F5 dialog has no effect on the virtual machine 243408 - Several TRUE and FALSE statements red in the EW, no way to execute after importing this Tutor program 250032 - Feature measurement reapeatability is poor with moderate or high approach speeds 246777 - When change Arc angle, assertion occurs 252999 - Hiding a label is deleting the leader lines on other labels on the page 253025 - Min Circumscribed cylinder coming up with incorrect values for cylinder constructed from measured points 252975 - Fixed columns do not work 253139 - The probe toolbox is delaying a refresh of the report window by 20 times 253097 - DMO printing outputs only THEO values and not measured 252923 - Mirroring a part to a reference part (using the existing QF alignment) is not working 253055 - Information in the label dialog and the report window are out of sync 253241 - Section cut profile on any of the duplicated pages - It should be only on the first page 252929 - Importing a oldstyle hyperreport to custom report all the leader lines are pointing to the top left corner of the page 253196 - Application error when loading an existing default report (in the refresh operation) 253174 - Resizing lines targets don't work with rotary table 251369 - PC-DMIS crashing when trying to insert an AF Sphere into part program 252907 - PDF Document did not show the same view as in the report window 252860 - A duplicable dreaded serialization ALT. CNC Specific 252572 - Feature in polar coordinates don't get correct nominals in FCF Advanced tab 252836 - Impossible to set dimension colors to 1 level with three colors 252736 - Using CANCEL in the AF dialog is mismatching the RMEAS features 252283 - Probefile for Arm2 working in dual arm becames too big 251594 - The probe head crashed into the part during part program execution 249603 - Unable to run arm2 in attached part program 253106 - An leader line without a label connected when they rename the dimension ID 250987 - Points default to green on the graphics screen 253352 - DMO output file with few measured values missing 252990 - They can't copy and paste commands from one place to another... 'Highlighted object(s) may not be cut!' message 253432 - Grid Lines are not showing up on the report window 253361 - Table angles reported incorrectly to journal file 253402 - Wrong message inserting dimensions 249779 - PointTo command ignores Station Move and points to the wrong position 252045 - Method to count the nurmber of visible or active rows on a label that has been edited on the report window 253415 - Importing STEP file in INCH crashes when drawing surfaces 253546 - Probe file , Viewset and some menu options are sluggish 251816 - Trigger plane inch / metric problem 252465 - Elements imported from CATPARTS don´t get the correct name 251902 - CMM-V not compatible with Toolchanger 253444 - EStop during tool change leaves probe disabled 253498 - Customization of Labels in 4.2 MR2RC don´t work like in MR1. So, it is not usable for customer 246451 - Invalid VCP Runs counter to “authorize” the opticstagecalibration.exe 246139 - V5 Catproduct assembly doesn't import correctly as compared to the v5 dci 245529 - Stage calibration Z verification measurements are incorrect 253536 - Application Error when deserializing the V37 pp in V42 in the ‚Generating Surfaces' process 253694 - Doesn't pick up CMM-V on TESASTAR-R toolchanger 246298 - CRO: Label Layout Wizard: Enable Manual Sizing checkbox auto unckecks 253369 - CRO in Custom Report is not retaining profile dimension settings 253740 - Printed report does not match the report window for parallelism dimension. 246093 - Population of label properties to other labels is not working (part of PR #246440) 245999 - cad mods are not printed 251381 - PDF-Printing from CAd REPORT shows wrong origin 252300 - MYCRONA: Wrist doesn't work in MR2 but was ok in R 253248 - MYCRONA: PCDMIS drives probe into tool changer 246060 - Can't switch on Rotation Cal on CMM-V (or any fixed lens system) 249561 - Textual analysis missing in the PDF report, there's only a ( light green? ) invisible background 253287 - Application error during the pp execution 252421 - Application is crashing during DMIS Import 251471 - 35mm disk calibration problem 251636 - 2D profile in Inch randomly driving machine 252829 - Surface Points with polar coordinates is changing the theos when he executes the program offline 253392 - The attached pp crashes at execution time when generating the report 253455 - Importing a HR to Custom Report, the final result is very different than original report. 