----------------------------------------------------------------------- Wilcox Associates, Inc. PC-DMIS® Version 4.3 Enterprise Metrology Solutions Installation Notes: ----------------------------------------------------------------------- 1) General System Requirements 2) Information about this release 3) Beta Test Site Agreement Form 4) New Product Information 5) Release Notes **************************************************************************** **************************************************************************** 1) General System Requirements Minimum Requirements:------------------------------------------------------ | | | • PC-DMIS® 4.3 operates under 32-bit and 64-bit (x64) WindowsXP® systems | | and 32-bit Vista Business®. No other operating systems are supported. | | • Pentium-IV or higher processor is suggested. | | • 1 GHZ or higher Intel processor. | | • 1GB of RAM is recommended but significantly more may be required if | | working with large CAD models. | | • 500MB of free hard drive space minimum for the application. | | • SVGA capable monitor. | | • CD-ROM drive. | | • USB port available. | | • The computer must have a graphics card that supports OpenGL shading. | | We cannot specify an exact graphics card since every user has varying | | needs. However, nVidia is the preferred graphics vendor for PC-DMIS. | | • Nvidia GeForce video cards are not recommended for use with PC-DMIS. | | This is defined as a "gaming" card according to Nvidia Engineering. | | • Supports a screen resolution of 1280 x 1024 or higher. | | • RTF file output requires Microsoft Word to be viewed. | | • Microsoft® .NET 2.0 | | | -------------------------------------------------------------------------- Recommended Minimums:------------------------------------------------------ | | | • WindowsXP® 32-bit or 64-bit and 32-bit Vista Business® operating | | systems. | | • 2 GHZ or higher Intel processor for improved performance. | | • 2GB of RAM or higher. More RAM may be required if working with large | | CAD models. You should have RAM equal to 8 times the size of the | | largest CAD file you will use. (For example, if you use an IGES model | | of 250 MB, then 2 GB RAM is recommended.) | | • 1GB of free hard drive space plus allocated Virtual Memory of 8 times | | the largest CAD file used. | | • SVGA graphics card that supports OpenGL shading and that has WHQL | | certified drivers. On board video card memory should be based on the | | size of CAD file being used. | | • For small CAD files (less than 50 MB), 32MB video memory. | | • For medium CAD files (50-100 MB), 64MB video memory. | | • For large CAD files (> 100 MB), 128MB+ video memory. | | WHQL (Microsoft Windows Hardware Quality Labs) video drivers can be | | downloaded automatically when using the Windows Update software. | | • SVGA capable monitor. | | • CD-ROM drive. | | • 2 USB ports available. | | | -------------------------------------------------------------------------- • NOTE: Depending on your specific needs, the recommended system specifications for this version of PC-DMIS may be much higher. A more substantial computer system may be required to accommodate part programs using Automation or complex Reporting objects. Be sure to consult with your PC-DMIS distributor to find out the type of computer system you will need in order to run this software at its optimum capability. • IMPORTANT: When using 3rd-party drivers you should contact your local Hexagon representative to ensure Operating Sytem compatibility. • ANTI-VIRUS SOFTWARE: The Sophos® Anti-virus tool was used by Wilcox Associates Inc. while testing PC-DMIS. The performance of any other anti-virus tool will need to be confirmed by the user. (http://sophos.com/products/enterprise/endpoint/security-and-control/) **************************************************************************** **************************************************************************** 2) Information about this release. We at Wilcox Associates are proud to bring you this new version of PC-DMIS® 4.3. This Enterprise Metrology Solutions platform brings together new aspects of PC-DMIS® for the development of a complete manufacturing process control solution. Available in this release are variations of PC-DMIS® designed to assist with every aspect of the fabrication and quality control process. The newly created packages include PC-DMIS® Laser, PC-DMIS® NC, as well as the established PC-DMIS® Pro, PC-DMIS® CAD, and PC-DMIS® CAD++ platforms. Also included with this release is PC-DMIS® ONE, a