----------------------------------------------------------------------- Wilcox Associates, Inc. PC-DMIS® Version 4.3 Enterprise Metrology Solutions Installation Notes: ----------------------------------------------------------------------- 1) General System Requirements 2) Information about this release 3) New Product Information 4) Release Notes **************************************************************************** **************************************************************************** 1) General System Requirements Minimum Requirements:------------------------------------------------------ | | | • PC-DMIS® 4.3 operates under 32-bit and 64-bit (x64) WindowsXP® | | systems and 32-bit Vista Business®. No other operating systems are | | supported. | | • Pentium-IV or higher processor is suggested. | | • 1 GHZ or higher Intel processor. | | • 1GB of RAM is recommended but significantly more may be required if | | working with large CAD models. | | • 500MB of free hard drive space minimum for the application. | | • SVGA capable monitor. | | • DVD drive. | | • USB port available. | | • The computer must have a graphics card that supports OpenGL shading. | | We cannot specify an exact graphics card since every user has varying | | needs. However, nVidia is the preferred graphics vendor for PC-DMIS. | | • Nvidia GeForce video cards are not recommended for use with PC-DMIS. | | This is defined as a "gaming" card according to Nvidia Engineering. | | • Supports a screen resolution of 1280 x 1024 or higher. | | • RTF file output requires Microsoft Word to be viewed. | | • Microsoft® .NET 2.0 | | | -------------------------------------------------------------------------- Recommended Minimums:------------------------------------------------------ | | | • WindowsXP® 32-bit or 64-bit and 32-bit Vista Business® operating | | systems. | | • 2 GHZ or higher Intel processor for improved performance. | | • 2GB of RAM or higher. More RAM may be required if working with large | | CAD models. You should have RAM equal to 8 times the size of the | | largest CAD file you will use. (For example, if you use an IGES model | | of 250 MB, then 2 GB RAM is recommended.) | | • 1GB of free hard drive space plus allocated Virtual Memory of 8 times | | the largest CAD file used. | | • SVGA graphics card that supports OpenGL shading and that has WHQL | | certified drivers. On board video card memory should be based on the | | size of CAD file being used. | | • For use without CAD models, 64MB video memory. | | • For small to medium CAD files (50-100 MB), 128MB video memory. | | • For large CAD files (> 100 MB), 256MB+ video memory. | | WHQL (Microsoft Windows Hardware Quality Labs) video drivers can be | | downloaded automatically when using the Windows Update software. | | • SVGA capable monitor. | | • DVD drive. | | • 2 USB ports available. | | | -------------------------------------------------------------------------- • NOTE: Depending on your specific needs, the recommended system specifications for this version of PC-DMIS may be much higher. A more substantial computer system may be required to accommodate part programs using Automation or complex Reporting objects. Be sure to consult with your PC-DMIS distributor to find out the type of computer system you will need in order to run this software at its optimum capability. • IMPORTANT: When using 3rd-party drivers you should contact your local Hexagon representative to ensure Operating Sytem compatibility. • ANTI-VIRUS SOFTWARE: The Sophos® Anti-virus tool was used by Wilcox Associates Inc. while testing PC-DMIS. The performance of any other anti-virus tool will need to be confirmed by the user. (http://sophos.com/products/enterprise/endpoint/security-and-control/) • INSPECTION PLANNER: You may need to recreate the IPD file for needed parameters so imported Inspection Plan items are created correctly. **************************************************************************** **************************************************************************** 2) Information about this release. We at Wilcox Associates are proud to bring you this new version of PC-DMIS® 4.3 MR2. This Enterprise Metrology Solutions platform brings together new aspects of PC-DMIS® for the development of a complete manufacturing process control solution. Available in this release are variations of PC-DMIS® designed to assist with every aspect of the fabrication and quality control process. The newly created packages include PC-DMIS® Laser, PC-DMIS® NC, as well as the established PC-DMIS® Pro, PC-DMIS® CAD, and PC-DMIS® CAD++ platforms. Also included with this release is PC-DMIS® ONE, a simplified shop-floor DCC inspection package developed in cooperation with Brown & Sharpe. The testing of this version has been significant. We’d like to take a moment to discuss this process and also make you aware of the various components of testing. Testing is comprised of two parts. These can be described as functional testing and integration testing. The vast majority of testing effort goes on in the functional area. This is the testing that determines that specific functions that are core to the software, regardless of what type of machine is used, are working correctly. The integration testing is essentially a testing of the interface with a particular type of machine. In the ideal scenario, WAI would have access to at least one of every piece of hardware that is operating in the field running PC-DMIS®. However, in practical terms, this is impossible. This integration test plan is then performed on as many types of machines as we have available. Unfortunately, there will inevitably be machines to which we do not have access and that cannot be fully tested in this manner. To this end we have made an effort at closing this gap by partnering with our customers through the Beta Test Program. On our web site you will find an application for this program here: http://www.wilcoxassoc.com/usersarea/beta_test_application.php Should you experience problems with your system after installation of PC-DMIS® 4.3 MR1, it could possibly be an integration problem. If it is a problem of this nature, it will probably be evident immediately upon first use of the possibly untested configuration. Should such a problem materialize, you will be given the highest priority for correcting these problems. Please call Tech Support immediately to report any integration problems. For existing users of PC-DMIS who currently have earlier versions of PC-DMIS® installed, it is advised that PC-DMIS 4.3 MR1® be installed into a new directory. In this way, you can be assured of continuous use of the existing version should problems arise with this newer version. **************************************************************************** **************************************************************************** 3) New Product Information (Note: EMS products remain in Early Adopter stage until formal release of each is announced.) • WAI Toolkit - Allows for the creation of custom commands in PC-DMIS ---------------------------------------Major Enhancements--------------------------------------------- >>>Auto Features<<< • Circular moves for a Plane feature • Allow insertion of MOVE/CLEARPLANE or Stored Moves in between AutoFeature hit basics. • Ability to have Gap Only on by default • New "Read Vector from Machine" button for all features >>>Dimensioning<<< • Selecting the "Auto" option in the Location Dimension dialog box, will indicate the automatic choices with greyed out checkboxes (503994). • New dimension for Length of spline (503736) • New True Position In-Between (503412) • Support for 'A' Axes and Angle Point Feature (502897) >>>Direct CAD Interfaces<<< • Allow multiple file selection for UG DCI import (503159) • DCI connection status indicator (500841) • Replace UG translator libraries with improved libraries (503894) • Replace Pro/E translator libraries with improved libraries (503895) • Replace Catia translator libraries with improved libraries (503896) • Replace Parasolid translator libraries with improved libraries (503900) >>>Graphics Display<<< • Toolbar button to toggle the display of transparency • Display Symbols dialog box - allows you to alter parameters for display elements (radius,size, etc.) • Option to Auto Arrange Labels CAD Window Label (503743) • Hide labels during rotation (503741) • Tooltips functionality for features in the graphics display window • Animation for rotary tables • Collision detection function displays a dialog that tells you where the collision occurred • Features move on machine with fixture movement (503207) • Ability to show all features visible in view (503867) • Speed up path animation (503918) • Collision detection displayed dialog with list of collisions (503980) • Construct point from intersection of scan segment and plane or line >>>Inspection Planner<<< • Angle Dimension dialog box allows you to display the Angle between two Features (503173) • Distance Dimension dialog box allows you to displau the Distance between two Features (503173) • Path Optimization accounts for the machine volume (503317) • IPD defaults – one thickness value for all features (503378) • Assembly Support (503577) • Remember last 10 tolerances for use in dimension dialogs (503630) • Support for 321 alignment (503731) • Double click on feature in tree view to edit (502733) • Add point density option for 3D scans (503816) • Enhance IP defaults file to support app PC-DMIS measurement methods (503899) >>>Languages<<< • PC-DMIS now supports the following additional languages: Polish, Russian, and Turkish >>>Laser<<< • Density filter to limit data in a laser stripe • Ability to scan points in learn mode from an arm or laser tracker • Sound events added to play wav files for events (mostly laser events) • Real time shading of laser scanned data (503376) • Ability to extract measurement data from laser scans for laser autofeatures • Laser Autofeatures now show measured stripe data in CAD • Greysum material list with associated min and max pixel intensity values • New Cylinder Laser Auto Feature >>>Portable<<< • Ability to indicate if they are building or inspecting to points • Measured points display location for all axes. • Hidden Point construction capability • The Probe Readouts window can report the current feature based on the location of the probe/reflector when executing • Allow the user to control if the data is displayed as probe compensated or not • Color the deviations in the probe readout window according to the dimension tolerance color • Stable point probing for Leica trackers • Alignment that allows the user to specify which axes of the input feature to use during the alignment • Edge Point Mode allows for walk-up measurement of sheet metal features without using the auto features dialog box. • Auto-Inspect mode: Provides automated inspection of a sequence of points using a Leica tracker. >>>Probes<<< • SP25 Probes use a new and improved algorithm in