253664 - Many application errors suring execution, either at the start or at conclusion 253754 - TESA: Visio300 : Pendand FineSpeed not correctly set 253492 - when using F5 part machine / part setup not possible to program 253962 - v37 UG DCI program can not be import into v42 correctly 253571 - Application crashes when setting view plane when in ONLINE mode with activate Part Alignment. 254115 - autoswitched USE SCALING to "ON" in 2D- bestfit alignment with non- uniform displaying in edit window and aligm-window after load V42MR1 PP in V42MR2 -> crash 238675 - cad window is change the displayed resolution (The actual problem here is activation / edit of CRO on custom report editor for the converted V37 hyper report) 254184 - Total bonus on legacy TP seems too large 247728 - F9ing BF alignment turns on scaling 247009 - FCF TP can't allow to key in positive lower tolerance 253280 - MYCRONA: Can't switch off rotary table 254315 - The quick fixture alignment tools create an 'illegal alignment' where both, the CAD X axis and the CAD Y axis are equals to the Y+ machine axis 248997 - Generic Export is missing several features from the part program 249917 - Calibration warning of 1 day or 1 hour etc. is not working 249616 - The SolidWorks DCI does not appear to be converting units for Findnoms Tolerance 254160 - In V42 they can't click select their square slots any longer 254198 - Crash opening readouts ( Ctrl-W ) on arm2 249654 - there is an interrupt problem during the line scan 247472 - More reflector offset problems if measuring against CAD surfaces 250914 - COP Oper Select and COP Oper Section are not returning correct XYZ values when mouse clicking in ISO view of graphics window 249997 - Probe Readout : Target Position not correctly refreshed 250913 - COP Oper Select and COP Oper Section do not change XYZ IJK values when a Pattern Offset is done 250912 - Auto feature circle or vector point crashes pcdmis after execution 254461 - Scripting errors with a converted hyper report 252034 - Very long delay after measuring a hole pattern 254014 - TP values are wrong when I use hole pattern function 254304 - Error in Best Fit Recomp algorithm in constructed planes 249919 - graphical analyse of roundness is turned over about 180° 251277 - Report looks ok in the part program no features missing but when you print this to a file a few things are missing 254538 - Problem displaying Custom report command in edit window 249249 - Axis Vector not reported by the Status Window, Report Window is fine 254660 - PC-DMIS crashes when constructing a line from scan data 254637 - After delete "Bundle Alignment" rule tree in "Alignments", when delete "Bundle Align" in "Parameters", pc-dmis will crash. 250642 - Slot measure in the procedure 254588 - TESA: French : InitString: Unable to load string "IDS_TV_DTYPE_EMBEDDED_REPORT" 250488 - Gap Only not functioning correctly 250788 - Can't open 3-2-1 Alignment Wizard - pressing on the wizard toolbar icon brings up the exporttoexcel application. 254582 - Multi click selection on round slot is broken 254429 - VDA Import is broken 247863 - Best fit constraint giving different results than Bestfit 2D with equivalent parameters 249973 - wrong recalculating of nominals when use thickness 250186 - DRO and probe buttons of LK-direct interface won´t attach permanently in toolbar 254774 - After executing PP in Operator modus all comments and headlines are missing in the command mode..this pp are broken 254478 - German Mirror Dialog is broken again 253030 - User Assigned Properties Doesn't work if report window is hidden 246304 - Multiple probe files can only display animated path of the last probe file 250720 - Printer button of the report window toolbar won't work till you select options Report Print Options dialog 254778 - Size of CAD files is causing troubles 254815 - Prob3: Trihedron to small in printed pdf, but looks ok in the Report Window 253926 - the nummering of the page sites are incorrect 254210 - Editing of objects on custom report doesn't work 254388 - Single click on round slot returns wrong slot nominals 254727 - the Tracker Status bar is missing 