simplified shop-floor DCC inspection package developed in cooperation with Brown & Sharpe. The testing of this version has been significant. We’d like to take a moment to discuss this process and also make you aware of the various components of testing. Testing is comprised of two parts. These can be described as functional testing and integration testing. The vast majority of testing effort goes on in the functional area. This is the testing that determines that specific functions that are core to the software, regardless of what type of machine is used, are working correctly. The integration testing is essentially a testing of the interface with a particular type of machine. In the ideal scenario, WAI would have access to at least one of every piece of hardware that is operating in the field running PC-DMIS®. However, in practical terms, this is impossible. This integration test plan is then performed on as many types of machines as we have available. Unfortunately, there will inevitably be machines to which we do not have access and that cannot be fully tested in this manner. To this end we have made an effort at closing this gap by partnering with our customers through the Beta Test Program. On the following pages you will find an application for this program. We urge you to consider signing up for the program as it provides the mutual benefit of helping us create the best product possible for you, our customer. Should you experience problems with your system after installation of PC-DMIS® 4.3, it could possibly be an integration problem. If it is a problem of this nature, it will probably be evident immediately upon first use of the possibly untested configuration. Should such a problem materialize, you will be given the highest priority for correcting these problems. Please call Tech Support immediately to report any integration problems. For existing users of PC-DMIS who currently have earlier versions of PC-DMIS® installed, it is advised that PC-DMIS 4.3® be installed into a new directory. In this way, you can be assured of continuous use of the existing version should problems arise with this newer version. **************************************************************************** **************************************************************************** 3) Beta Test Site Agreement Form As part of our ongoing efforts to improve the quality and ease of use of PC-DMIS®, we would like to actively involve our key customers in the development cycle. There are several advantages of being involved in the PC-DMIS® Beta Test Site Program. You will: • Preview cutting-edge PC-DMIS software enhancements • Provide direct input into the development of PC-DMIS • Receive a 25% discount on one PC-DMIS Software Maintenance Agreement (SMA)* To qualify for this program, you must meet and agree to the following requirements: • Have a machine/interface type required by WAI/Brown & Sharpe Manufacturing Company for testing purposes • Be willing and able to download and run Beta versions of PC-DMIS® • Be willing and able to perform specific tests as required by WAI/ Brown & Sharpe Manufacturing Company when necessary. These tests must be performed as outlined and within a mutually agreed upon, reasonable time frame. ________________________________________ _________________________________________ Company Name Contact Name ________________________________________ _________________________________________ Address1 Address2 ________________________________________ _________________________________________ City, State, Zip Phone ________________________________________ _________________________________________ E-mail Address Fax SMA Expiration ___________________ CMM Type ____________________________________________ Manual/DCC __________________________________________ CMM Serial # ________________________________________ Controller Type _____________________________________ Portlock # __________________________________________ Interface Type ______________________________________ Operating System ____________________________________ I have read the PC-DMIS Beta Test Site Program Agreement and agree to all terms stipulated: ________________________________________ _________________________________________ Company Name WAI / Brown & Sharpe Mfg. Company ________________________________________ _________________________________________ Company Representative Name Representative Name _________________ ___________________ Date Date *If any of the terms of this agreement are not met by either party, this