the CoScanning.dll file rather than the older CALRSP.dll. • TRAX or PMM calibration type for Leitz machines in Probe Calibration dlg • Disk Styli are now supported with the SP25 probe • A simplified partial calibration procedure is now available for an SP25 that has been fully calibrated at least once • The LSP-X1 family of analog scanning probes are now supported • Display inactive tool tips in “disabled” color (503811) >>>Reporting<<< • Automation - New properties of a Report and Section that can be set by Automation (ER #502959) • Ability to report if a feature has been skipped during execution • Color ball on Label Layout Wizard should be able to show dim color for selected range of axes (ER #503646) • When editing CAD in the Report Window, the mouse's scroll wheel can zoom like in Graphics Window (ER #503025) • Show dimension labels for point cloud on report (ER #503373) • AudiDraw Converter - PLT(HPGL) file generation (ER #503632) • Ability to control the size of text in grid control object (ER#503828) • AUDI WBZ: Ability to scale the section cut object (ER#503856) • Transparency for the grid object control (ER#503830) • New report expression functions allowing the user to see the report-level OOT statistics (ER #504154) • New dat file control (EH#504269) • AudiDraw Converter - PPM file generation (ER #503632) • WEBASTO Utting: Duplicate page method to custom reporting (ER#504226) • AudiDraw Converter - New advanced property, Wireframe, for CadReportObject (ER #503632) • AUDIWZB: Shaded/unshaded as property to the CRO (ER#504282) • AudiDraw Converter - Show CAD layer on the CadReportingObject (ER #503632) • AudiDraw Converter - Mirror the CadReportingObject (ER #503632) • AudiDraw Converter - Make Leader Lines terminate at two features for distance and angle on CadReportObject of Custom Report • Ability to edit leader lines on the report (ER#502833) • Webasto-Schierling: In the DimensionColorKey object you can change the properties font and font size (ER#504381) • AudiDraw Converter - Expose objects on Custom Report (ER #503632) • Ability to re-order pages on Report Window (ER#503397) >>>Vision Measurements<<< • New Polygon, Notch, and Ellipse Vision Auto Features • Auto Feature Guess mode for Vision • Quick Start support for Vision • Full Scannings Support for contact and laser probes • Speed Improvements in Edge Detection • Speed Improvements in Focus • Selective Sampling (e.g. measure 30% of feature) for speed • Auto sensing for focus to only do a focus when the edge is blurred (CAD++) • Gage arcs draw as arcs, not full circles • Protractor Gage length can be changed without changing angle • Auto Feature button to adjust surface vector to current probe vector ( <--- this could be in the general auto feature section) >>>Vision Live View<<< • More quick access toolbar buttons (Snap To Edge, AutoShutter On/Off, Compass On/Off, Show Target) • More user control over when AutoShutter and Compass features are used • Easy access on right click menu to quickly edit or move to nearest 10 programmed features • More edge detection parameters can be set from right click menu >>>Vision Illumination<<< • Intensity value for current mouse position shown on live view overlay • SensiLight auto illumination adjustment prior to edge detection • Option to switch off illumination on vision machines at end of execution • Option to restore illumination to previous settings at pc-dmis startup >>>Vision Hardware<<< • TESA VISIO 500 support • Add functionality to optionally use a projected grid during focus • Temp Comp added for Vision machines that support this (Visio 500 & Mycrona) • Added support for VISIO 300 red LED ring light • Stacked Rotary Table Support • Dual Camera Support • Matrox Solios support • Matrox MIL8 imaging library support >>>Misc<<< • Export XYZ option • Save As allows to save the CAD file as reference • Ability to export alignment information to a GDS file • Export to Excel Spreadsheet • New Dimension Color window • Probe Readout Setup dialog box as many new features to control the display on the Probe Readout window. • UMESS Translator • MeasureMax Translator • Propose default name for viewsets (503400) ****************************************************************************************************** ****************************************************************************************************** 4) Release Notes Version 4.3 of PC-DMIS is a significant development release of the software. 4.3 Release Date: June 2008. 4.3 MR1 Release Date: Dec 2008. 4.3 MR2 Release Date: July 2009. **** Prior to the release of Version 4.3 MR2, Version 4.3 MR1 was last official release of PC-DMIS by Wilcox Associates, Inc. and the Brown & Sharpe Metrology Group of Hexagon Metrology. Notice: PC-DMIS Database support for Microsoft Access does not exist in Version 4.3 MR2 -----------------------------Miscellaneous Enhancements and Fixes-------------------------------------- Known corrections and improvements from Versions 3.7, 3.7 MR3, 4.0, 4.1, 4.2 and 4.2 MR1 that have been resolved: 239830 - Turn different scales back on the rulers in the report template editors 211323 - Add RMeas to all Autofeatures 222393 - Cannot open SW DCI program to view CAD and PRG if solidworks is not available 230345 - Problem with "Automatic Label Positioning" to be on by default 230692 - Hidden elements show up as already deleted in the Delete CAD dialog box. 233714 - Measured Plane: Location reporting different Z location and large flatness value when measured with multiple tip radii 235617 - AutoRoundSlot: FindNoms mode not solving correctly when in Curve Select Mode (Online Leitz) 235934 - Spherical boundary conditions with scans do not stop with changes to radius or # of passes but always terminate scans at the center point of the boundary location. 236272 - Automation/Reporting: Bitmap property of Bitmap object prompts for file when property is set 236292 - The command "DmisParts.Add" opens a file (*.PRG) without a name. 237074 - Serialization error: No error occurred / the application crashes when shading the model 237841 - Check speed should be set to >0 for a DCC Vision machine 238465 - When executing a part program, hitting the ESC on the keyboard does not stop execution 238602 - application error when changing FCF dialog tab selection after viewing nominal values 238621 - The CAD model of the wrist is partially hidden or it disappears 238653 - Single entity selection ignores Edit/Delete CAD dialog 238978 - AutoCircle: PC-DMIS hanga during creattion 239119 - Creating auto circle features using box select in the Graphics Display window creates circles with the same feature ID 239142 - IPD file is not consistent: Remove ‘measured height’ property for the round slot 239582 - With a disabled SW DCI license we can still select wireframe/point geometry 239609 - AutoCircle: Need to be able to solve during learn mode with a Single Point 239698 - Need to execute a COPOPER/EXPORT command to get the output, Apply does nothing 239714 - Vision probe offset processing corrupts the part program 239742 - Existing copoper commands are available and executable without Cop option in the lock 239758 - Several auto features are missing the Display Hits and Show Details options in summary mode. 239764 - The report dimension colors do not match the edit window colors 239792 - Sheffield controller with Tesa Star M auto Sphere out of memory error message 239798 - Icons are split, incorrectly aligned on layout bar 239894 - It's impossible to assign specific CAD features to a layer 240126 - AutoRoundSlot: Laser: Array not large enough causing crash 240444 - Command mode does not show print options for form 240781 - Loading a contact probe after a vision probe, will not be animated on the cad during execution 240872 - AutoCone: dragging hits problem 240908 - Problem with the list of the features in the FCF dialog box 240946 - AutoRoundSlots: Should not be able to drag hits off the surface 241013 - AutoCircle: Single-Click selection of arcs, AngleVector causing problems 241210 - RunTime Debug - using uninitialized variable if you change illumination following a bad calibration 241280 - The field of the type of Tool Changer should be longer 241343 - AutoNotch: feature dialog: ‘0’ is missing as item in the combo boxes for the sample hits 241409 - Metronics device driver is sometimes not installed 241506 - CAD detection within Find Nominals tolerance fails when no CAD is imported 241540 - Radial auto plane: Need to be able to select '1' as row number in the 'row' control of the probe toolbox 241674 - Spacing is not consistent between dimensions on TextReportingObject when "Use Text Mode Dimension Reporting" is checked. 241704 - AutoSurfacePt: Copy/Paste, thickness value lost 241722 - Marking and block executing a constructed Cop offset point results in an empty pointcloud 241818 - Ctrl+E doesn't work for COP and COPOPER commands 241904 - Add support for more than three cad element types for the autofeatures 241913 - Readouts window is defaulting to only having two fields on by default - Mag and Hits 241975 - Constructing a set with PNT[1..6] get_inputs() returns individual PNTs plus CPCDsearch_id for the set so have 7 inputs 242022 - ReadPosUpdatesXYZEvenIfRMeas=False doesn't seem to be working right 242169 - No indication is given of illumination gray scale / intensity 242192 - Vector/Surface Point with CAD using Find Noms and joysticking to learn feature finds incorrect nominal 242252 - cadonly.rtp produces black and white output after page 10 242330 - IP Defaut File: Can't select thickness type NONE in the IPD file 242395 - Probe tip is not the same as when you select View/Settings from the toolbar 242468 - The probe is no longer displayed for all AutoFeatures types while creating features 242477 - EdgePoint: Target coordinates are converting to 0,0,0 on import of a v4.1 program. 242544 - PC-DMIS crashes when importing IGES file 242591 - Laser Flush & Gap missing TARG coords 242595 - Save As version 3.5 does not save the CAD 242626 - Cursor - Cross not working 242753 - Perpendicularity tolerance is being converted to metric in the report, even though the dimension is being set in inches 242808 - Markings do not update in Summary Mode when clicking a marked set button/icon 242865 - labels are displayed bigger with V3.7 than with in V 3.25 242886 - Wrong vector on measured cicle hits 243127 - Proessing the ReadPos button (in the Move To dialog) successive times adds 3 to the Z value 243305 - Hit data not appearing in RTF file 243504 - Unable to add FORM command by automation 243998 - Equate Alignment not working as expected. 244382 - AutoCircle: View perp and normal for Arc Stud zooms in too close. 