254726 - five Tracker Operations items no longer function in v4.2R 253872 - Section scan crashes if Density is too small dialog is shown 253677 - PDF file and Report window are out of sync 254939 - Compatibility issues with part programs created in version 3.25MR3 254938 - CAD data are destroyed after opening the pp in Version 4.2 MR2 RC 246415 - Reporting is crashing 253223 - auto calibrate probe statements in program cause crash 251490 - Pagebreak change after each click on the refresh button 252405 - PCD2Excel is not exporting profile dimensions 252900 - Cross Probe Calibrating on the Ring gage should NOT chnage the diameter of the Probe tip 253007 - point vectors flip to wrong direction when I add the external alignment 253248 - MYCRONA: PCDMIS drives probe into tool changer 254116 - Tolerance Zone of Analysis view in Customreport is shown wrong 254860 - Actualization from Variables in Gridcontrolobject doesn't work 254933 - Find nearest CAD element error 254988 - Single click on round slot returns wrong slot nominals 244604 - GD&T not converted correctly from Catia cad model to PC-DMIS Feature Control Frame 255231 - A PP with a lot of Features is loading 12 times longer like in 3.7, because all hidden ID's are load in the beginning and then hidden 255110 - Refresh of the report window takes 11 mins 254246 - FCF report shows negative bonus on tertiary datum 254300 - TESA: Visio 500 is experiencing following errors during homing 254354 - The image of the part is missing on any page of the PDF file 252597 - Unable to release PCDLRN 4.2MR1 process by VB6 application. Same application don't have any problem with PCD3.7 MR3 255298 - On some pages the scale to the view on the CRO in their reports is different as in the previous version (timestamp 11.02.) 255311 - Script execution changes the active alignment 252732 - Leader lines in custom reports do not move with the labels. 255253 - Daimler Wörth - PCDMIS crashes, if I open a pp with cad file 255173 - Labels on duplicate pages got lost when they are not visible on the original page. 254369 - Saving a V4.2MR2 (c) program back to the V4.1 format causes a problem with the CAD file. 255471 - import IGES file mistake 252199 - MYCRONA: Crash when I change folder in the file open/save/import/export/mirror etc dialogs 249688 - Changed not the PR NOM and PA NOM in X NOM and Y NOM when you switch from Polar to Rect in the Measured Circle 255455 - the Cad file display problem when V35mr2 CAD file load into v42mr2 253860 - Printing at end of subroutines cause PC-DMIS to crash 255249 - pc-dmis hang during the offline collision detction 249758 - Gage block display wrong data when print to pdf 252552 - When editing X-act TP for the second time ap crashes 252901 - The attached DMI-files crash PC-DMIS without any indication of what's wrong 252821 - DMIS RMEAS/LEGACY creates problem when SHEETMETAL options is disabled in portlock 249305 - Leader Line Termination is incorrect if Nominal selected but Use feature centroid is not selected 255587 - SP25 Probe sometimes does not arm before taking the first manual point during program execution which causes the probe to drive into the part until the wrist disengages, thus damaging the probe or stylus. 255470 - dimensions info on Cad window can't display the correct decimals when I open the existed pp 249011 - concentricity calculated the wrong value 255274 - some temporary trash files generated when open pc-dmis 255784 - pc-dmis crash during Hyper report editing 255790 - Importing a HR to a custom report, leaderlines get disconneted to the labels 255792 - Changing label template in custom report, PCDMIS asks two times for the label and leader line gets disconnected to label 255654 - True position has extra "DF" tolerance 254912 - Creating a dimminfo command doing double click on ID lablel in graphic screen it can be inserted above the feature command 254852 - True Position (legacy) deviation is inexplicably high 256121 - Software crash if we open the CAD Only report 256304 - Empty pages between the hyper reports in the PDF file 256398 - It's not possible to shift the CRO any longer 255897 - There isn't PC-DMIS property on legacy report (hyper report) 256005 - Image of the part is missing on some of the CROs 256112 - Error in "Find nearest CAD element" function 247423 - Executing a program after changing a