agreement will become null and void and any discounts will be immediately revoked by WAI/Brown & Sharpe Manufacturing Company. All technical correspondence should be directed to Tim Wernicke of WAI via E-mail or telephone (262) 338-0887 Please mail, e-mail or Fax this completed form to: Tim Wernicke Wilcox Associates, Inc. 932 Tower Lane West Bend, WI 53090 Phone (262)338-0887 Fax (262)338-8006 e-mail twernicke@wilcoxassoc.com ****************************************************************************************************** ****************************************************************************************************** 4) New Product Information (Note: EMS products remain in Early Adopter stage until formal release of each is announced.) • WAI Toolkit - Allows for the creation of custom commands in PC-DMIS ---------------------------------------Major Enhancements--------------------------------------------- >>>Auto Features<<< • Circular moves for a Plane feature • Allow insertion of MOVE/CLEARPLANE or Stored Moves in between AutoFeature hit basics. • Ability to have Gap Only on by default • New "Read Vector from Machine" button for all features >>>Dimensioning<<< • Selecting the "Auto" option in the Location Dimension dialog box, will indicate the automatic choices with greyed out checkboxes (503994). • New dimension for Length of spline (503736) • New True Position In-Between (503412) • Support for 'A' Axes and Angle Point Feature (502897) >>>Direct CAD Interfaces<<< • Allow multiple file selection for UG DCI import (503159) • DCI connection status indicator (500841) • Replace UG translator libraries with improved libraries (503894) • Replace Pro/E translator libraries with improved libraries (503895) • Replace Catia translator libraries with improved libraries (503896) • Replace Parasolid translator libraries with improved libraries (503900) >>>Graphics Display<<< • CAD Info dialog allows you to show the distance between 2 features • Toolbar button to toggle the display of transparency • Display Symbols dialog box - allows you to alter parameters for display elements (radius,size, etc.) • Option to Auto Arrange Labels CAD Window Label (503743) • Hide labels during rotation (503741) • Tooltips functionality for features in the graphics display window • Animation for rotary tables • Collision detection function displays a dialog that tells you where the collision occurred • Features move on machine with fixture movement (503207) • Ability to show all features visible in view (503867) • Speed up path animation (503918) • Collision detection displayed dialog with list of collisions (503980) • Construct point from intersection of scan segment and plane or line >>>Inspection Planner<<< • Path Optimization accounts for the machine volume (503317) • IPD defaults – one thickness value for all features (503378) • Assembly Support (503577) • Remember last 10 tolerances for use in dimension dialogs (503630) • Support for 321 alignment (503731) • Double click on feature in tree view to edit (502733) • Add point density option for 3D scans (503816) • Enhance IP defaults file to support app PC-DMIS measurement methods (503899) >>>Languages<<< • PC-DMIS now supports the following additional languages: Polish, Russian, and Turkish >>>Laser<<< • Density filter to limit data in a laser stripe • Ability to scan points in learn mode from an arm or laser tracker • Sound events added to play wav files for events (mostly laser events) • Real time shading of laser scanned data (503376) • Ability to extract measurement data from laser scans for laser autofeatures • Laser Autofeatures now show measured stripe data in CAD • Greysum material list with associated min and max pixel intensity values • New Cylinder Laser Auto Feature >>>Portable<<< • Ability to indicate if they are building or inspecting to points • Measured points display location for all axes. • Hidden Point construction capability • The Probe Readouts window can report the current feature based on the location of the probe/reflector when executing • Allow the user to control if the data is displayed as probe compensated or not • Color the deviations in the probe readout window according to the dimension tolerance color • Stable point probing for Leica trackers • Alignment that allows the user to specify which axes of the input feature to use during the alignment • Edge Point Mode allows for walk-up measurement of sheet metal features without using the auto features dialog box. • Auto-Inspect mode: Provides automated inspection of a sequence