244388 - AutoLine/AutoAnglePt: 'from Feature' Offset Moves result in collision 244391 - AutoWrist selection incorrect for 4 AF types, collision possible with 2 244405 - Cells not merging properly in report window 244760 - Cannot create vector points on the attached Catia 4 model file 244769 - Variable names are overwritten by default values in Assignment dialog box 244909 - Need to be able to resize the input window when docking the Probe toolbox 245038 - AutoLine: Depth should be utilized in AvoidanceMoves 245056 - Cannot select autofeature vector points on translated step file 245243 - Step files not allowing for seprate entities 245956 - Leader lines for FCF dimensions in graphics window break down under Automatic Label Positioning. 246008 - Status window must store its size 246080 - Surface is missing in DCT file but present in DCI 246107 - Copious data element does not show its XYZ/IJK values in CAD Info 246223 - DES file problems 246224 - Strange results from alignment 246392 - Improve the speed of the PC-DMIS to Excel wizard 246454 - Inserting specified constraints alignment command fails 246617 - Reference features are lost in the part program 246864 - LSP-X3t not nulled after tool change 246902 - Flatness Per area data truncated in PPAP report 246965 - Exporting as an iges file, polygons are now circles 246980 - Missing the 'ending offset' on the cylinder in the IP Defaults file 247003 - CAD Transform: Specify Rotation Matrix does not work as specified 247066 - Datum constraining of a plane producing bad results 247277 - Perceptron/Metris and Vision Live Views don't work nicely side by side 247341 - IGES File Import Problems 247353 - Activating a secondary axis in an Imported Catia 5 PRODUCT yields incorrect results 247359 - AutoSlot: Can’t switch off the UsePin option on auto slots 247385 - Cant Click on some surfaces from a Catia or step CAD model, when Alternate Iges Import is set to false in the settings editor 247396 - "Page Width" does not scale to the full page width if landcape 247451 - View Path Lines shows vectors in Z for XY plane probing 247452 - AutoCircle: Incorrect diameter calculation 247542 - Wireframe not tied to rest of ProE model 247567 - 2D Profile Edge Trace doesn't show all the measured points 247618 - Most circles on new HexagonDemoSlide are treated as 180 degree arcs, not the full circles 247624 - Program pauses without error when doing a READPOS 247672 - Crash with invalid #BMP in logo.dat 247761 - The messages for operator (Operator Comments) are repeated without motive 247827 - Home positions taken anywhere after timeout 247875 - Communication error: Wrong parameters in the file ISO - 10360-4 248057 - Auto Cone: Creating an autofeature from automation basic script causes incorrect hits 248080 - Part program hangs when performing simultaneous expression and underlying input commands have been executed 248465 - When contact autofeatures are called, the pathlines are drawn 3 times 248468 - Error: "CAD file could not be read..." 248536 - Pin vector for slots is missing in the IPD file 248537 - Number of sample hits for slots is not used 248648 - Create a circle with scan minimum doesn't work with profile 2D : construct a circle with scan is working! 248674 - Support importing IP plans by reference 248770 - AutoCylinder Stud: stylus collision when using ReadPos with no sample hits 248772 - Wrong nominals from CAD when EDGE POINT ONLY function is activated 248774 - AutoEllipse: Erred distribution of the hits on the plane 248830 - Wrist orientations are not saved per machine 248919 - No difference in actual vectors between LEAST_SQR, MIN_CIRCSC and MAX_INSC constructed cylinders 248999 - Calculate Curve Length 249008 - No default curve type creating a LinearOpen scan with Perceptron 249170 - Arm1 probe file has 150MB, arm2 probe file is 30MB 249488 - Hit coordinates on the Hit Targets tab deos not always reflect the currently active alignment 249845 - Problem constructing cylinder from 3 scans to points 239580 - It takes longer to re-load a previously loaded model? 247122 - Optics Calibration Fails on CMM-V 249060 - If the auto focus fails during the optical calibration (FOV Rectangles) the calibration continues without reporting an error 249596 - Selection of labels must be type depending (change only defined) 248259 - etool issue with inspection direction 249828 - The calibration tool 'Ring' is not available 250123 - Simulation of the part program show a move which is not existing in the part program 249859 - Not able to indicate points on certain areas of the attached CAD file 250230 - FOV calibration does not work when selecting ring illumination source 250143 - Serialization error opening program - FCF True Position 249573 - Simultaneous evaluation giving serialization error 250379 - Offline indicator on status bar misleading - says offline even if online 247805 - None of the dimensions created from an IP Translation appear in any of the reports (standard and others) STAT is the default option for dimensions. in the IPD file. 250829 - Incorrect surface after PRO-E DCT import 250694 - PC-DMIS crashes when constructing a plane from constructed sets 250349 - The path lines have collisions with the probe hardware when doing optimize and then auto path 250351 - Ordering of features not logical for on feature (vector point) 250687 - Perimeter Scan Flips vectors 243718 - There is no notification if license server has invalid license file for install 243376 - Use of CMMI.DLL as name of CMM controller (e.g. LEITZ) for CMM-V is causing problems on demo locks 251420 - The "Show Measured Points Toggle" button doesn't update the Graphic Display window 249574 - Graphical evaluation of roundess and flatness GD&T is wrong but fine for corresponding legacy dimensions 251671 - Should not allow calibrate button to be pressed on rotary dialog box, as it doesn't work 251559 - Unable to load DLL ActiveX.ocx message during installation 251582 - Laser Probe Toolbox toggle button still shows if Laser Probe controller is set to NONE 251128 - UID not being translated for FCF or DATUM IP commands 252555 - Exported nominal features do not all match UG prt file in Unigraphics 251577 - Polar coordinates does not produce the correct vector 250674 - VISIO 300 sometimes signals move complete too soon on a SetPosition call that immediately follows a focus 252195 - Perimeter scan path generation produces opposite vector initially but corrects when using F9 and regenerating 249469 - PCDMIS drives probe into tool changer 252331 - Serialization error:Pointcloud loading " Iso 10360-5 Perceptron Multistylus Bridge.PRG " with the current 4.2RC diskset 232525 - Calibrate the Unit for the Arm2 laser produces an application error on the Arm2 computer 253679 - DMIS CONCAT command doesn't import correctly 253839 - BestFit ocx label is too wide now not all information are visible 251381 - PDF-Printing from CAd REPORT shows wrong origin 248903 - Unigraphics Translator model shows irregular surfaces compared with v3.7mr3 243966 - Many of the Tracker Settings pages tabs are not complete 254385 - Single click on a square slot on the Volvo car body returns random square slots numbers 253874 - TESA: FramegrabberInstallerMil80 : Error occured during driver setup 253469 - Attached Part program take an excessive amount of time before execution begins 246791 - DMIS import dialog does not remember its settings 239801 - We prompt much too often about Plus & Minus tol must equal FCF tol 250331 - Are there issues with dimensioning Runout from 3.7mr3 to v4.1 244543 - Probe Changes are not beeing seen during execution 251572 - Leader lines do not end at their related labels ----------------------------------------------------------------------------------------------- Version 4.3 Maintenance Release 1 (Additions After June 26, 2008) 251932 - Gage Size handles not drawing correctly with rotary table 252730 - Edge Tracer doesn't work on CMM-V 253441 - TESA : Impossible to measure this profile with auto-feature profile2D (Vision) 253777 - Sensilight does not work if the target has 'ALL OFF' for illum setting. 253827 - Slot auto-feature : Using the new possibility in vision mode, measure a % of complete element - target return no points 254178 - Filtered Points on Ellipse not shown - icon is greyed out in PTB 254179 - Edge detection direction arrow is now same colour as feature target 254236 - Rotary Scan - when edit, you can't see the "nominal circle" drawn on the CAD until you put the focus in the radius edit box, and tab out of it 254263 - FOXCONN: Need to keep on pressing Next button in Quick Start and no hot key available, when building dimensions and constructions 254583 - Parfocal/Parcentricity calibration Check box and Status message are contradicting with each other. 254613 - When using double-click to program a full circle the start/end angle do not default to 0 254644 - Metronics needs more informative error messages 254645 - Need to grey/hide unnecessary scan options for Spot Sensors 254759 - Parfocal calibration : normal accuracy has a very short focus scan if no depth of focus calibration data 254898 - QS in CAD view - left clicking the centre of the FOV causes machine to move 254900 - Crash when trying to create slot on CAD using Curve Mode in Quick Start 254963 - Editing a patch scan and changed Tech 2 Inc has no effect on the scan 254395 - Sensilight doesn’t work when bulb set to 0 254614 - When exporting a 2D profile to IGES 2D it exports the measured points when you ask for nominal info 255241 - Rotary Scans RELEARN mode are attempting CIRCULAR MOVES on machines that may not support it 254991 - MYCRONA: Time for linear open scan increases when running the scan in a loop 255254 - Positional Laser button is showing on probe toolbox on machines that don't have one 254653 - Laser spot button keeps on turning off 255207 - FS#727 Cannot Import Catia v5r17 255874 - pierce point is wrong 255055 - Circular move problem 255172 - Although multiple Cop objects can be selected in the Alignment dialog, points can be taken only on the first Cop that has been selected 255212 - Bestfit alignment shows wrong feature labels in report 255445 - TESA: Visio200 : Unpredictable control of the illuminations with ToolBox slide 255317 - Cylindrical Gauss Filter : Outlier Removal Problem? 254351 - Quick Start does not work with CAD View in when a vision probe is selected 252586 - Hit targets not displayed in Polar coordinates 255808 - VISIO 200: Need updated DLL added to the install 255834 - BF2D least squares alignments not working for workplanes other than Z+ or Z-. 