point's hit count from 0 to 1 causes an application error 252735 - Application Error when saving the pp after a refresh in the report window 254853 - "find nearest cad element" function returns wrong nominals while programming auto vector points on imported customers 256319 - all path lines will change to red color if there is one feature has collided during the collision detection 253150 - After 2D-Bestfit PC-DMIS switch automaticly the Scale Factor 252476 - Only first page of the PDF has the correct size 252264 - Cannot draw a solid line on CAD in reporting window 245576 - Constrained best fit not working 252216 - When installing PC-DMIS Portable with PRO programmed on my Portlock I cannot get Portable Toolbars to install or work with Tracker! 247174 - Perimeter scan on a single surface, getting wrong surface vector half way through scan, some points good, some bad 251757 - global_part_program_active printing problem 254661 - Follow up to Problem Report # 259641 Symmetry dimensional report and Problem Report # 254662 255180 - TESA: Parfocality calibration error 255342 - The indexed file (introduced in V42 and up) does not work correctly with inline hyper reports. It will generate a new output file for each one. 255343 - inline hyper report flag not handled correctly when deserializing 255463 - Can't take the same point on the Cad 255467 - After collision detection pc-dmis can't identify and display the collided path 255823 - what is the error message E from VBS mini editor ? 256428 - rotary scan doesn't support variable as the radius 256563 - circle scan/cylinder scan don't support variables correctly 256689 - Changing colour ball size or status (enabled or disabled) all the labels moves by itself in custom report 256940 - DCC hits commands will generate - Invalid command/Invalid Parameter Error messages 256868 - move clearplane command can have incorrect path line color 255858 - There is the regardless option add into excel sheet when I use pcd2excel 257048 - Cannot edit THEO values for AutoFeatures 256114 - Bonus and Deviation are not being calculated correctly on Legacy True Position 256556 - pcdmis crash and pp destroyed 256712 - When we import an IP file the report vector is not in SYNC with the surface vector (it seems to be hard coded to 0, 0, 1) 246140 - Custom reports mess up rtf output 247662 - Label properties and information in the label propertied dialog (IDD_HYPER_GRID_LABELS_DLG) are out of sync (German language only). 254207 - Big problems with CAD models 254670 - Positive Reporting Does not work when Feature Nominals are updated during execution 252979 - Report shows bundle as a page break with no data 253185 - Problems with the Audi_text labels 253021 - PC-DMIS crash during collision detection 252912 - 'older' label modifications get displayed on the duplicate page 257064 - Machine crash during execution 257100 - Executing the attached pp using the Marked Sets won't generate the RTF reports with the right names 257088 - The mirroring of the SCROs is broken 249677 - When you try to edit a couple of cells on a grid control object, if one of the selected cells is an ActiveX cell type PC DMIS crashes 248977 - Export of Auto Features Cylinder to IGES 249607 - Visualized label and selected properties are out of sync 255728 - scanning result is different between v37 and v42mr2 257375 - In the incorrect DMO file that is generated from the basic script that calls the pp.dmisout2 method (neu_P420110001.DMO) there're theoretical features without the existent of a dimension command (i.e. LK100) 257335 - Pc-dmis shuts down with a Runtime Error at the end of a Bundle Alignment when a Form is used at the beginning of the program 257278 - Not possible to save legacy reports in PDF format 256086 - Gauge Object does not update 257412 - Bad MID line construction between two very close lines 257661 - Leader lines are in wrong position 257634 - probe crash since the wrong movement after release E-Stop 255421 - tangent points and angles 242667 - True position results do not seem correct 254610 - Measuring an angle segment 256453 - The execution of the collision detection hangs. ******************************************************************************************************** ********************************************************************************************************