of points using a Leica tracker. >>>Probes<<< • SP25 Probes use a new and improved algorithm in the CoScanning.dll file rather than the older CALRSP.dll. • TRAX or PMM calibration type for Leitz machines in Probe Calibration dlg • Disk Styli are now supported with the SP25 probe • A simplified partial calibration procedure is now available for an SP25 that has been fully calibrated at least once • The LSP-X1 family of analog scanning probes are now supported • Display inactive tool tips in “disabled” color (503811) >>>Reporting<<< • Automation - New properties of a Report and Section that can be set by Automation (ER #502959) • Ability to report if a feature has been skipped during execution • Color ball on Label Layout Wizard should be able to show dim color for selected range of axes (ER #503646) • When editing CAD in the Report Window, the mouse's scroll wheel can zoom like in Graphics Window (ER #503025) • Show dimension labels for point cloud on report (ER #503373) • AudiDraw Converter - PLT(HPGL) file generation (ER #503632) • Ability to control the size of text in grid control object (ER#503828) • AUDI WBZ: Ability to scale the section cut object (ER#503856) • Transparency for the grid object control (ER#503830) • New report expression functions allowing the user to see the report-level OOT statistics (ER #504154) • New dat file control (EH#504269) • AudiDraw Converter - PPM file generation (ER #503632) • WEBASTO Utting: Duplicate page method to custom reporting (ER#504226) • AudiDraw Converter - New advanced property, Wireframe, for CadReportObject (ER #503632) • AUDIWZB: Shaded/unshaded as property to the CRO (ER#504282) • AudiDraw Converter - Show CAD layer on the CadReportingObject (ER #503632) • AudiDraw Converter - Mirror the CadReportingObject (ER #503632) • AudiDraw Converter - Make Leader Lines terminate at two features for distance and angle on CadReportObject of Custom Report • Ability to edit leader lines on the report (ER#502833) • Webasto-Schierling: In the DimensionColorKey object you can change the properties font and font size (ER#504381) • AudiDraw Converter - Expose objects on Custom Report (ER #503632) • Ability to re-order pages on Report Window (ER#503397) >>>Vision Measurements<<< • New Polygon, Notch, and Ellipse Vision Auto Features • Auto Feature Guess mode for Vision • Quick Start support for Vision • Full Scannings Support for contact and laser probes • Speed Improvements in Edge Detection • Speed Improvements in Focus • Selective Sampling (e.g. measure 30% of feature) for speed • Auto sensing for focus to only do a focus when the edge is blurred (CAD++) • Gage arcs draw as arcs, not full circles • Protractor Gage length can be changed without changing angle • Auto Feature button to adjust surface vector to current probe vector ( <--- this could be in the general auto feature section) >>>Vision Live View<<< • More quick access toolbar buttons (Snap To Edge, AutoShutter On/Off, Compass On/Off, Show Target) • More user control over when AutoShutter and Compass features are used • Easy access on right click menu to quickly edit or move to nearest 10 programmed features • More edge detection parameters can be set from right click menu >>>Vision Illumination<<< • Intensity value for current mouse position shown on live view overlay • SensiLight auto illumination adjustment prior to edge detection • Option to switch off illumination on vision machines at end of execution • Option to restore illumination to previous settings at pc-dmis startup >>>Vision Hardware<<< • TESA VISIO 500 support • Add functionality to optionally use a projected grid during focus • Temp Comp added for Vision machines that support this (Visio 500 & Mycrona) • Added support for VISIO 300 red LED ring light • Stacked Rotary Table Support • Dual Camera Support • Matrox Solios support • Matrox MIL8 imaging library support >>>Misc<<< • Export XYZ option • Save As allows to save the CAD file as reference • Ability to export alignment information to a GDS file • Export to Excel Spreadsheet • New Dimension Color window • Probe Readout Setup dialog box as many new features to control the display on the Probe Readout window. • UMESS Translator • MeasureMax Translator • Propose default name for viewsets (503400) ****************************************************************************************************** ****************************************************************************************************** 5) Release Notes Version 4.3 of PC-DMIS is a significant development release