255688 - WLS scan doesn't work in inches 255653 - Frequent but random crash during rotary table calibration 255666 - Vision Round Slot creates incorrect when in Polar Coordinates 256067 - Post out index numbers exceed Heidenhain variable limits 241933 - During path optimization feature labels appear temporarily 255793 - Editing al label and taking out columns, there is a different behaviour between report template and custom report 253375 - Also the 'distance line' should not do through the label 250566 - PC-DMIS goes into endless loop if Report Mode for embedded report command is set to SWITCH 252730 - Edge Tracer doesn't work on CMM-V 252944 - Guess Mode not working - Only points are being registered 254006 - Unnecessary messages when swap in dual camera 254411 - TESA: Give feedback on Optimet signal quality in user interface 254647 - Probe toolbox disappears if you cancel the auto feature dialog 254648 - Auto Feature dialog default opening position is bad (for vision at least) as it makes the Live View and Cad View tiny 254759 - Parfocal calibration : normal accuracy has a very short focus scan if no depth of focus calibration data 254900 - Crash when trying to create slot on CAD using Curve Mode in QuickStart 255094 - Popup menu on command mode shows ANGLE POINT option for vision probe, but it is not available 255307 - execution ROIs are incorrect 255337 - Vision On Error Causes Crash 255340 - Feature focus using inches has inappropriate Move commanded outside travel limits error 255403 - A added page in custom report is allways vertical, even if orientation in repport settings is set to horizontal 255458 - Surface Variance value appears to default to 1 whether in inches or mm 255544 - Profile 2d feature doesn't operate properly in Best Fit Alignment- it should show individual points like a scan 255549 - Application hangs in an infinite loop in the path optimization - ESC must be used to finish the operation - The path optimization is not working any longer in V43R 255603 - Quick Start Line has incorrect vector 255613 - Probe head not always drawn in the graphics window 255614 - MODE/MAN and MODE/DCC commands are 'broken' 255615 - ParseError during the import of the HOLES_IOP inspection file of my reference part 255622 - The angle vector on the auto square slots changes during the optimize path operation 255649 - Serialization Error on commentized commands (due to not being supported in a particular version) 255758 - Can't display the '400 label limit' warning 255789 - Graysum: material is changed from Tungsten to Custom when the feature is created 255876 - Multiple "Clean Filter" and "Outlier Filter" entries in EditWin summary mode 255879 - Crash when create a vision feature with all lights off 255900 - When I create a new Legacy (Hyper) report with v4.3 and add a CAD image and several labels, they are not saved 255901 - Inversion of the directions in the measure of Angle-Point, after a change of the Thickness 255924 - Joystick enabled during homing 255943 - Crash clicking in the Pointcloud Operations Steps window to edit an Import command 255949 - Freeform scans move at the wrong speed 255951 - Can't hide the assembly nodes in the graphics window from the CAD assembly dialog. Part and fixture are still visible in grey even if all nodes from the CAD assembly dialog are unchecked. 256021 - When is asked to bisect the sphere during the qualification of a laser sensor the live view is disabled 256049 - The collision detection is using also the hidden CAD objects 256062 - Some string operations step over string array boundarys 256073 - ACTL Thickness is not applied when Theo values of AF's commands are modified from EW 256119 - In 43MR1 the Measure Probe dialog has some new features, but unfinished and not documented 256170 - This part program crashes during loading and seems to point to a bfre issue 256206 - Tesastar Probe allows for angles 256250 - Problems importing Catia5 R18 moldels using DCT 256273 - Crash importing in 43mr1 and 44b PSL files created with 43Release 256452 - The Probes disappear from the end of arm when the user opens the probe dialog 256491 - FOCAS read of negative integers off by 1 256738 - Cad selection during execution for laser autofeature alignments is hanging execution 253883 - The 'Scale Factor' in the section cut profile dialog is not working 255684 - In XP, the axis letters doesn't appears in thriedron when printed in PDF (Vista is OK) 255178 - The label select dialog can't multi select labels 255822 - Lines with doubled thikness, not going to the feature centroid and not straight 256600 - PC-DMIS experienced an OpenGL Tessellation application error after saving a program 256481 - MoveCircular::execute() doesn't use interpolated moves when simulating. This cause false collision when doing collision detection 256568 - The Scrollbar is sometimes missing from the EW 256631 - Program loading reports image size mismatch between probe and framegrabber 256382 - Cannot dimension mulitple instances of loop features in GDT dimension window 256001 - PC-DMIS V43 locks up running a V42 program 254239 - Default Feature Tolerances dialog is missing Profile2D feature type entry 253816 - CAD slice returns too few points 253697 - Un-install does not remove Tracker files 250139 - Why do I keep getting this message about probe diameter error exceeds the limits? 251971 - Automatically marking features now? 253880 - All 'Audi hole' labels draw with an unwanted extra line on top of each label 255166 - VISIO200: Manual Turret support uses "simulated scale" resolution of 1 to 1x. Round errors in the mag processing could lead to the wrong x being requested. A higher resolution simulated scale should be added 255513 - PCDMIS crash doing drag and drop in a dimmension to a grid objet 255777 - Bitmap object has too small of a color pallette 256638 - Application is crashing it the ‚Update part program' operation 256659 - Profile Line Form Only on circle not correct, includes positional error 256743 - reference the CAT part, probe crash component not turning red 256745 - Perceptron V5 on portable machine: Getting "No Scan Data" when extracting an alignment AF from a pre-existing program's cloud 256761 - Laser calibration: "Ok to save partial calibration data" 229606 - "Attach External Part Program" option does not show up when under PCDMIS PRO mode 256401 - Edge features are getting the wrong thickness by exportIP process 256399 - Design side gap feature imported incorrectly 256652 - Add Edge Thickness and Edge Thickness Type to change manager 256708 - Chrysler issues #36 and #37 256489 - Boundary type is not shown when probe type is a scanning probe 256808 - Problem reloading pp using part/machine set-up 256133 - Crash on FIle|Exit 256033 - CMM-V Value Smaller than Permitted 256357 - 2D Scan dumps PCDMIS - TESA Visio 255496 - Adjust filter data in edit window is wrong 256411 - Adjust filtered set can't be marked for execution 256809 - Problem selecting on CAD after doing a CAD transform 256896 - Running collision detection multiple times in a row is causing a slowdown 256955 - AUDI NSU PRESSWERK - PCDMIS is crashing after hide cad models with the CAD Assembly Dialog and the pp is save under new name 257004 - Measure Mode box is available on the auto dialog for laser features, but it has no options inside it 256668 - MYCRONA: WLS measuring range gives bad results, needs to be indepedant of tracking distance 257202 - PSL export is not working correctly 257014 - Crash creating cross sections on this 4Mpoints cloud 257015 - Cross Sections: the View function is no longer working after the first change on Delta 257076 - FindNoms Override: incorrect when applying 'Search Priority Surfaces Only' 252245 - Laser stripes are shown when i load a program which has a Laser AF in 234146 - Laser Scan: The Edit Window is showing options that don't exist 256265 - draw path lines draws prehits on analog scans, these are unnecessary and collision detection collides wiht them as well 256549 - Cannot create Vision Square Slot and Notch Slot feature using AF dialog 256533 - After calibrating a probe tip, the graphic display of the probe in the Probe Utilities dialog is skewed 254995 - Custom reports are not drawn in the report window (and are not printed …) 255733 - Frame Grabber fails to detect 247662 - Label properties and information in the label propertied dialog (IDD_HYPER_GRID_LABELS_DLG) are out of sync (German language only). 257104 - Change Manager is adding all features with theo thickness as OM 256830 - IP Import "hangs" when importing attached file 257661 - Leader lines are in wrong position 257848 - No backup created 255970 - Out of memory errors in v4.3. program opens fine in v4.2 256197 - selecting curve data behaved better in 3.7 256176 - After executing this program in v4.3MR1 with Windows XP I get an application error 256313 - If I click select a LASER_AUTO_CIRCLE on the CAD after and AUTO_CIRCLE the depth value always changes to 360 256334 - The click selected diameter of the LASER_SPHERE features is always 360 256029 - Using CAD (NOT CAD++) the SCAN SPEED instruction is not available (Line in RED in the PP) 256157 - No hit counting for Manual scans 255187 - When I open this program and then select File/Quit, I get an application error 255640 - Step file missing surafce when imported to Pcdmis 255606 - Can not plot data with Graph object 256897 - In 4.2Beta in auto features, the probe would flash for a second and then disappear 256939 - Parfocal cal creating unnamed fvc file 257077 - Temporary probe color not sticking 257022 - Profile evaluation is done different than in 3.7 even if you choose "37 compatible" 257074 - The probing on the graphics window behaves differantly from what it should for taking hits in 'program mode' and in 'auto feature mode' 257055 - Problems with workplane selection 257035 - Unable to ignore probe components during collision detection 257036 - Selection during point cloud alignment is persistent 256565 - Clicking (elsewhere) in the AutoLine dialog, the vector changes 256552 - FS#951 - Application Error during CATIAV5 DCT Import 256620 - Program from CAD offline. Then run online. The measured values are not correct 256408 - Part and probe behind components of a transparent machine are not visible any longer 256461 - Not able to edit a laser scan 256454 - The auto insert moves operation is broken 243217 - When the user moves a fixture in a part program with an iterative alignment he get asked to measure the alignment features 255873 - Optical center calibration / adjustment not being applied 256706 - IP not handling scans properly 254054 - The execution of laser scans on Arm2 results in an empty Cop, or hangs if combined with AFs execution 257205 - If laser initialization fails, then exit menuitem remains dimmed, etc. 257198 - Attempting to scan before a program is open causes a crash 257200 - Program created in V44B and SaveAs to V42 crashes in graph3 when loaded in V43B 252089 - Composite Surface profile does not evaluate lower frame correctly 251090 - metric Closure Window shows four decimal places instead of three 257098 - Can't execute an auto circle offline. "Move commanded outside travel limits" 257090 - Can't use a probe built using the TESA_V4ix_SENSOR TKJ component, i get a message about not being authorized to use a laser probe 257173 - too slow doing execute and collision detection 257502 - auto cylinder and cone don't perform measurement behavior 257174 - Vision probe tip offset cal crashes 257352 - The Gap features (OM) are not unwinding correctly with change management 257237 - DEV PERPEN CENTERLINE is always OFF regardless of IPD file setting 257420 - Serial Data Capture program crashes with arguments 252113 - TESA: Visio500 homing failure when you rehome at already homed position 253804 - Auto Circle is broken, it leaves the autofeature dialogue open when executing a feature, if I try to close this then pc-dmis hangs 256543 - Assertion error when create a small slot feature 256850 - An unhandled execption is causing an application error in the constructed line dialog 257081 - The change manager is adding a new feature instead of replacing a modified feature 257082 - The change manager lists a dimension as 'Update Candidate' that has not been changed 257121 - AUDI NSU PRESSWERK - PCDMIS crashes at 99% serializing the cad when I save the program after using the Transform dialog on this cad file 257181 - An invalid argument was encountered during the Import of Inspection Planner 257197 - can not get Auto vector point anymore after mirror of the CAD file ( STEP) 257234 - TESA: VISIO300 : Homing Failure - Often wait for ever with message "Initializing-The-Machine" 257250 - True Position report problems 257262 - PC-DMIS aborts on export to AIMS 257264 - Probe file is corrupted when tranferred from Arm2 to Arm1 and viveversa 257269 - Profile of a CopOper crossection from COP will ge only a zero result in Profile dimenstion 257270 - Using COP or COPOPER causes application error crash 257326 - V43MR1 does not initialize the machine 257360 - Probe orientation does not stick for new machine 257373 - Deleting the statement LOADMACHINE an application error appears 257378 - Portable Execution Mode isn't stopping at subsequent alignments or load probes like it should 257379 - Surface selection failing on many surfaces in the attached models 257398 - Live View and Mini-Viewer does not display surface 257488 - TESA: VISIO200 : Manual zoom compatibility issue 257495 - Crashes when executing scanned feature 257533 - Trying to load the attached model with NX 6.0 produces an error 257538 - Error in Ax when refining alignment with Scan 257564 - The probe of Arm2 change the offset of the TIP, when is used on single arm 257596 - PointCloud point selection is not working after alignment 257601 - Square Slot: end hits not at center of width 257625 - Incorrect XY deviation for PointOnly mode and FindNoms 257629 - Hitting F9 Edit Feature function key will corrupt whatever auto feature is made and then edited after creation 257722 - Portable exection is sometimes not stopping for "Scan Done" button... also, not allowing user to take more data 257741 - different values for "m_pPartProgram->m_OldCadRotationAndOffset" when saving back to V42 257746 - Auto-position fails 257761 - Can't execute any move or auto feature on the arm2 machine offline. "Move commanded outside travel limits" 257830 - PC-DMIS crashes when exporting psl a cop and the cursor is at the begining of the part program 257858 - warning comment is missing on initial import that identifies features with metal thickness of zero 257860 - For OM flanged features depth is negative 257881 - CFEAT/SET command does not import to PC-DMIS 257897 - Can't execute the pp Offline - 'Move commanded outside travel limited' shows at least in one of the both execution dialogs 257906 - Manual Execution of features is not updating for each hit 256460 - Audi WZB - PCDMIS is crashing, when a Cad Report with 2 CRO's is used and customized by user 257825 - Graphical reporting of features is not working as expected 253386 - Intial Vector does not effect anything when used in a Basic Circle Scan PLANE type selected. 257832 - Catia v5 DCI missing surfaces 257845 - SCROs are empty when I open a v42 pp in v431 257979 - The Application is crashing in the CAD transform Operation 250981 - Bundle Icon on Toolbar is wrong and no longer the same as it was in 4.2 257168 - Cannot see cad surface in MiniCad View in Probe Toolbox Magnification Tab 256935 - Probe commands getting marked when not needed in Marked Sets 256397 - PCDMIS crashes if circular moves selected for an auto plane on redraw of pathlines 256453 - The execution of the collision detection hangs. 257622 - Wrong construction of from a circle on a cone 257695 - Tthe metrocom.dll is not installed. Needed for an old Wenzel machine. 254161 - The Ctrl+U command provokes a wrong rotation of the tip on Arm1 254515 - TESA: Point Density ignorred on TESA VISIO 500 Laser Scan 254892 - TESA : click on the part of program using touch probe cause machine move, activate a probe machine move (few mm) 255618 - Import of IPlan HOLES_IOP from my reference part takes 4 mins longer now than in V42R 255693 - Auto Wrist is creating bad angles (not perpendicular to the feature) 255800 - Crash canceling the execution after an out of volume error caused by armarm not present 255938 - PC-DMIS prompts the user to load the vision probe during DCC operation 256011 - SensiLight not working 256193 - Avoidance Move with Distance is not modifiable. 256253 - No Emergency Stop error when e-stop is pressed 256311 - Can't access the 'Depth' parameter of a LASER_CIRCLE_FEATURE feature through automation 256346 - Column Sampler: regular spacing not applied correctly when used with Graysum 256425 - an unrequested Startup dialog 256559 - probe orientation not recognised (sheffield) 256806 - AUDI WZB Report loosing SectionCutProfile views, when opening in the actual Version 256956 - Commands auto changes the arm assignments when serializing/deserializing a dual arm part program. The execution hangs 257000 - Click selection for an auto flush and gap feature in a local alignment returns the wrong XYZ nominal 257204 - Cannot select circle 257239 - Laser settings are messed up in Summary mode for Perceptron scans 257319 - The first problem we have is that when we load a dual arm part program then on the arm2 computer PC-DMIS is crashing. 257353 - PC-DMIS crashes after qi-runtime exits 257376 - Circular runout (FCF) created in V42R MR2 is corrupted when loaded in V43 MR1 (V431) 257462 - When the filename in a Load Probe command gets changed by automation a message arises and the application crashes 257501 - SYSTEMS 4 LOCAL : execute the the auto circle meansurement in manual mode pc-dmis crash 257614 - SYSTEMS 5 PL : "Powertrain" is not exposed in the portlock module list 257815 - Excessive errors of measure using two maps, one for every probe. 257925 - Installing 4.3 over 4.2 results in a crash on startup. 257998 - Arm2 circles with 'FIND HOLE = CENTER ' option does not execute 258003 - Page numbers in the PDF file are messed up 258025 - Settings Windows when use in Spanish shows the opposite 258168 - Name editing do not work in Edit Window. 258257 - successive calibrations in 4.3 increase working offsets, tool moved = NO 258320 - Can't make Auto Plane from Point Cloud 258322 - Feature Type box on the Auto Feature dialog is not correct 258331 - COP Color maps are very slow 258338 - New Program, go right into laser Qual, Gray Sum setting go to 0, 0 258340 - "Standard Deviations for probe calibration exceed limit" Failure dialog always displayed after perceptron probe calibration 258341 - no way to 'erase' a point taken on the point cloud when doing alignment using auto features 258357 - Calibrating Laser V5 on a Romer gives lousy results at anything higher than 10 Hz. 258392 - Auto Laser features fail sometimes because of wrong data passed from the pointcloud to the feature extraction toolkit 258450 - Changing the 'Ring Band' setting on an auto feature applies globally 258454 - Extreme slowness extracting Surface Points 258522 - The overall flatness does not consistently carry over into the report. 258578 - Slave probe pin data from Master computer is expanded by 25.4 times 258582 - Critical comment line missing from Penelope output file 258659 - When I F9 on a feature in a local alignment the probe is off by the alignment offset 257508 - CME does not recognize a change in cylinder 258116 - TESA: VISIO500 : High Mag bounded to 4.5 when offline ----------------------------------------------------------------------------------------------- Version 4.3 Maintenance Release 1 (Additions After Dec 12, 2008) 252135 - Report Window does not update when Print Background Colors is unchecked in Print Setup even after selecting Redraw the Report in the Report Window. 256297 - View Normal and View Perpendicular functions in laser autofeature dialogs do not work 256374 - Can no longer execute double arm Perceptron programs without crashes 256482 - quick fixtures displaying in incorrect locations after part program save and load 257844 - Leader lines do not snap any longer to any of the connection points on the labels 257981 - Want consistent results between V431, V43B, and V44B Auto Circle Hexagon Block 45 degree bore 258139 - Mirror flipping slots angle direction vector. 258609 - Graphics window shows hidden fixture. The fixture appears on the report pages which breaks their reporting 258645 - Cannot select surface using STEP file 258686 - Probe Deflection Issue - Calibration 258716 - T-Probe will not run if using PRO version of PC-DMIS 258726 - printing into rtf file - turkish version - index written twice 255446 - MYCRONA: Edit window (summary mode) shows different values then Auto Element window and edit window (command mode) 257537 - Loading Editor hangs at 78% forever 258342 - when rotating a cad view with a point cloud in it the view will not rotat about the pointcloud like it will with CAD 258689 - Toggling man to dcc the active ptb page changes from Laser Scan Properties to others ( last used one ) 258812 - Viewsets are not retaining the feature and Dim/Point Info label definitions 248854 - RMeas & Snap have always been mutually exclusive ----------------------------------------------------------------------------------------------- Version 4.3 Maintenance Release 2 (Additions After MR1 Release) 104033 Added Circle Plane and Line profile analysis from Scan Constructions 104036 Added CM170 laser as a member of the laser family 105166 Calibrate laser probe to measured sphere position 105170 Added Manual CMM interface 105319 Added Tesastar-m 7.5 Probe to the probe set 105322 Added Renishaw component to probe.dat. 105350 Added support for : S(1_A0.0_B-45.0) = SNSDEF / PROBE, INDEX, POL, -45, 0, 0, 1, 0, 415, 3" 105360 Converted the atached dxf file into a draw model for a tool rack. 105477 Modified CADObjectsSlice() to sort the polylines. 105530 Added a third party DLL to the installer to support multiple device driver 105569 Ability added to turn off the Pro/E DCI error messages when Pro/E is not available. 105955 Added ability to control Ring lamp by the bulb 239137 Incorrect calculation for T vector. 240218 Leapfrog/Relolcation: prompted to move the part "to the new location" after a re-measure 245448 Application Error if mouse click on the Graphics Display Window, following the cancellation of a point. 