of the software. Initial Release Date: June, 2005. **** Prior to the release of Version 4.3, Version 4.2 MR1 was last official release of PC-DMIS by Wilcox Associates, Inc. and the Brown & Sharpe Metrology Group of Hexagon Metrology. Notice: PC-DMIS Database support for Microsoft Access does not exist in Version 4.3 ---------------------------------------Miscellaneous Enhancements--------------------------------------------- 239830 - Turn different scales back on the rulers in the report template editors Known corrections and improvements from Versions 3.7, 3.7 MR3, 4.0, 4.1, 4.2 and 4.2 MR1 that have been resolved: 211323 - Add RMeas to all Autofeatures 222393 - Cannot open SW DCI program to view CAD and PRG if solidworks is not available 230345 - Problem with "Automatic Label Positioning" to be on by default 230692 - Hidden elements show up as already deleted in the Delete CAD dialog box. 233714 - Measured Plane: Location reporting different Z location and large flatness value when measured with multiple tip radii 235617 - AutoRoundSlot: FindNoms mode not solving correctly when in Curve Select Mode (Online Leitz) 235934 - Spherical boundary conditions with scans do not stop with changes to radius or # of passes but always terminate scans at the center point of the boundary location. 236272 - Automation/Reporting: Bitmap property of Bitmap object prompts for file when property is set 236292 - The command "DmisParts.Add" opens a file (*.PRG) without a name. 237074 - Serialization error: No error occurred / the application crashes when shading the model 237841 - Check speed should be set to >0 for a DCC Vision machine 238465 - When executing a part program, hitting the ESC on the keyboard does not stop execution 238602 - application error when changing FCF dialog tab selection after viewing nominal values 238621 - The CAD model of the wrist is partially hidden or it disappears 238653 - Single entity selection ignores Edit/Delete CAD dialog 238978 - AutoCircle: PC-DMIS hanga during creattion 239119 - Creating auto circle features using box select in the Graphics Display window creates circles with the same feature ID 239142 - IPD file is not consistent: Remove ‘measured height’ property for the round slot 239582 - With a disabled SW DCI license we can still select wireframe/point geometry 239609 - AutoCircle: Need to be able to solve during learn mode with a Single Point 239698 - Need to execute a COPOPER/EXPORT command to get the output, Apply does nothing 239714 - Vision probe offset processing corrupts the part program 239742 - Existing copoper commands are available and executable without Cop option in the lock 239758 - Several auto features are missing the Display Hits and Show Details options in summary mode. 239764 - The report dimension colors do not match the edit window colors 239792 - Sheffield controller with Tesa Star M auto Sphere out of memory error message 239798 - Icons are split, incorrectly aligned on layout bar 239894 - It's impossible to assign specific CAD features to a layer 240126 - AutoRoundSlot: Laser: Array not large enough causing crash 240444 - Command mode does not show print options for form 240781 - Loading a contact probe after a vision probe, will not be animated on the cad during execution 240872 - AutoCone: dragging hits problem 240908 - Problem with the list of the features in the FCF dialog box 240946 - AutoRoundSlots: Should not be able to drag hits off the surface 241013 - AutoCircle: Single-Click selection of arcs, AngleVector causing problems 241210 - RunTime Debug - using uninitialized variable if you change illumination following a bad calibration 241280 - The field of the type of Tool Changer should be longer 241343 - AutoNotch: feature dialog: ‘0’ is missing as item in the combo boxes for the sample hits 241409 - Metronics device driver is sometimes not installed 241506 - CAD detection within Find Nominals tolerance fails when no CAD is imported 241540 - Radial auto plane: Need to be able to select '1' as row number in the 'row' control of the probe toolbox 241674 - Spacing is not consistent between dimensions on TextReportingObject when "Use Text Mode Dimension Reporting" is checked. 241704 - AutoSurfacePt: Copy/Paste, thickness value lost 241722 - Marking and block executing a constructed Cop offset point results in an empty pointcloud 241818 - Ctrl+E doesn't work for COP and COPOPER commands 241904 - Add support for more than three cad element types for the autofeatures 241913 - Readouts window is defaulting to only having two fields on by default - Mag and Hits 241975 - Constructing a set with PNT[1..6] get_inputs() returns individual PNTs plus CPCDsearch_id for the set so have 7 inputs 242022 - ReadPosUpdatesXYZEvenIfRMeas=False doesn't seem to be working right 242169 - No indication is given of illumination gray scale / intensity 242192 - Vector/Surface Point with CAD using Find Noms and joysticking to learn feature finds incorrect nominal 242252 - cadonly.rtp produces black and white output after page 10 242330 - IP Defaut File: Can't select thickness type NONE in the IPD file 242395 - Probe tip is not the same as when you select View/Settings from the toolbar 242468 - The probe is no longer displayed for all AutoFeatures types while creating features 242477 - EdgePoint: Target coordinates are converting to 0,0,0 on import of a v4.1 program. 242544 - PC-DMIS crashes when importing IGES file 242591 - Laser Flush & Gap missing TARG coords 242595 - Save As version 3.5 does not save the CAD 242626 - Cursor - Cross not working 242753 - Perpendicularity tolerance is being converted to metric in the report, even though the dimension is being set in inches 242808 - Markings do not update in Summary Mode when clicking a marked set button/icon 242865 - labels are displayed bigger with V3.7 than with in V 3.25 242886 - Wrong vector on measured cicle hits 243127 - Proessing the ReadPos button (in the Move To dialog) successive times adds 3 to the Z value 243305 - Hit data not appearing in RTF file 243504 - Unable to add FORM command by automation 243998 - Equate Alignment not working as expected. 244382 - AutoCircle: View perp and normal for Arc Stud zooms in too close. 244388 - AutoLine/AutoAnglePt: 'from Feature' Offset Moves result in collision 244391 - AutoWrist selection incorrect for 4 AF types, collision possible with 2 244405 - Cells not merging properly in report window 244760 - Cannot create vector points on the attached Catia 4 model file 244769 - Variable names are overwritten by default values in Assignment dialog box 244909 - Need to be able to resize the input window when docking the Probe toolbox 245038 - AutoLine: Depth should be utilized in AvoidanceMoves 245056 - Cannot select autofeature vector points on translated step file 245243 - Step files not allowing for seprate entities 245956 - Leader lines for FCF dimensions in graphics window break down under Automatic Label Positioning. 246008 - Status window must store its size 246080 - Surface is missing in DCT file but present in DCI 246107 - Copious data element does not show its XYZ/IJK values in CAD Info 246223 - DES file problems 246224 - Strange results from alignment 246392 - Improve the speed of the PC-DMIS to Excel wizard 246454 - Inserting specified constraints alignment command fails 246617 - Reference features are lost in the part program 246864 - LSP-X3t not nulled after tool change 246902 - Flatness Per area data truncated in PPAP report 246965 - Exporting as an iges file, polygons are now circles 246980 - Missing the 'ending offset' on the cylinder in the IP Defaults file 247003 - CAD Transform: Specify Rotation Matrix does not work as specified 247066 - Datum constraining of a plane producing bad results 247277 - Perceptron/Metris and Vision Live Views don't work nicely side by side 247341 - IGES File Import Problems 247353 - Activating a secondary axis in an Imported Catia 5 PRODUCT yields incorrect results 247359 - AutoSlot: Can’t switch off the UsePin option on auto slots 247385 - Cant Click on some surfaces from a Catia or step CAD model, when Alternate Iges Import is set to false in the settings editor 247396 - "Page Width" does not scale to the full page width if landcape 247451 - View Path Lines shows vectors in Z for XY plane probing 247452 - AutoCircle: Incorrect diameter calculation 247542 - Wireframe not tied to rest of ProE model 247567 - 2D Profile Edge Trace doesn't show all the measured points 247618 - Most circles on new HexagonDemoSlide are treated as 180 degree arcs, not the full circles 247624 - Program pauses without error when doing a READPOS 247672 - Crash with invalid #BMP in logo.dat 247761 - The messages for operator (Operator Comments) are repeated without motive 247827 - Home positions taken anywhere after timeout 247875 - Communication error: Wrong parameters in the file ISO - 10360-4 248057 - Auto Cone: Creating an autofeature from automation basic script causes incorrect hits 248080 - Part program hangs when performing simultaneous expression and underlying input commands have been executed 248465 - When contact autofeatures are called, the pathlines are drawn 3 times 248468 - Error: "CAD file could not be read..." 248536 - Pin vector for slots is missing in the IPD file 248537 - Number of sample hits for slots is not used 248648 - Create a circle with scan minimum doesn't work with profile 2D : construct a circle with scan is working! 