246135 Using tp from datum to refine datum virtual condition, use lower segment of datum composite tp value 247174 Perimeter scan on a single surface, getting wrong surface vector half way through scan, some points good, some bad 247273 Unhandled exception error after executing an Autocalibrate Command 248029 Slot Position : the bonus tolerence from length and width deviation appears to be wrong 248429 Perimeter scan with Perceptron is choosing questionable tips 248672 Projected tolerance zone in True Position dimension appears to be reversed 248854 RMeas & Snap have always been mutually exclusive 250136 Calibrate the Unit unnecessarily activates the C axis section. 250246 Nominal probe compensation with PROBECOMP/OFF 250248 No hits via CTRL-H in Operator Mode 250749 NIVEL toolbar for SMX? 251376 Can not use Make 3D in v43 252135 Report Window does not update when "Print Background Colors" is unchecked in "Print Setup" even after selecting "Redraw the Report" in the Report Window. 252334 New "Point Cloud" toolbar hammers HASP which causes delays, thus bad stripes on Contour V4i 253182 Iterative repiercing doesn't work for AF points (angle, corner, edge, surface, vector) 253203 Tolerance lines are clipped when not in XY plane. 253467 PAGE() and PAGES() did not work in a Grid Object 253490 Several issues with Using a Temp Comp command in a program which will be run across more than one CMM with different Sensor Numbers for the Part and Axis. 253541 The change of the label inside a FCF inserts two non erasable labels. 253730 FlexDMIS: A lot of the lines in the DMI terminate with strange characters 254086 Laser AFs Test: the dots in the graphical analysis are always green 254125 If CAD AXIS not equal to machine axis in the Setup Options, the view setup shows wrong view 254156 Focus after a focus failure in vision offset cal has no -Z prescan move 254310 Adding an Item (basic script) to the ToolBar to v43RC; Item will not work. 254577 Projection Plane flipping angles on circles 255379 Characters of data grid in Position Dimension exceeds the cell 255410 Auto position is not working correctly on dual arm machines 255539 When the user changes the probe head orientation more than one times the graphics window does not show the new orientation until he closes and re-opens the pp. 255647 "Missing file: C:\43MR1\PCDshellextensions.dll" only the first time that I start the app after installation 255819 When using COP in scan the part program can be used one time only 255842 MYCRONA: PC-DMIS don't remember the current probe when changing to a video probe 256108 Press Cancel during multiFOV autofeature execution ---> Crash Pcdmis 256186 Legacy reports do not allow print if is showed onto the screen 256297 View Normal and View Perpendicular functions in laser autofeature dialogs do not work 256374 Can no longer execute double arm Perceptron programs without crashes 256377 V4.3 will not launch, error referring to msvcr80.dll displayed 256482 quick fixtures displaying in incorrect locations after part program save and load 256524 The dimensioncolorball shows the wrong color in CRO 256534 The Hold button (Analyze Hold) does not work when CNA files are available. 256560 Offline Mode (Program Mode) won't give proper vector 256562 Serious deviation of result of measured points below the theoretical surface. 256599 No highlight of measurement axis for Distance to Target 256612 LEITZ_TABLE.draw and usermachine are not inclding in the installation with the new release 4.3 xxx 256632 Lsp-x3 probe crash since the scanning parameters didn't apply the change 256653 Legact Hyper report will not print to PDF 256714 XYZ location of the constructed line is not correct when re-opening the dialog 256732 Bonus Tolerance Problems 256734 Toggling the field type on a laser circle causes application error 256764 Execution of alignment commands where the reference IDs are missing can cause fatal collisons 256827 Default feature tolerance not working as expected 256852 The construction of a point (Pierce) is produced with two equal features. 256854 When we change the arm environment from arm1 to arm2 and F9 on a feature, the tip is not in the center of the feature (see attached screenshots)." 256897 In 4.2Beta in auto features, the probe would flash for a second and then disappear. This got the probe out of your way after you selected a point. This ability seems now to be gone in 4.2mr2, and 4.3. 256987 The measuring path for Laser AutoSphere is correct only for small spheres 257031 Can't "Clean" PointCloud 257261 There are several inconsistencies for Laser AFs in Summary mode 257343 Feature tests on Arm1 but is created moving Arm2 257377 Optimization Path is created only for Arm1. 257432 No on/off control of manual scanning 257450 The Reference System (XYZ translation) has not been imported. 257562 IW42 probe angles are not verified when changed in the Edit Window 257598 Leapfrog/Relocation: displayed hit target is on next feature during the relocation 257610 TESA: VISIO200 : New I++DLL to fix resolution issue when using collimated light 257694 Hyper reports including CAD window can not be saved without error 257754 SYSTEMS 4 UI : no Station control in Edit Window with Bundle port lock 257787 When you View Path Lines all Basic Scans in the Edit Window (Command Mode) disappear. 257792 PC speaker beeping for no reason during scan 257838 Czech language does not install. The warning - Cannot install files from 'czech.mva' - appears during installation. 257843 PC-DMIS don't ask to load the new probe before qualification 257844 Leader lines do not snap any longer to any of the connection points on the labels 257928 SP25 Quick Cal VB script fails before 2nd probe angle in part program. 257978 The axis graphic color in the label template used for the standard PDCDMIS Cadonly (and CadOnly landscape) report templates doesn't match the setting in Edit-Graphic display window-Dimension colors 257981 Want consistent results between V431, V43B, and V44B Auto Circle Hexagon Block 45 degree bore 258037 Legacy True Position Label shows wrong deviation direction in the ActiveX Object 258199 The wrist of the Arm2 don't rotate during the phase of calibration 258305 Change Manager finds changes that do not exist 258335 A high exposure value at 50 or 60hz will cause a non-descriptive "Hardware Error" and then, toolkit doesn't recover. 258342 when rotating a cad view with a point cloud in it the view will not rotat about the pointcloud like it will with CAD 258344 Location of a Linear Open Scan changes when program is migrated and executed from V4.2 MR1 to V4.3 MR1 RC. 258418 Refined alignment crashes always using the Face option with this program/model 258449 Changing Laser Type does not update Probe Toolbox, or loaded probe type 258460 Applying simple roundness or flatness on a laser scanned feature takes a LONG time 258465 Incomplete PDF file when HyperReport Inline flag from previous versions is then set to ON inside latest. 258468 Switching from V5 to Offset ball pobe does not work in Execution 258472 When editing an Hyper report created on version 3.5 mr1, the leader lines point anywhere and not to the features they are related to 258503 ISO 10360-4 program does not work in versions later than Sep 15 - collision 258511 Nominals for Surface and Edge points are selected on the cloud even if there's a cad model loaded 258513 FS#1248 Files are not correct imported 258517 Page Orientation and Page Size not working properly. 258521 SP25 probe signal sometimes is disabled 258522 The overall flatness does not consistently carry over into the report. 258525 Crash trying to delete a Laser AF after some editing and execution 258526 Change Manager recognizes the change in thickness but does not update the Edit Window 258559 Change Manager does not recognize thickness change in surface 2 258560 Change Manager recognizes a change in depth of circle but does not display it 258567 Prints three blank pages when "Out Of Tolerance Only" and "Use Text Mode Dimension Reporting" options are selected. 258595 Array violation in LK 2000 twin drive code in CompnsatePoint() 258605 PC-DMIS crashes when switching between Auto Features / Strategies. 258608 You can't see or edit any laser parameters in the edit window can't change them as necessary. 258609 Graphics window shows hidden fixture. The fixture appears on the report pages which breaks their reporting 258630 PSL Export doesn't seem to be working right. 258645 Cannot select surface using STEP file 258656 Ipsolve55.dll not found 258657 On a PP, inserting or creating a new fixture which name contains a dot "." in it will make PC-DMIS to create the external alignment (fixture alignment) with the wrong name 258686 Probe Deflection Issue - Calibration 258689 Toggling man to dcc the active ptb page changes from Laser Scan Properties to others ( last used one ) 258693 Cannot ReExecute a Laser Scanned Program 258716 T-Probe will not run if using PRO version of PC-DMIS 258717 Nominal option does not work for File | Export | XYZ 258718 When use exact dimension for cylindricity and ask for graph reporting the cylinder is drawn the incorrect size some times see example program 258726 printing into RTF file - turkish version - index written twice 258730 When I try to execute this program with the BASIC script in front, I get an unexplainable error. 258756 Middle Line and Middle Plane have inverted vector from v3.7 to v4.3 258762 Feature Sets not updating on execution when they contain assignments... 258765 Legacy Tp reporting Both ends of axis, wrong tol applied to end point 258766 Don't generate legacy tp DF axis if Auto not selected, feature is at RFS, and registry setting says no DF 258774 v43mr1 program executes in v42mr2 will make probe crash since the autoline definition 258775 Can no longer expand location for looped features 258777 The reporting is broken in 42MR2 - Feature now appears in the report even if they are switched off from the related registry keys. 258778 When they execute a feature online the probe head jump 3 times from the end of the arm to another place on the machine and then come back. 258783 When they execute pps in PC-DMIS 42MR2 online or offline they frequently get the application crashing after 5-6 executions 258793 v4.2 to v4.3 migration: "-01" added to file name in PRINT command 258796 Layout errors in Chinese Resource 258804 Selecting small features in CAD using Profile 2D 258809 I get an error indicating "DLL Failed to Load interfac.dll". 258812 Viewsets are not retaining the feature and Dim/Point Info label definitions. 258813 Strange CRO issue when we have 2 CRO on page & re-edit the feature based layout 258814 Auto Features use all data in the COP, even if unselected 258818 "Unable to register Dll: contour05.dll. File not found" at the end of the install 258820 Unable to load strings: ES_LASER_FILTER_CM170_TOGGLE (other failures will be ingored) 258837 When using Edge point with Theo Thkness, after edge point is selected offsets applied, if you select SWAP then nominals should change to reflect thickness." 258848 Problems when adding or editing a plane as Calibration tool. 258861 SYSTEMS 4 UI : Leitz Stylus is wrong defined 258863 Prog size is still the same after empty and purge cloud 258893 258893 - The image of the part in the section cuts is not visible any longer - SCRO 258894 Getting message "Machine not responding" 258902 Fix .NET 2005 Migration problems from 10/30/06 which results in a crash 258906 Pc-dmis crashed when exporting with IGES Chinese feature labels 258907 Pc-dmis crashed when importing STEP file 258925 When I try to re-calculate the flatness dimension, I get an application error. 258933 Nominals for dimesions change when migrating existing programs to 4.2 MR2 258942 When I try to create a Basic Line Scan, nothing happens. 258944 Penelope putting PC-DMIS "INDENT" number for GAP features in DSURF field. 258945 Straightness analysis shows bad data, but the dialog window does not update actual dimension 258963 CAD won't face colormap 258982 Probe missed part when running collision detection 258987 Assembly tree did not show the names 258992 After "execute block" is finished, everything that wasn't part of the block becomes un-marked 259006 Learned cyinder can't be execute correctly in Dcc mode 259012 Sensor Hardware Error with a contact probe loaded... 259014 Unable to take calibration stripes with CMS 259019 application error from laser AutoFeature and empty COP 259023 DES: Trouble working with DES file and new AF's 259033 Wrong import CAD model of PP from v3.7 after import to v 4.2 or 4.3 259066 Problem with Grid Object in Standard Template, in Version 4.2MR2Release and 4.3MR1Release, also in 4.3MR2RC 259096 Location Dimension not updating 259110 Clearplane command seems to be ignoring the current tip angle... 259114 Pass through Clearance plane behavior has changed between 4.2 MR1 and 4.3 MR1... 259115 UG DCI license signing is failing on the build systems.... 259136 Crash inserting a Purge command in the EW via toolbar 259138 Editing an AF and changing the Sensitivity mode associated to that AF the new value is not retained 259143 Add Wildfire4 support 259145 LiveView in double arm no longer works 259150 Incorrect Nominals after editing circles via right click in summary view edit wiindow and F9 (or choosing edit) 259183 Please remove the AutoExposure button from the LiveView... 259190 Wrong Dimension colorball in CRO, if the report has more than 1 CRO 259200 UseWristMapIfAvailable checkbox must not be exposed when creating CMS probes 259209 COP shows up in cad report object 259211 Point Deviation is incorrect after alignment 259217 CAST and variables do not match location of SNAP point with RMEAS 259238 Feature analysis: points remains in the GW until the dialog is closed, and they're black instead of colored 259240 ReadPosition fails from a cold start 259243 Wrong design for tesastar_rp 259263 Programs with custom report crash. Work in V4.3R 259270 When they open the attached pp some of the IF/END_IF commands are not linked to each other 259285 The GBAR is not getting copied over during the install. 259289 The "DataPort" field of Arm1 is not grayed out when Pc-Dmis is set to be an Arm2 259313 DES: EdgePoint Surface Vector not from imported file 259316 Cad Vectors and Back Face Culling disagree 259317 Adding multiple cad files and then merging the assembly is missing the names of the subsequently merged files 259324 cmd = cmds.FindByUniqueID(locCmd.Hi, locCmd.Lo) is broken 259340 Creating an auto notch slot through the dialogs is giving an application error 259352 Export large pointcloud as IGES crahses PC-DMIS 259354 Reseting Pointcloud Crashes PC-DMIS 259367 Penelope: add to the end of the file the number of warnings in the file 259413 Arrows are not perpendicular to the CAD 259420 Switching to the offset (hard) probe from the laser causes points to not be recorded. 259424 Resetting a Face cmap, some surfaces ( always the same at each try ) remains black 259432 Some Point Deviations are incorrect 259440 WAIToolkit.dll in wrong location causes application error when the installer launches PC-DMIS the first time. 259444 Pc-Dmis is unresponsive and hangs for life with the hourglass in case of a CmsKit error 259460 Rotary table animation. 259461 Assembly tree view is different from v41 to 4.3 mr2 259474 Some time the LiveView hangs 259481 CMMOS Interface still not building in any version 259488 Alignments not updating 259493 Setting to draw leadline for Dim Infos in customreport is not saved 259496 Copying and pasting IF/END_IF control pairs sometimes rusults in an application error when quitting a part program 259521 Dim Info Labels Not attached To Model 259527 CME does not update all selected changes 259529 Penelope: Some features are output incorrectly 259531 PC-DMIS aborts when using Penelope to export attached part program 259534 Has anyone noticed that PC-DMIS Clearance Planes are not working correctly? 259535 Switching on the LiveView it shows active but completely empty 259536 PC-DMIS crashes trying to open the attached part program... 259560 WildFire DLL will not load... 259588 Wrong distance for two lines when executing part program with Romer different workingplane then ZPLUS 259591 Graphics window draws empty when it gets the focus. 259617 Application error when I open the attached pp in 432. It opens well in 431R. 259623 Tracefield screen is not ready for input to be typed in 259626 Readout window showing hits when opening auto feature dialog 259631 Can't right click any items in the edit window in summary mode. 259632 Need a way to disable the LockExpiryReminder dialog. 259633 Importing a VDA file containing points will generate a CAD file with curves but no points 259635 Mid line is incorrect in the attached part program. 259674 Can edit ACTUAL values on VISION auto features 259716 Perimeter scan doesn't work: after programming the scan, instead of just scanning or ask for calibrated tips it sits there with the hourglass and only taskmgr helps 259717 TextOnly Report and Edit window shows different automotive letters 259719 Pcdlrn crashes when dimensioning begins on constructed planes if FCFs are replaced with legacy dimensions 259722 Cannot Create Distance between Circle and Plane from QS 259725 Problems with scan shark laser CW42 C joint and probe changing 259733 They can't maintain their existing HRs in 432 because the label properties are disabled. 259754 Defined Path scanning problems for Laser and Tactile particularily Freeform. Wrong density, bad path 259768 Can not calculate 2D Angle in PCDMIS 4.2 MR1,2 259770 Starting a new program with the Serein 'premium' config, the probe calibration dialogue does not come up, and you cannot F9 it either 259790 For graphical analysis report "Remove Object Modification" option can not affect the mutiplier number, and also pcmdis crashes when clicking the "Remove Object Modification" option again 259799 Wrong tip proposed to measure a Cylinder 259828 Reference 22.12.9 Model Z zero position is incorrect. 259854 In some of their pps the Safety Plane button in the auto features is disabled. 259860 Dimension decimal of FCF can't follow the default decimal value of F5 setting 259870 Perceptron - PCDMIS is crashing during calculation of facecolormap 259872 Scan path is generated only partially for a Patch scan with 18 boundary points 259873 Program mode feature programming generates unexpected "Move commands outside travel limits" error warning 259891 The positive reporting is broken in 432 259897 Inserting more than 1 FCR Animating probe rack is not allowed. However ycan insert several ACR3' 259909 pcdmis crash while executing a program in Operator Mode 259921 "Calibrate the unit" does not work for CW43 259951 Image of the profile in the SCRO disappears during the pp execution 259969 The automotive letter on the Y axis of the dimensions always stays on O independent from the direction of the deviation. 260010 Can not input 0.0 for positional tolerance in FCF of true position 260021 COP not recognized as feature for Probe Change 260022 Scanned points not transformed by LeapFrog 260025 NCSensor related crash when cancelling calibration of non-NCSensor probes 260036 PCDMIS crash, if one pro-E CAD is imported 260046 After doing a sphere calibration, execution hangs on ring calibration, cancelling creates code for ring calibration 260054 Need to close and reopen the program to get MEAS updating in Summary Mode 260065 When I add nominals for the location dimension of a round slot it changes the measured values also 260066 ASSERT & nothing in edit window 260081 pcdmis crash when I import the .des file as description 260088 Laser Live Views are opposite making it difficult to switch between the two 260122 Profile Report Labels Point to Nothing 260126 Not all Pages of Custom Report is printed to PDF 260148 Default.ipd should have defaults for auto plane modified 260156 All lines go to the same point not to the element (customise reporting) 260159 ISO View is showing wrong Z direction after Part Setup 260167 Form will be printed even the AUTOPRINT=No 260173 Can't create a face colormap if I change the cloud color 260174 Creating a face colormap, the hidden Cop is back in the GW 260181 Application is crashing when refreshing the report window 260184 The complete CAD image is darkened in the graphics window 260201 Pixel Locator settings are set to "empty" on start of PC-DMIS 260211 Can't view pathlines with this program 260215 Application is crashing when they open the attached part program 260232 Correct issues with the CATIA v5 sample part model 260238 Portable Laser Execution: Alignment Cad Selection: Slots not working 260240 Portable Laser Execution: unmeasured features not highlighted 260249 The Arm2 machine is moving unexpected - Application is later crashing when the pp quits or closes 260253 All arm2 auto features of any 37 pp toggles the thickness type from ACTL to NONE when the pp gets loaded in 432 260254 Form graphic contains weird lines, lines LINES! Circularity, straightness what else? GRAPH=ON dimension 260255 Application Error if I click on the Edit Window, when an Autofeature dialog is open. 260276 The execution dual arm (multiple arm mode) doesent start using automation 260279 DMIS Import Error - some constructed features are imported as comments 260296 Application crashes if we open an existing part program 260300 Scanned COP's not being handled nicely during execution (for non-portable laser exeuction case) 260303 Patch scan, there's data acquisition even when it should not 260308 No graphical analysis for Runout 260324 Application error in the Delete CAD-Elements operation 260341 Autofeature extracted from COP use autoPH9 feature 260342 Autofeature extracted from COP sends tool rotation update to controller 260344 Autofeatures extracted from COPS - Circles and Slots take WAY too long 260383 Pc-dmis v44 FIT can't complete the installation since the SPCmonitorctrl.ocx missing problem 260398 Can't see or edit overscan value or "ring band" enabled in edit window for Autofeature using COP 260402 Probe file affects ability to properly import ip file 260414 They get an Error Message when execute custom reports: "an invalid Argument was encountered" 260426 When they close and open the pp the LOAD/MACHINE command have moved to a different location 260427 CAD info windows does not show the Lenght of a curve (Thickness Vector) 260439 Lighting values in the live view do not match the probe toolbox during calibration 260440 Un-Calibrate Pixel Size is a bit silly 260441 Focus target when using the focus tab is always 1" above the field of view. 260444 Any program with a point cloud will not save, or open without SERIALIZATION: Pointcloud Error 260448 Whenever focus fails a new file is being created in the program directory 260477 Pcmdis crash when i want to do some change to the attached partprogram's alignment 260515 Using numeric string formatting command FORMAT(arg1,arg2) causes crash during editing. 