248674 - Support importing IP plans by reference 248770 - AutoCylinder Stud: stylus collision when using ReadPos with no sample hits 248772 - Wrong nominals from CAD when EDGE POINT ONLY function is activated 248774 - AutoEllipse: Erred distribution of the hits on the plane 248830 - Wrist orientations are not saved per machine 248919 - No difference in actual vectors between LEAST_SQR, MIN_CIRCSC and MAX_INSC constructed cylinders 248999 - Calculate Curve Length 249008 - No default curve type creating a LinearOpen scan with Perceptron 249170 - Arm1 probe file has 150MB, arm2 probe file is 30MB 249488 - Hit coordinates on the Hit Targets tab deos not always reflect the currently active alignment 249845 - Problem constructing cylinder from 3 scans to points 239580 - It takes longer to re-load a previously loaded model? 247122 - Optics Calibration Fails on CMM-V 249060 - If the auto focus fails during the optical calibration (FOV Rectangles) the calibration continues without reporting an error 249596 - Selection of labels must be type depending (change only defined) 248259 - etool issue with inspection direction 249828 - The calibration tool 'Ring' is not available 250123 - Simulation of the part program show a move which is not existing in the part program 249859 - Not able to indicate points on certain areas of the attached CAD file 250230 - FOV calibration does not work when selecting ring illumination source 250143 - Serialization error opening program - FCF True Position 249573 - Simultaneous evaluation giving serialization error 250379 - Offline indicator on status bar misleading - says offline even if online 247805 - None of the dimensions created from an IP Translation appear in any of the reports (standard and others) STAT is the default option for dimensions. in the IPD file. 250829 - Incorrect surface after PRO-E DCT import 250694 - PC-DMIS crashes when constructing a plane from constructed sets 250349 - The path lines have collisions with the probe hardware when doing optimize and then auto path 250351 - Ordering of features not logical for on feature (vector point) 250687 - Perimeter Scan Flips vectors 243718 - There is no notification if license server has invalid license file for install 243376 - Use of CMMI.DLL as name of CMM controller (e.g. LEITZ) for CMM-V is causing problems on demo locks 251420 - The "Show Measured Points Toggle" button doesn't update the Graphic Display window 249574 - Graphical evaluation of roundess and flatness GD&T is wrong but fine for corresponding legacy dimensions 251671 - Should not allow calibrate button to be pressed on rotary dialog box, as it doesn't work 251559 - Unable to load DLL ActiveX.ocx message during installation 251582 - Laser Probe Toolbox toggle button still shows if Laser Probe controller is set to NONE 251128 - UID not being translated for FCF or DATUM IP commands 252555 - Exported nominal features do not all match UG prt file in Unigraphics 251577 - Polar coordinates does not produce the correct vector 250674 - VISIO 300 sometimes signals move complete too soon on a SetPosition call that immediately follows a focus 252195 - Perimeter scan path generation produces opposite vector initially but corrects when using F9 and regenerating 249469 - PCDMIS drives probe into tool changer 252331 - Serialization error:Pointcloud loading " Iso 10360-5 Perceptron Multistylus Bridge.PRG " with the current 4.2RC diskset 232525 - Calibrate the Unit for the Arm2 laser produces an application error on the Arm2 computer 253679 - DMIS CONCAT command doesn't import correctly 253839 - BestFit ocx label is too wide now not all information are visible 251381 - PDF-Printing from CAd REPORT shows wrong origin 248903 - Unigraphics Translator model shows irregular surfaces compared with v3.7mr3 243966 - Many of the Tracker Settings pages tabs are not complete 254385 - Single click on a square slot on the Volvo car body returns random square slots numbers 253874 - TESA: FramegrabberInstallerMil80 : Error occured during driver setup ****************************************************************************************************** ******************************************************************************************************