260521 Show Previously Unused Labels function is not working correct 260523 Opening the Collision Detection dialog results in an application error 260545 When import xaml file exported from cad file, it is shown black. 260551 If add Tempcomp in program CNCSERVER can not process data ok only got a cnp file 260557 Opening an existing prg with Catia DCI V4 result in crash after rotating the model. 260560 Overscan and Row Overlap initialized at bad values, machine does not move testing features 260564 Testing the same feature multiple times, the wrist is rotated without reason before each attempt 260589 Edit true position FCF (F9), change secondary datum C to MMC, press OK, PC-DMIS crashes 260593 Setting the TrackerName property in the settings editor doesn't work. 260597 Dimension Color Key is inverted Not like in 4.2. 260606 Buttons in QuickStart overlapping in Serein (V432).... 260608 When open the attached partprogram build in 43 , "encountered an improper argument" message appeared when show report with CADonly mode 260618 Feature_Tracker.lbl: time stamp is so small that it is not readable 260639 CMS Portable: Calibration yellow guide lines in Live View are incorrect 260643 Part programs that include ADJUST FILTER commands are not compatible - Software crashes 260649 CMS Portable: CheckVoxalization Assert/Crash during scanning 260651 CMS Portable: Autofeatures allowing COP to use 'Disabled' when that isn't possible with manual AF's anymore 260655 When they mirror the reports the labels in 1 of the 2 CRO does not mirror. 260664 CATIA v5 DCI does not handle assembly instances 260666 CMS Portable: Not entering into Portable Execution 260686 CMS Portable: Disable sphere calibration... we only use plane calibration 260697 I'm not able any longer to import an EXPORT.IP file that I created from the update part program manager 260711 Syntax error in the machine.dat file at the tablecenter line for machine "GLOBAL_B&S_5-7-5" 260727 PC-DMIS install is missing redistributables 260734 The LoadReportTemplate Method doesn't return 0 (True) or 1 (False) 260751 Quick start best-fit fails - error on A1 260755 ANALYSISVIEW Commands display the wrong view when migrating programs from: 4.2MR1 to: 4.2MR2, 4.2MR3, 4.3 and 4.3MR1 260757 If a deviation is 0.0 mm, the colourball of Report has the wrong colour. A OOT Colour by a Tolerance of +/- 0.5 mm 260758 Invalid Number entered and Carry Nominals back to feature Warnings appear (2x) when enter the minus tolerance for a diameter for Legacy True Position from the Edit Window 260773 Application Error if I press OK button when "No Machine" is selected. 260775 All holes (circle, slots) have strange moves: Before the 1st sample hit the machine moves at a point about 1m off from the feature (out of tolerance) ... 260786 T-Value on location dimension is wrong 260807 Sphere diameter not drawn in CAD View correctly - measured value also seems wrong 260814 Unable to use a surface after mirror CAD 260817 Planner can't open .cad file it creates 260819 Out of Memory during the use of an AutoFeature (Angle Point or Corner Point). 260828 Change manager does not update changes on the RT axis on a location dimensions 260831 Unable to select a hole 260833 The optimize path operation is broken in 432 and 44. 260850 The DMIS export of auto features with ACTL thickness is incorrect. 260869 No CAD displayed when opening part program 260876 Probe compensation wrong - randomly on defined open linear scan 260934 CMS: Beep Volume doesn't change until you go into the 'Laser Scan Properties' page of the PTB 260976 MYCRONA: PCDMIS doesn't save the Find Surface setting in the pp 261000 Incorrect measurement of square-slots in version 4.3 261003 Pc-dmis crashes on loading any CAD report with updated program from earlier version. 261007 Autofocus - Works Incorrectly 261027 A bunch of XML files generated on the Desktop while calibrating 261028 Crash during portable CMS calibration 261031 Point cloud Operator Cop coper : Color Facemap crashes PC-DMIS application error or works really too slow 261061 Unable to set Vector with SetRotabData assignment 261084 Cross section of part shows extreme deviation. Arrow bigger than part 261085 Wireframe model in DP+ has fewer lines than in pc-dmis. Information is not enough. 261097 Probe is drawing incorrectly when building in the Probe Utilities window 261117 PC-DMIS Section Scan will crash the CMM when tested on the Global Leitz CMM. 261125 Icons missing in Serein for the View Setup dialog.... 261144 Nominal field in Angle Between dialog seems to be random from migrated part programs... 261151 Install creates a pcdlrn.exe with a file size of 0 which of course crashes on startup... 261178 Bad RMEAS execution in 4.3MR2 version (compared with 3.7) 261180 Part not shown correctly after alignment from Qucik Start 261182 Problem with PCDmis reports when saving from V4.3 to V3.7 261186 The Version Number doesn't appear for the V4.3MR2 261189 Pointonly mode and find nominal from cad doesnt' works fine in manual mode 261245 Program hangs PC-DMIS lock up at around 70% 261259 Adding alignment in above feature, answering NO to update commands, commands still updating 261260 Reported straightness wrong from a constructed 2D BF line 261263 T-Value is calculated wrong, if dimension is insert under another alignment like point was measured 261295 Bestfit Alignment does not work after program has been re-opened 261364 Vectors flipped scanning part 261380 The laser is not on during the probe offset procedure, nor can you turn it on once started 261394 PC-DMIS locks up on second auto circle feature measured every time, but only when CAD is present (CATIA DCT) 261398 After programming the part with cad then running the part in simulation the cad relation ship is lost to the measure features 261415 Form dimensions of features constructed from pointclouds causing Application Error 261419 Pointcloud operators hang execution 261428 Protokoll head (Hyperreport) is not shown. 3.7 mr2 to 4.3 mr2 261430 If quick fixture alignment in pp, dim info and max/min labels aren't connected to the analysis in the analysis view 261448 can not show all the machines in the machine como box if machine number is more than 11 261468 No path line generated for basic scans from last feature to beginning of scan. 261525 Auto line not solving correctly in case included in this file 261528 The 'Execution dialog' opens during the optimize path operation 261533 PC-DMIS crashes if importing attached iges file 261534 DimInfos do not update as expected if dimension changes 261539 Location dimension shows wrong MEAS value on BFRE plane constructed using auto vector points 261557 2D distance plane1 to plane2 perpto plane2 gives incorrect MAX, MIN values 261571 Crash in reporting 261587 Message: "Nominals Update: Do you want to update measured values also." arises during IP-Import 261592 BestFit results: Max Iterations 100, Iterations 101 and high standard deviation/mean values 261593 When scanning getting Find Nominal Tolerance error 261598 When using a Best Fit alignment, profile dimensioning will cause Pcdmis crash. 261603 PPAP Header has bad character in it 261607 Section scans on interior small radius, if thickness is added, are not created properly 261608 Display the hits from an already measured scan makes PC-DMIS delete the Measured Data 261619 When a plan is imported into PC-DMIS that includes symmetry, no dimension statement is created. 261623 Translation Error in Resource.RC and String.RC 261721 During the Path Optimization, the system is crashing. 261753 Polar angle didn't give the correct values when the angle is greater than 90 degree 261773 Bonus and DF options of TP can't be removed in the old style reporting when I use FCF mode 261776 ScanShark definition in Probe.dat doesn't match the sensor geometry: this is causing problems on various machines 261777 Hybrid grid volcomp is not being applied 261851 Autofeature Square Slot Laser measurment - movement is perpendicular to laser stripe. It should move along the slot angle vector. 261864 Auto feature line has a problem when dragging the left most grapchical hit. 261866 Problem with import of a 2D angle through DMIS 261879 Active alignment after hyper report is wrong - probe crashes 261908 The manual iterative alignment is broken 261929 The report head in legacy report isn't shown. 3.7 mr2 to 4.3 mr2 261939 animated toolchanger needs to animate move to safe location 261988 CAD Transform 262023 After path optimize the edit window is missing features, summary mode only 262040 PPAP reporting give the incorrect result in v43mr1 262045 Basic Scans don't add CLEARPLANE commands 262101 Printing to PDF causes label lines to point to wrong area. Graphics Refreshes when program closed and reopened. (TKA Issue) 262108 Profile of Line dimension on COPOPER (laser data) crash PC-DMIS Application error 262117 Problem with Profile dimension - wrong answers, from COPOPER CROSSECTION Laser data 262173 Some features are being skipped during Collision Detection... 262175 Probe colliding with part but path lines do not show as red... 262184 Graphical analysis view is not correct after part program run 262267 When I create a section cut on some of the surfaces the vector of the hits reverses. 262385 Freeform scan crashes SEVERLY into part in middle of scan. 262386 One of the both leader lines on the distance labels is missing in the custom commands when they convert it from a hyper report. 262445 When I re-measure the same sphere with calibrated SP25 probes, the location values are showing large deviations. 262447 XY data has an error when the Z is below the bottom gird position for 2 level calibrations 262522 Qual Tool Material Coefficient units are not being converted as all other axis... 262531 Appears that graphic probe behavior got changed with kinematic engine when creating autofeatures. 262575 FCF profile doesn't divide tol equally between +tol and -tol when GDT Standard is ISO 1101 262734 Distance to Target red lines are no longer functioning as in 4.2 MR2. ****************************************************************************************************** ******************************************************************************************************